Arun-Kumar Kaliya-Perumal

Dr. Arun-Kumar Kaliya-Perumal

Nanyang Technological University, Singapore, Central Singapore, Singapore
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in Spine
Verified
Journal Article
Closed access
WYWei Yuan
Wei Yuan
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
SCSIAW MENG CHOU
SIAW MENG CHOU
JOJacob Oh
Jacob Oh
Study Design.: An experimental laboratory-based biomechanical study. Objective.: To investigate the correlation between cage size and subsidence and to quantify the resistance to subsidence that a larger cage can provide. Summary of Background Data.: The assumption that a bigger interbody cage confers less subsidence has not been proven. There was no previous study that has shown the superiority of lateral cages to bullet cages in terms of subsidence and none that has quantified the correlation between cage size and subsidence. Methods.: A cage was compressed between two standardized polyurethane foam blocks at a constant speed. Four sizes of bullet cages used for transforaminal lumbar interbody fusion (TLIF) and six sizes of lateral cages used for lateral lumbar interbody fusion (LLIF) were tested. The force required for a 5 mm subsidence, axial area of cages, and stiffness were analyzed. Results.: A larger cage required a significantly higher force for a 5 mm subsidence. Longer bullet cages required marginal force increments of only 6.2% to 14.6% compared to the smallest bullet cage. Lateral cages, however, required substantially higher increments of force, ranging from 136.4% to 235.7%. The average force of lateral cages was three times that of bullet cages (6426.5 vs. 2115.9 N), and the average stiffness of the LLIF constructs was 3.6 times that of the TLIF constructs (635.5 vs. 2284.2 N/mm). There was a strong correlation between the axial area of cages and the force for a 5 mm subsidence. Every 1 mm2 increment of axial area corresponded to approximately 8 N increment of force. Conclusion.: Cage size correlated strongly with the force required for a 5 mm subsidence. The LLIF constructs required higher force and were stiffer than the TLIF constructs. Among bullet cages, longer cages only required marginal increments of force. Lateral cages, however, required substantially higher force. Level of Evidence: N/A

17 October 2018 in European Spine Journal
Verified
Journal Article
Open access
PDF file
CLChi-An Luo
Chi-An Luo
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
MLMeng-Ling Lu
Meng-Ling Lu
LCLih-Huei Chen
Lih-Huei Chen
WCWen-Jer Chen
Wen-Jer Chen
CNChi Chien Niu
Chi Chien Niu
Tandem spinal stenosis (TSS) refers to lumbar and cervical spinal canal stenosis. Staged surgery is often chosen, but sometimes, mere decompression of one stenosis is adequate to relieve symptoms. Therefore, we intend to analyze whether starting with the cervical or the lumbar region is the most logical option.

31 December 2019 in Neurospine
Verified
Journal Article
Open access
PDF file
JTJoshua Yuan-Wang Tan
Joshua Yuan-Wang Tan
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
JOJacob Oh
Jacob Oh
We aimed to determine the 2-year mortality and morbidity rates following spine surgery in elderly patients (age ≥80 years) and to study the associated risk factors. The records of patients ≥80 years of age who underwent spine surgery during the years 2003-2015 at Tan Tock Seng Hospital, Singapore were retrospectively reviewed. Information was collected on their demographic characteristics, comorbidities, diagnosis, general and neurological status, type of surgery, and outcomes. The mortality and morbidity rates over a 2-year period were analyzed. Bivariate analyses were carried out to identify factors associated with mortality. We selected 47 patients (mean age, 83.3 years; range, 80-91 years) who were followed up for a mean duration of 27.7 months. The mortality rates at 30 days, 6 months, 1 year, and 2 years following surgery were 2.1%, 8.5%, 10.6%, and 12.8%, respectively. The factors significantly associated with mortality included multiple comorbidities, nondegenerative aetiology, and vertebral fractures. The overall morbidity rate was 48.9%, and 17% of this cohort had major complications. Surgeons should strategize management protocols with due consideration of the mortality and morbidity rates, and be wary of operating on patients with multiple comorbidities, nondegenerative conditions, and vertebral fractures.

