This article addresses challenges in the design of underground high-voltage transmission lines, focusing on thermal management and cable ampacity determination. It introduces an innovative proposal that adjusts the dimensions of the backfill to enhance ampacity, contrasting with the conventional approach of increasing the core cable’s cross-sectional area. The methodology employs a particle swarm optimization (PSO) technique with adaptive penalization and restart strategies, implemented in MATLAB for parameter autoadaptation. The article emphasizes more efficient solutions than traditional PSO, showcasing improved convergence and precise results (success probability of 66.1%). While traditional PSO is 81% faster, the proposed PSO stands out for its accuracy. The inclusion of thermal backfill results in an 18.45% increase in cable ampacity, considering variations in soil thermal resistivity, backfill properties, and ambient temperature. Additionally, a sensitivity analysis was conducted, revealing conservative values that support the proposal’s robustness. This approach emerges as a crucial tool for underground installation, contributing to continuous ampacity improvement and highlighting its impact on decision making in energy systems.
Técnicas e Instrumentos de Investigación. Diseño y Validación desde la Perspectiva Cuantitativa tiene como propósito responder a las preguntas planteadas por el investigador, además de generar conocimientos, habilidades y destrezas que permitan la selección de los medios idóneos confiables y útiles en el proceso de investigación. Se trata de un texto que puede ser usado como material de apoyo en cursos y seminarios de investigación, así como también, en el apoyo a la labor de tutores y tutorizados, puesto que el mismo ofrece ejercicios y ejemplos que facilitan su comprensión y aplicación en diferentes acciones de recolección y análisis de información.
La presente investigación tuvo como finalidad el desarrollo de un modelo de confiabilidad, disponibilidad y mantenibilidad operacional que permitió el cálculo de disponibilidad y estimaciones de confiabilidad de equipos y sistemas pertenecientes a la planta compresora Jusepín 12 de Petróleos de Venezuela (PDVSA) Compresión Gas Maturín, ubicada en el Complejo Jusepín de PDVSA. El estudio consistió en una investigación de campo, descriptiva, no experimental de tipo proyecto factible. Para el desarrollo del modelo se utilizaron herramientas basadas en el Análisis de Confiabilidad, Disponibilidad y Mantenibilidad (CDM). Para facilitar el manejo del histórico de fallas, se utilizó el software XAMPP (MySQL, PHP, APACHE); para el desarrollo de bases de datos y en el diseño y simulación del modelo se utilizaron los softwares Crystal Ball y Raptor. El resultado fue un modelo que permitió realizar los cálculos de disponibilidad y proyecciones de confiabilidad de la planta, mediante la generación de un número preestablecido de escenarios y la realización de análisis de sensibilidad, que fijó el impacto de cada componente del sistema en los factores de disponibilidad, todo esto como requerimiento para la realización de planes de mantenimiento predictivo.
The objective of this research was to develop a technological architecture proposal that allows for the supervision and control of the operational parameters of gas injection (flow, temperature, and pressure) in a cluster of a high-pressure gas injection plant. The proposal provides a supervision and control system for the HPGIP I high-pressure gas injection plant that includes instrumentation equipment (transmitters and actuators), a remote terminal unit (RTU) as a control device, and the creation of a control logic as the basis for the development of the SCADA GALBA®, through which the operational variables involved in the process of the gas injection plant can be visualized and controlled, allowing the automatic regulation of the flow of gas that enters the deposits. Automatization of the process allows for the elimination of the average error differential that increases from 2 to 5% when the control valve is opened manually. Currently, the MUC-67 and MUC-68 wells that make up cluster 5 require a control valve opening of 20% and 5%, respectively, and this percentage is directly affected by the average valve opening error when performed manually. In addition, there is a savings of around 40 min in the response time by the operators for the adjustment of the opening or closing parameters of the control valve manually. The proposal allows for the different control actions on the variables or parameters of gas injection present in the clump to be carried out from a control room.
El objetivo de la presente investigación fue generar un modelado de confiabilidad, disponibilidad y mantenibilidad de la plataforma de telecomunicaciones y transmisión de datos, que permita el cálculo de la disponibilidad y la estimación de la confiabilidad de los conmutadores (switches), enrutadores (Routers), UPS (sistema de alimentación ininterrumpida), puntos de acceso (Access Point), puntos de acceso/puente (Access point/bridge) y equipos de radio enlace. Se tomó como caso de estudio la localidad de Maturín de Petróleos de Venezuela S.A. (PDVSA). El estudio consistió en una investigación de campo, con nivel descriptivo. La población estuvo constituida por ocho (8) trabajadores del área. Para la obtención de información se utilizó los reportes de fallas del centro de monitoreo de oriente (CIMOR) de los últimos dieciocho (18) meses, de los 106 equipos instalados en Maturín. Para el desarrollo del modelado se utilizó la metodología de análisis confiabilidad, disponibilidad y mantenibilidad (CDM) y el software Raptor 7.0. El modelo propuesto permite realizar los cálculos de disponibilidad y proyecciones de confiabilidad de la plataforma, como requerimiento importante para la realización de planes de mantenimiento y el apoyo en la toma de decisiones para la optimización del funcionamiento operativo de la organización. El modelo propuesto puede ser tomado como ejemplo para las plataformas de telecomunicaciones de cualquiera de las localidades que conforman a PDVSA, sólo realizando un análisis de la configuración y función de los componentes dentro del sistema (Diagrama de bloques de confiabilidad).
Esta investigación tuvo como objetivo desarrollar un sistema automatizado para el control del consumo de glicol regenerado suministrado al sistema de deshidratación del gas natural en la Planta Extracción Jusepín de Petróleos de Venezuela S.A (PDVSA). La planta Jusepín, es una planta de extracción de líquidos del gas natural (LGN) con un (01) tren de proceso y una capacidad de procesamiento de gas de 350 millones de pies cúbicos por día (MMPCD). El estudio consistió en una investigación de campo, con nivel descriptivo y modalidad proyecto factible, donde las técnicas de recolección de datos empleadas fueron la observación directa, entrevistas no estructuradas y la revisión documental. Para el desarrollo del estudio se emplearon las tres (3) primeras fases de la metodología Guía de Gerencia de Proyectos de Inversión Capital (GGPIC). El resultado fue una propuesta para el control automatizado del consumo de Glicol Regenerado suministrado al sistema de Deshidratación del Gas Natural en la Planta Extracción Jusepín, lo cual proporcionará mayor seguridad, precisión, eficiencia y confiabilidad sobre los datos obtenidos en tiempo real, ya que, permitirá visualizar el nivel de glicol y llevar un control del contenido de los recipientes, para mantener el suministro constante de glicol regenerado al sistema y así garantizar que la planta mantenga el proceso de extracción del líquido del gas natural.