This study compares the influence of two different annuloplasty attachment suture applications, namely the use of an automated fastener versus manually tied knots using a traditional knot pusher, on total operation time, on cardiopulmonary-bypass time and on cross-clamp time, and on short-term outcome. Sixty patients underwent isolated minimally invasive mitral valve repair in Carpentier Type-II mitral disease with implantation of an annuloplasty ring in combination with correction of the prolapsing leaflet using artificial chords. The first 30 patients after implementation of a novel automated fastener were compared with the last 30 patients corrected with a traditional knot pusher. No significant differences with regard to demographic data (age, gender, NYHA class, ejection fraction, BMI, cardiovascular risk factors) between the two groups were found. All patients received isolated mitral valve repair in the first run. Bretschneider HTK was used for cardioplegic cardiac arrest in all patients. Transesophageal and transthoracic echocardiography at the end of operation and at discharge revealed no (n = 25), trace (n = 28) or mild (n = 7) residual regurgitation with no evidence of ring dehiscence and without any significant clinical differences between the groups. Cross-clamp, cardiopulmonary-bypass and total- operation time were significantly reduced in the automated fastener group compared to the group using a traditional knot pusher (87.1 ± 17.9 vs. 101.3 ± 17.8; p < 0.01, 138.1 ± 25.6 vs. 152.7 ± 24.9; p < 0.05, and 203.9 ± 31.02 vs. 223.8 ± 29.01; p < 0.01, respectively). Our short-term results indicate a safe, reliable and fast application of the novel automated fastener device in combination with significant time savings in cardioplegic arrest and cardiopulmonary bypass.
24 June 2015 in European Journal of Medical Research
Definitive fate of the coronary endothelium after implantation of a drug-eluting stent remains unclear, but evidence has accumulated that treatment with rapamycin-eluting stents impairs endothelial function in human coronary arteries. The aim of our study was to demonstrate this phenomenon on functional, morphological and biochemical level in human internal thoracic arteries (ITA) serving as coronary artery model. After exposure to rapamycin for 20 h, functional activity of ITA rings was investigated using the organ bath technique. Morphological analysis was performed by scanning electron microscopy and evaluated by two independent observers in blinded fashion. For measurement of endothelial nitric oxide synthase (eNOS) release, mammalian target of rapamycin (mTOR) and protein kinase B (PKB) (Akt) activation, Western blotting on human mammary epithelial cells-1 and on ITA homogenates was performed. Comparison of the acetylcholine-induced relaxation revealed a significant concentration-dependent decrease to 66 ± 7 % and 36 ± 7 % (mean ± SEM) after 20-h incubation with 1 and 10 μM rapamycin. Electron microscopic evaluation of the endothelial layer showed no differences between controls and samples exposed to 10 μM rapamycin. Western blots after 20-h incubation with rapamycin (10 nM–1 μM) revealed a significant and concentration-dependent reduction of p (Ser 1177)-eNOS (down to 38 ± 8 %) in human mammary epithelial cells (Hmec)-1. Furthermore, 1 μM rapamycin significantly reduced activation of p (Ser2481)-mTOR (58 ± 11 %), p (Ser2481)-mTOR (23 ± 4 %) and p (Ser473)-Akt (38 ± 6 %) in ITA homogenates leaving Akt protein levels unchanged. The present data suggests that 20-h exposure of ITA rings to rapamycin reduces endothelium-mediated relaxation through down-regulation of Akt-phosphorylation via the mTOR signalling axis within the ITA tissue without injuring the endothelial cell layer.