27 January 2020 in Global Spine Journal
Verified
Journal Article
Open access
PDF file
GGGerrard Gan
Gerrard Gan
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
CYChun Sing Yu
Chun Sing Yu
CNColum Patrick Nolan
Colum Patrick Nolan
JOJacob Oh
Jacob Oh
Study Design: Retrospective cohort study. Objective: We intend to evaluate the accuracy and safety of cervical pedicle screw (CPS) insertion under O-arm-based 3-dimensional (3D) navigation guidance. Methods: This is a retrospective study of patients who underwent CPS insertion under intraoperative O-arm-based 3D navigation during the years 2009 to 2018. The radiological accuracy of CPS placement was evaluated using their intraoperative scans. Results: A total of 297 CPSs were inserted under navigation. According to Gertzbein classification, 229 screws (77.1%) were placed without any pedicle breach (grade 0). Of the screws that did breach the pedicle, 51 screws (17.2%) had a minor breach of less than 2 mm (grade 1), 13 screws (4.4%) had a breach of between 2 and 4 mm (grade 2), and 4 screws (1.3%) had a complete breach of 4 mm or more (grade 3). Six screws were revised intraoperatively. There was no incidence of neurovascular injury in this series of patients. 59 of the 68 breaches (86.8%) were found to perforate laterally, and the remaining 9 (13.2%) medially. It was noted that the C5 cervical level had the highest breach rate of 33.3%. Conclusions: O-arm-based 3D navigation can improve the accuracy and safety of CPS insertion. The overall breach rate in this study was 22.9%. Despite these breaches, there was no incidence of neurovascular injury or need for revision surgery for screw malposition.

1 September 2020 in Disease Models & Mechanisms
Verified
Journal Article
Open access
PDF file
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
TCTom J. Carney
Tom J. Carney
PIPhilip W. Ingham
Philip W. Ingham
Heterotopic ossification (HO) is a disorder characterised by the formation of ectopic bone in soft tissue. Acquired HO typically occurs in response to trauma and is relatively common, yet its aetiology remains poorly understood. Genetic forms, by contrast, are very rare, but provide insights into the mechanisms of HO pathobiology. Fibrodysplasia ossificans progressiva (FOP) is the most debilitating form of HO. All patients reported to date carry heterozygous gain-of-function mutations in the gene encoding activin A receptor type I (ACVR1). These mutations cause dysregulated bone morphogenetic protein (BMP) signalling, leading to HO at extraskeletal sites including, but not limited to, muscles, ligaments, tendons and fascia. Ever since the identification of the causative gene, developing a cure for FOP has been a focus of investigation, and studies have decoded the pathophysiology at the molecular and cellular levels, and explored novel management strategies. Based on the established role of BMP signalling throughout HO in FOP, therapeutic modalities that target multiple levels of the signalling cascade have been designed, and some drugs have entered clinical trials, holding out hope of a cure. A potential role of other signalling pathways that could influence the dysregulated BMP signalling and present alternative therapeutic targets remains a matter of debate. Here, we review the recent FOP literature, including pathophysiology, clinical aspects, animal models and current management strategies. We also consider how this research can inform our understanding of other types of HO and highlight some of the remaining knowledge gaps.

30 May 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
AKArun-Kumar Kaliya-Perumal
Arun-Kumar Kaliya-Perumal
JCJiun-Ran Charng
Jiun-Ran Charng
CNChi Chien Niu
Chi Chien Niu
TTTsung-Ting Tsai
Tsung-Ting Tsai
PLPo-Liang Lai
Po-Liang Lai
WCWen-Jer Chen
Wen-Jer Chen
The foremost concern of a surgeon during pedicle screw fixation is safety. Assistive modalities, especially intraoperative electromyographic monitoring (EMG) can function as an essential tool to recognize screw malposition that compromise neural integrity, so that the screws can be repositioned immediately rather than later. We intend to study the efficacy of intraoperative EMG monitoring to detect potential pedicle breach and evaluate whether reoperation rates were significantly reduced. Retrospectively, patients who underwent posterior stabilization with pedicle screws for various pathologies were analysed and those with screws among L1-S1 levels were shortlisted. They were divided into two groups. Group 1 included patients in whom trigger EMG (t-EMG) was used to confirm appropriate screw placement and Group 2 included those in whom it was not used. Responses to t-EMG and corresponding stimulation thresholds were recorded for Group 1 patients. The sensitivity and specificity of the test was calculated. Reoperation rates due to postoperative neurologic compromise caused by malpositioned screws were compared between both the groups. A total of 518 patients had 3112 pedicle screws between L1-S1 levels. Among Group 1 [n = 296; Screws = 1856], 145 screws (7.8%) showed a positive response for t-EMG at stimulation thresholds ranging between 2.6 to 19.8 mA. The sensitivity and specificity of t-EMG to diagnose potential pedicle breach was found to be 93.33% and 92.88% respectively. Only one patient among Group 1 required reoperation. However, among Group 2 [n = 222; screws = 1256], six patients required reoperation. This indicated a significant decrease in the number of malpositioned screws that caused neurological compromise [p = 0.02], leading to subsequent decrease in reoperation rates [p = 0.04] among Group 1 patients. Trigger EMG is well efficient in detecting potential pedicle screw breaches that might endanger neural integrity. In combination with palpatory and radiographic assessment, it will certainly aid safe and secure pedicle screw placement. It can also efficiently reduce reoperation rates due to neurologic compromise provoked by a malpositioned screw.