The demand for groundwater resources in arid and semi-arid regions has increased due to their progressive use in agriculture, industry and domestic activities. Among the difficulties and uncertainties that arise when managing groundwater resources is the calculation of groundwater withdrawals (GWW). The objective of this research work is to review the existing literature on the methods developed to estimate GWW by providing a summary of the advances, limitations and opportunities that the different methods developed on this topic could offer by identifying, categorizing and synthesizing the studies with a focus on developing a systematic guide so that researchers and practitioners conducting GWW studies can be informed of the most popular techniques, and the authors’ experiences in recent years. Therefore, a literature search was conducted in the EEE, Google Scholar, SCOPUS, SpringerLink, ScienceDirect, Taylor & Francis Group and Wiley-Blackwell databases, using the following keywords: Groundwater AND (Withdrawal OR Pumping OR Abstraction) AND (Prediction OR Estimation). Thirty-four journal articles published between 1970 and 2021 were chosen based on the selection criteria, characteristics and capabilities of the approaches used for evaluation in GWW extraction. We concluded that the different methods for groundwater pumping estimation that have been reviewed in this work have advantages and disadvantages in their application. Direct approaches are very old and are still working uncertainty in their application is presented with possible human errors or in the measurement system. On the other hand, indirect methods have evolved along with technological advances, which have brought significant improvements and accuracy to these approaches.
This study presents head losses (hL) and loss coefficients (K) obtained experimentally for schedule 40 PVC pipe elbows, with 90o and 45o in small commercial diameters of ½ to 1½ inches that are commonly used in small networks. The investigation was conducted on a system constructed with short pipes and fittings necessary to measure, direct, and control flow, as well as to evaluate pressure head losses at elbows. Simple water flow was used with rates of 0.342 to 0.980 lps (Q), which generated moderate Reynolds numbers (Re) of 13337 to 80221. It was found that hL showed dependence on the velocity head in all elbows, as well as that hL are greater as the diameter increases for same velocity head. The K values in the elbows tended to be constant when Q > 0.75 lps, but for Q < 0.75 lps the K coefficient increased inversely proportional to Q, becoming larger as the diameter increased. Likewise, the K coefficient tended to increase as Re decreased, while K tended to be constant as Re increased. The results of the experimental coefficient were compared against K values reported in the literature, where significant similarities and discrepancies were found.
28 June 2025 in Journal of Southwest Jiaotong University
This study presents head losses (hL) and loss coefficients (K) obtained experimentally for schedule 40 PVC pipe elbows, with 90° and 45° in small commercial diameters of ½ to 1½ inches that are commonly used in small networks saturated with pipe fittings. The investigation was conducted on a system constructed with short pipes that do not allow flow development, fittings necessary to measure, direct and control flow, as well as to evaluate head losses at the elbows. Simple water flow was used with rates of 0.342 to 0.980 lps (Q), which generated moderate Reynolds numbers (Re) of 13337 to 80221. It was found that hL showed dependence on the velocity head in all elbows, as well as that hL are greater as the diameter increases for the same velocity head. The K values in the elbows tended to be constant when Q > 0.75 lps, but for Q < 0.75 lps the K coefficient increased inversely proportional to Q, becoming larger as the diameter increased. Likewise, the K coefficient tended to increase as Re decreased, while K tended to be constant as Re increased. The results of the experimental coefficient were compared against the K values reported in the literature, where significant similarities and discrepancies were found.