Background. Single-dose cardioplegia is preferred in minimal invasive mitral valve surgery to maintain the adjustment of the operative site without change of preset visualization. The aim of our study was to compare two widely used crystalloid cardioplegias Bretschneider (Custodiol®) versus St. Thomas 2 in patients who underwent mitral valve repair via small anterolateral right thoracotomy. Material and Methods. From May 2012 until February 2019, 184 isolated mitral valve procedures for mitral valve repair via anterolateral right thoracotomy were performed using Bretschneider (Custodiol®) cardioplegia () or St. Thomas (). Primary efficacy endpoint was peak postoperative high-sensitivity cardiac troponin (hs-cTnT) during hospitalization. Secondary endpoints were peak creatine kinase-muscle brain type (CK-MB) and creatine kinase (CK) as well as safety outcomes. We used inverse probability of treatment weighting (IPTW) in order to adjust for confounding by indication. Results. Peak hs-cTnT was higher after use of Bretschneider (Custodiol®) (geometric mean 716 mg/L, 95% confidence interval (CI) 605-847 mg/L) vs. St. Thomas 2 (561 mg/L, CI 467-674 mg/L, ). Peak CK-MB (geometric mean after Bretschneider (Custodiol®): 40 μg/L, CI 35-46, St. Thomas 2: 33 μg/L, CI 27-41, ) and CK (geometric mean after Bretschneider (Custodiol®): 1370 U/L, CI 1222-1536, St. Thomas 2: 1152 U/L, CI 972-1366, ) showed the same pattern. We did not see any difference with respect to postoperative complications between treatment groups after IPTW. Conclusion. Use of St. Thomas 2 cardioplegia was associated with lower postoperative peak levels of all cardiac markers that reflect cardiac ischemia such as hs-cTnT, CK, and CK-MB as compared to Bretschneider (Custodiol®) in propensity-weighted treatment groups.
Background: In isolated mitral valve regurgitation general consensus on surgery is to favor repair over replacement excluding rheumatic etiology or endocarditis. If concomitant aortic valve replacement is performed however, clinical evidence is more ambiguous and no explicit guidelines exist on the choice of mitral valve treatment. Both, double valve replacement (DVR) and aortic valve replacement in combination with concomitant mitral valve repair (AVR + MVP) have been proven to be feasible procedures. In our single-center, retrospective, observational cohort study, we compared the outcome of these two surgical techniques focusing on mortality and morbidity. Methods: 89 patients underwent DVR (n = 41) or AVR + MVP (n = 48) in our institution between 2009 and 2018. Follow-up data was collected using electronic patient records, by contacting treating physicians and by telephone interviews. We used the Kaplan–Meier method to analyze mortality during follow-up and Cox regression to investigate potential predictors of mortality. Results: During a median follow-up duration of 4.5 [IQR 2.9 to 6.1] years, there was no significant difference in mortality between both cohorts. Thirty days mortality was 6.3% in the DVR and 7% in the AVR + MVP cohort. Overall mortality amounted to 17% for DVR and 23% for AVR + MVP. DVR was the preferred procedure for valve disease of rheumatic etiology and for endocarditis, while in degenerative valves AVR + MVP was predominant. More biological valves were used in the AVR + MVP cohort (p < 0.001) and more mechanical valves were implanted in the DVR cohort. The rate of rehospitalization, deterioration of left ventricular ejection fraction and postoperative complications were equally distributed among the two cohorts. Conclusion: Our data analysis showed that both DVR and AVR + MVP are safe and feasible options for double valve surgery. Based on our findings we could not prove superiority of one surgical technique over the other. Choosing the appropriate procedure for the patient should be influenced by valve etiology, patients’ comorbidities and the surgeons’ experience. Trial registration: This was a retrospectively registered trial, registered on April 1st 2018, ClinicalTrials.gov Identifier: NCT03667274.
Engineering functional tissues of clinically relevant size (in mm-scale) in vitro is still a challenge in tissue engineering due to low oxygen diffusion and lack of vascularization. To address these limitations, a perfusion bioreactor was used to generate contractile engineered muscles of a 3 mm-thickness and a 8 mm-diameter. This study aimed to upscale the process to 50 mm in diameter by combining murine skeletal myoblasts (SkMbs) with human adipose-derived stromal vascular fraction (SVF) cells, providing high neuro-vascular potential in vivo. SkMbs were cultured on a type-I-collagen scaffold with (co-culture) or without (monoculture) SVF. Large-scale muscle-like tissue showed an increase in the maturation index over time (49.18 ± 1.63% and 76.63 ± 1.22%, at 9 and 11 days, respectively) and a similar force of contraction in mono- (43.4 ± 2.28 µN) or co-cultured (47.6 ± 4.7 µN) tissues. Four weeks after implantation in subcutaneous pockets of nude rats, the vessel length density within the constructs was significantly higher in SVF co-cultured tissues (5.03 ± 0.29 mm/mm2) compared to monocultured tissues (3.68 ± 0.32 mm/mm2) (p < 0.005). Although no mature neuromuscular junctions were present, nerve-like structures were predominantly observed in the engineered tissues co-cultured with SVF cells. This study demonstrates that SVF cells can support both in vivo vascularization and innervation of contractile muscle-like tissues, making significant progress towards clinical translation.