Krzysztof Maksymiuk

Krzysztof Maksymiuk

Auto-generated profile, based on publicly available information

Krzysztof Maksymiuk


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

27 October 2005 in The Analyst
Verified
Journal Article
Closed access
PDF file
AKAnna Kisiel
Anna Kisiel
HMHonorata Marcisz
Honorata Marcisz
AMAgata Michalska
Agata Michalska
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk
A novel construction of solution free (pseudo)reference electrodes, compatible with all-solid-state potentiometric indicator electrodes, has been proposed. These electrodes use conducting polymers (CP): polypyrrole (PPy) or poly(3,4-ethylenedioxythiophene) (PEDOT). Two different arrangements have been tested: solely based on CP and those where the CP phase is covered with a poly(vinyl chloride) based outer membrane of tailored composition. The former arrangement was designed to suppress or compensate cation- and anion-exchange, using mobile perchlorate ions and poly(4-styrenesulfonate) or dodecylbenzenesulfonate anions as immobilized dopants. The following systems were used: (i) polypyrrole layers doped simultaneously by two kinds of anions, both mobile and immobilized in the polymer layer; (ii) bilayers of polypyrrole with anion exchanging inner layer and cation-exchanging outer layer; (iii) polypyrrole doped by surfactant dodecylbenzenesulfonate ions, which inhibit ion exchange on the polymer/solution interface. For the above systems, recorded potentials have been found to be practically independent of electrolyte concentration. The best results, profound stability of potentials, have been obtained for poly(3,4-ethylenedioxythiophene) or polypyrrole doped by poly(4-styrenesulfonate) anions covered by a poly(vinyl chloride) based membrane, containing both anion- and cation- exchangers as well as solid potassium chloride and silver chloride with metallic silver. Differently to the cases (i)–(iii) these electrodes are much less sensitive to the influence of redox and pH interferences. This arrangement has been also characterized using electrochemical impedance spectroscopy and chronopotentiometry.

1 May 2004 in Journal of Solid State Electrochemistry
Verified
Journal Article
Closed access
PDF file
AMAgata Michalska
Agata Michalska
AGAnna Galuszkiewicz
Anna Galuszkiewicz
MOMagdalena Ogonowska
Magdalena Ogonowska
MOMarcin Ocypa
Marcin Ocypa
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk

14 June 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
DKDawid Kałuża
Dawid Kałuża
EJEwa Jaworska
Ewa Jaworska
MMMaciej Mazur
Maciej Mazur
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk
AAgata Michalska
Agata Michalska

28 September 2020 in Membranes
Verified
Journal Article
Open access
PDF file
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk
ESEmilia Stelmach
Emilia Stelmach
AAgata Michalska
Agata Michalska
Ion-selective membranes, as used in potentiometric sensors, are mixtures of a few important constituents in a carefully balanced proportion. The changes of composition of the ion-selective membrane, both qualitative and quantitative, affect the analytical performance of sensors. Different constructions and materials applied to improve sensors result in specific conditions of membrane formation, in consequence, potentially can result in uncontrolled modification of the membrane composition. Clearly, these effects need to be considered, especially if preparation of miniaturized, potentially disposable internal-solution free sensors is considered. Furthermore, membrane composition changes can occur during the normal operation of sensors—accumulation of species as well as release need to be taken into account, regardless of the construction of sensors used. Issues related to spontaneous changes of membrane composition that can occur during sensor construction, pre-treatment and their operation, seem to be underestimated in the subject literature. The aim of this work is to summarize available data related to potentiometric sensors and highlight the effects that can potentially be important also for other sensors using ion-selective membranes, e.g., optodes or voltammetric sensors.

26 September 2006 in Bioelectrochemistry
Verified
Journal Article
Closed access
AKAnna Kisiel
Anna Kisiel
AMAgata Michalska
Agata Michalska
KMKrzysztof Maksymiuk
Krzysztof Maksymiuk