Frank Klont

Dr. Frank Klont


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2018 in Analytical Chemistry
Verified
Journal Article
Open access
FKFrank Klont
Frank Klont
LBLinda Bras
Linda Bras
JWJustina Clarinda Wolters
Justina Clarinda Wolters
SOSara Ongay
Sara Ongay
RBRainer Bischoff
Rainer Bischoff
PHPeter (GRIP) Horvatovich
Peter (GRIP) Horvatovich
For mass spectrometry-based proteomics, the selected sample preparation strategy is a key determinant for information that will be obtained. However, the corresponding selection is often not based on a fit-for-purpose evaluation. Here we report a comparison of in-gel (IGD), in-solution (ISD), on-filter (OFD), and on-pellet digestion (OPD) workflows on the basis of targeted (QconCAT-multiple reaction monitoring (MRM) method for mitochondrial proteins) and discovery proteomics (data-dependent acquisition, DDA) analyses using three different human head and neck tissues (i.e., nasal polyps, parotid gland, and palatine tonsils). Our study reveals differences between the sample preparation methods, for example, with respect to protein and peptide losses, quantification variability, protocol-induced methionine oxidation, and asparagine/glutamine deamidation as well as identification of cysteine-containing peptides. However, none of the methods performed best for all types of tissues, which argues against the existence of a universal sample preparation method for proteome analysis.

1 December 2018 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
Simon D. PouwelsSimon D. Pouwels
Simon D. Pouwels
FKFrank Klont
Frank Klont
Marcel KwiatkowskiMarcel Kwiatkowski
Marcel Kwiatkowski
VWValerie R. Wiersma
Valerie R. Wiersma
AFAlen Faiz
Alen Faiz
NHNick H. T. Ten Hacken
Nick H. T. Ten Hacken

1 May 2020 in Talanta
Verified
Journal Article
Closed access
FKFrank Klont
Frank Klont
SJSandra Jahn
Sandra Jahn
CGChantal Grivet
Chantal Grivet
SKStefan König
Stefan König
RBRon Bonner
Ron Bonner
GHGérard Hopfgartner
Gérard Hopfgartner

1 May 2018 in Talanta
Verified
Journal Article
Open access
FKFrank Klont
Frank Klont
Simon D. PouwelsSimon D. Pouwels
Simon D. Pouwels
JHJos Hermans
Jos Hermans
NMNico C. van de Merbel
Nico C. van de Merbel
PHPeter (GRIP) Horvatovich
Peter (GRIP) Horvatovich
RBRainer Bischoff
Rainer Bischoff
The study of proteins is central to unraveling (patho)physiological processes and has contributed greatly to our understanding of biological systems. Corresponding studies often employ procedures to enrich proteins from their biological matrix using antibodies or other affinity binders coupled to beads with a large surface area and a correspondingly high binding capacity. Striving for maximal binding capacity may, however, not always be required or desirable, for example for proteins of low abundance. Here we describe a simplified immunoprecipitation in 96-well ELISA format (IPE) approach for fast and easy enrichment of proteins. The applicability of this approach for enriching low-abundant proteins was demonstrated by an IPE-based quantitative workflow using liquid chromatography-mass spectrometry (LC-MS) for the soluble Receptor of Advanced Glycation End-products (sRAGE), a promising biomarker in chronic obstructive pulmonary disease (COPD). The method was validated according to U.S. Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines and enabled accurate quantitation of sRAGE between 0.1 and 10 ng/mL in 504 serum. The assay showed substantial correlation with the two most commonly-used sRAGE immunoassays (ELISAs) (R-2-values between 0.7 and 0.8). However, the LC-MS method reported 2-4 times higher sRAGE levels compared to the ELISAs, which is largely due to a suboptimal amount of capturing antibody and/or calibration strategy used by the immunoassays. In conclusion, our simplified IPE approach proved to be an efficient strategy for enriching the low-abundant protein sRAGE from serum and may provide an easy to use platform for enriching other (low abundant) proteins from complex, biological matrices.

13 July 2018 in Journal of Proteome Research
Verified
Journal Article
Open access
FKFrank Klont
Frank Klont
MHMarrit Hadderingh
Marrit Hadderingh
PHPeter (GRIP) Horvatovich
Peter (GRIP) Horvatovich
NHNick H. T. Ten Hacken
Nick H. T. Ten Hacken
RBRainer Bischoff
Rainer Bischoff
Antibodies are indispensable tools in biomedical research, but their size, complexity, and sometimes lack of reproducibility created a need for the development of alternative binders to overcome these limitations. Affimers are a novel class of affinity binders based on a structurally robust protease inhibitor scaffold (i.e., Cystatin A), which are selected by phage display and produced in a rapid and simple E. coli protein expression system. These binders have a defined amino acid sequence with defined binding regions and are versatile, thereby allowing for easy engineering. Here we present an affimer-based liquid chromatography–mass spectrometry (LC–MS) method for quantification of the soluble Receptor of Advanced Glycation End-products (sRAGE), a promising biomarker for chronic obstructive pulmonary disease. The method was validated according to European Medicines Agency and U.S. Food and Drug Administration guidelines and enabled quantitation of serum sRAGE between 0.2 and 10 ng/mL. Comparison between the affimer-based method and a previously developed, validated antibody-based method showed good correlation (R2 = 0.88) and indicated that 25% lower sRAGE levels are reported by the affimer-based assay. In conclusion, we show the first-time application of affimers in a quantitative LC–MS method, which supports the potential of affimers as robust alternatives to antibodies.

1 May 2018 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
KBKees J. Bronsema
Kees J. Bronsema
FKFrank Klont
Frank Klont
FSFrank B. Schalk
Frank B. Schalk
RBRainer Bischoff
Rainer Bischoff
IKIdo P. Kema
Ido P. Kema
NMNico C. van de Merbel
Nico C. van de Merbel
Background: Insulin-like growth factor 1 (IGF1) is a biomarker with various applications in medicine and also in doping control. Methods: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed that employs 15N-IGF1 as an internal standard. The method features urea-based IGF1/IGFBP-complex dissociation which is directly followed by tryptic digestion. Following solid-phase extraction (SPE) sample clean-up of the digest, IGF1 is detected by means of two signature peptides that enable quantification of total IGF1 as well as discrimination between IGF1 proteoforms with ‘native’ and modified or extended N-terminal sequences. Results: Our method is capable of measuring plasma IGF1 concentrations over the clinically relevant range of 10–1000 ng/mL and was validated according to regulatory guidelines. Comparison with the IDS-iSYS IGF1 immunoassay revealed good correlation (R2>0.97) and no proportional bias between both assays was observed after normalizing the results against the WHO reference standard for IGF1 (02/254). Evaluation of several commercially available IGF1 preparations showed varying responses which were due to inconsistencies in purity and absolute amount of IGF1 present in these products. Conclusions: Our LC-MS/MS method introduces urea-based dissociation of IGF1/IGFBP-complexes to enable reliable quantification of IGF1 in plasma. Furthermore, the method is able to detect clinically relevant IGF1 levels without an enrichment procedure at the protein-level and thereby minimizes the risk of losing IGF1 proteoforms during sample preparation.