Angel Moctezuma-Ramirez

Dr. Angel Moctezuma-Ramirez

Texas Heart Institute, Houston, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
KLKe Li
Ke Li
CCCristiano de Oliveira Cardoso
Cristiano de Oliveira Cardoso
Angel Moctezuma-RamirezAngel Moctezuma-Ramirez
Angel Moctezuma-Ramirez
AEAbdelmotagaly Elgalad
Abdelmotagaly Elgalad
EPEmerson C. Perin
Emerson C. Perin
Heart rate variability (HRV) is a measurement of the fluctuation of time between each heartbeat and reflects the function of the autonomic nervous system. HRV is an important indicator for both physical and mental status and for broad-scope diseases. In this review, we discuss how wearable devices can be used to monitor HRV, and we compare the HRV monitoring function among different devices. In addition, we have reviewed the recent progress in HRV tracking with wearable devices and its value in health monitoring and disease diagnosis. Although many challenges remain, we believe HRV tracking with wearable devices is a promising tool that can be used to improve personal health.

9 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKe Li
Ke Li
CCCristiano de Oliveira Cardoso
Cristiano de Oliveira Cardoso
Angel Moctezuma-RamirezAngel Moctezuma-Ramirez
Angel Moctezuma-Ramirez
AEAbdelmotagaly Elgalad
Abdelmotagaly Elgalad
EPEmerson C. Perin
Emerson C. Perin
Heart rate variability (HRV) is a measurement of the fluctuation of time between each heartbeat and reflects the function of the autonomic nervous system. HRV is an important indicator for both physical and mental status and for broad-scope diseases. In this review, we discuss how wearable devices can be used to monitor HRV, and we compare the HRV monitoring function among different devices. In addition, we have reviewed the recent progress in HRV tracking with wearable devices and its value in health monitoring and disease diagnosis. Although many challenges remain, we believe HRV tracking with wearable devices is a promising tool that can be used to improve personal health.

24 January 2025 in Science Advances
Verified
Journal Article
Open access
FEFaheem Ershad
Faheem Ershad
ZRZhoulyu Rao
Zhoulyu Rao
SMSushila Maharajan
Sushila Maharajan
FMFernanda Mesquita
Fernanda Mesquita
JHJunkyu Ha
Junkyu Ha
CYCunjiang Yu
Cunjiang Yu
Electrical stimulation of existing three-dimensional bioprinted tissues to alter tissue activities is typically associated with wired delivery, invasive electrode placement, and potential cell damage, minimizing its efficacy in cardiac modulation. Here, we report an optoelectronically active scaffold based on printed gelatin methacryloyl embedded with micro-solar cells, seeded with cardiomyocytes to form light-stimulable tissues. This enables untethered, noninvasive, and damage-free optoelectronic stimulation–induced modulation of cardiac beating behaviors without needing wires or genetic modifications to the tissue solely with light. Pulsed light stimulation of human cardiomyocytes showed that the optoelectronically active scaffold could increase their beating rates (>40%), maintain high cell viability under light stimulation (>96%), and negligibly affect the electrocardiogram morphology. The seeded scaffolds, termed optoelectronically active tissues, were able to successfully accelerate heart beating in vivo in rats. Our work demonstrates a viable wireless, printable, and optically controllable tissue, suggesting a transformative step in future therapy of electrically active tissues/organs.

27 April 2020 in General Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
PDF file
VPVishal Y. Parikh
Vishal Y. Parikh
UPUmang M. Parikh
Umang M. Parikh
Angel Moctezuma-RamirezAngel Moctezuma-Ramirez
Angel Moctezuma-Ramirez
HLHarveen K. Lamba
Harveen K. Lamba
JGJoggy K. George
Joggy K. George
RDReynolds M. Delgado
Reynolds M. Delgado

28 August 2025 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JWJoshua E. Woods
Joshua E. Woods
FAFatima Alrashdan
Fatima Alrashdan
ECEllie C. Chen
Ellie C. Chen
WTWendy Tan
Wendy Tan
MJMathews John
Mathews John
JRJacob T. Robinson
Jacob T. Robinson

6 December 2024 in Science Advances
Verified
Journal Article
Open access
ZRZhoulyu Rao
Zhoulyu Rao
FEFaheem Ershad
Faheem Ershad
YGYing-Shi Guan
Ying-Shi Guan
FMFernanda Mesquita
Fernanda Mesquita
ECErnesto Curty da Costa
Ernesto Curty da Costa
CYCunjiang Yu
Cunjiang Yu
Untethered electrical stimulation or pacing of the heart is of critical importance in addressing the pressing needs of cardiovascular diseases in both clinical therapies and fundamental studies. Among various stimulation methods, light illumination–induced electrical stimulation via photoelectric effect without any genetic modifications to beating cells/tissues or whole heart has profound benefits. However, a critical bottleneck lies in the lack of a suitable material with tissue-like mechanical softness and deformability and sufficient optoelectronic performances toward effective stimulation. Here, we introduce an ultrathin (<500 nm), stretchy, and self-adhesive rubbery bio-optoelectronic stimulator (RBOES) in a bilayer construct of a rubbery semiconducting nanofilm and a transparent, stretchable gold nanomesh conductor. The RBOES could maintain its optoelectronic performance when it was stretched by 20%. The RBOES was validated to effectively accelerate the beating of the human induced pluripotent stem cell–derived cardiomyocytes. Furthermore, acceleration of ex vivo perfused rat hearts by optoelectronic stimulation with the self-adhered RBOES was achieved with repetitive pulsed light illumination.