ANDRES FABIAN QUIROGA SOTO

Dr. ANDRES FABIAN QUIROGA SOTO

Institute of Photonic Sciences, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
SJSergio Luiz Novi Junior
Sergio Luiz Novi Junior
EFEdwin Johan Forero
Edwin Johan Forero
JSJose Angel Ivan Rubianes Silva
Jose Angel Ivan Rubianes Silva
NSNicolas Gabriel S. R. de Souza
Nicolas Gabriel S. R. de Souza
GMGiovani Grisotti Martins
Giovani Grisotti Martins
Rickson C. MesquitaRickson C. Mesquita
Rickson C. Mesquita
As functional near-infrared spectroscopy (fNIRS) is developed as a neuroimaging technique and becomes an option to study a variety of populations and tasks, the reproducibility of the fNIRS signal is still subject of debate. By performing test–retest protocols over different functional tasks, several studies agree that the fNIRS signal is reproducible over group analysis, but the inter-subject and within-subject reproducibility is poor. The high variability at the first statistical level is often attributed to global systemic physiology. In the present work, we revisited the reproducibility of the fNIRS signal during a finger-tapping task across multiple sessions on the same and different days. We expanded on previous studies by hypothesizing that the lack of spatial information of the optodes contributes to the low reproducibility in fNIRS, and we incorporated a real-time neuronavigation protocol to provide accurate cortical localization of the optodes. Our proposed approach was validated in 10 healthy volunteers, and our results suggest that the addition of neuronavigation can increase the within-subject reproducibility of the fNIRS data, particularly in the region of interest. Unlike traditional approaches to positioning the optodes, in which low intra-subject reproducibility has been found, we were able to obtain consistent and robust activation of the contralateral primary motor cortex at the intra-subject level using a neuronavigation protocol. Overall, our findings support the hypothesis that at least part of the variability in fNIRS cannot be only attributed to global systemic physiology. The use of neuronavigation to guide probe positioning, as proposed in this work, has impacts to longitudinal protocols performed with fNIRS.

28 April 2020 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
RFRodrigo M. Forti
Rodrigo M. Forti
MKMarilise Katsurayama
Marilise Katsurayama
JMJulien Menko
Julien Menko
LVLenise Valler
Lenise Valler
ANDRES FABIAN QUIROGA SOTOANDRES FABIAN QUIROGA SOTO
ANDRES FABIAN QUIROGA SOTO
RMRickson C. Mesquita
Rickson C. Mesquita
Prevention of secondary damage is an important goal in the treatment of severe neurological conditions, such as major head trauma or stroke. However, there is currently a lack of non-invasive methods for monitoring cerebral physiology. Diffuse optical methods have been proposed as an inexpensive, non-invasive bedside monitor capable of providing neurophysiology information in neurocritical patients. However, the reliability of the technique to provide accurate longitudinal measurement during the clinical evolution of a patient remains largely unaddressed. Here, we report on the translation of a hybrid diffuse optical system combining frequency domain diffuse optical spectroscopy (FD-DOS) and diffuse correlation spectroscopy (DCS) for real-time monitoring of cerebral physiology in a neuro intensive care unit (neuro-ICU). More specifically, we present a case study of a patient admitted with a high-grade aneurysmal subarachnoid hemorrhage, who was monitored throughout hospitalization. We show that the neurophysiological parameters measured by diffuse optics at the bedside are consistent with the clinical evolution of the patient at all the different stages following its brain lesion. These data provide support for clinical translation of DOS/DCS as a useful biomarker of neurophysiology in the neuro-ICU, particularly in locations where other clinical resources are limited.

21 November 2022 in Metabolites
Verified
Journal Article
Open access
PDF file
ANDRES FABIAN QUIROGA SOTOANDRES FABIAN QUIROGA SOTO
ANDRES FABIAN QUIROGA SOTO
SJSergio Luiz Novi Junior
Sergio Luiz Novi Junior
GMGiovani Grisotti Martins
Giovani Grisotti Martins
LBLuis Felipe Bortoletto
Luis Felipe Bortoletto
WAWagner Avelar
Wagner Avelar
Rickson C. MesquitaRickson C. Mesquita
Rickson C. Mesquita
Carotid artery stenosis (CAS) is a common vascular disease with long-term consequences for the brain. Although CAS is strongly associated with impaired cerebral hemodynamics and neurodegeneration, the mechanisms underlying hemodynamic impairment in the microvasculature remain unknown. In this work, we employed functional near-infrared spectroscopy (fNIRS) to introduce a methodological approach for quantifying the temporal delay of the evoked hemodynamic response. The method was validated during a vasodilatory task (breath-holding) in 50 CAS patients and 20 controls. Our results suggest that the hemodynamic response to breath-holding can be delayed by up to 6 s in the most severe patients, a significant increase from the median 4 s measured for the control group (p = 0.01). In addition, the fraction of brain regions that responded to the task decreased as the CAS severity increased, from a median of 90% in controls to 73% in the most severe CAS group (p = 0.04). The presence of collateral circulation increases the response to breath-holding and decreases the average time delays across the brain, although the number of communicating arteries alone cannot predict these fNIRS-based hemodynamic variables (p > 0.09). Overall, this work proposes a method to quantitatively assess impaired cerebral hemodynamics in CAS patients.

19 November 2020 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
ANDRES FABIAN QUIROGA SOTOANDRES FABIAN QUIROGA SOTO
ANDRES FABIAN QUIROGA SOTO
MKMarilise Katsurayama
Marilise Katsurayama
GMGiovani Grisotti Martins
Giovani Grisotti Martins
LVLenise Valler
Lenise Valler
AQAndrés Quiroga
Andrés Quiroga
RMRickson C. Mesquita
Rickson C. Mesquita
Neurophysiological monitoring is an important goal in the treatment of neurocritical patients, as it may prevent secondary damage and directly impact morbidity and mortality rates. However, there is currently a lack of suitable non-invasive, real-time technologies for continuous monitoring of cerebral physiology at the bedside. Diffuse optical techniques have been proposed as a potential tool for bedside measurements of cerebral blood flow and cerebral oxygenation in case of neurocritical patients. Diffuse optical spectroscopies have been previously explored to monitor patients in several clinical scenarios ranging from neonatal monitoring to cerebrovascular interventions in adults. However, the feasibility of the technique to aid clinicians by providing real-time information at the bedside remains largely unaddressed. Here, we report the translation of a diffuse optical system for continuous real-time monitoring of cerebral blood flow, cerebral oxygenation, and cerebral oxygen metabolism during intensive care. The real-time feature of the instrument could enable treatment strategies based on patient-specific cerebral physiology rather than relying on surrogate metrics, such as arterial blood pressure. By providing real-time information on the cerebral circulation at different time scales with relatively cheap and portable instrumentation, this approach may be especially useful in low-budget hospitals, in remote areas and for monitoring in open fields (e.g., defense and sports).

17 September 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
ANDRES FABIAN QUIROGA SOTOANDRES FABIAN QUIROGA SOTO
ANDRES FABIAN QUIROGA SOTO
LCLorenzo Cortese
Lorenzo Cortese
MVManish Verma
Manish Verma
PDPeter Dannberg
Peter Dannberg
ITIlias Tachtsidis
Ilias Tachtsidis
Turgut DurduranTurgut Durduran
Turgut Durduran
In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 micro-objectives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio (>4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices.

17 June 2025 in bioRxiv
Verified
Preprint
Open access
ANDRES FABIAN QUIROGA SOTOANDRES FABIAN QUIROGA SOTO
ANDRES FABIAN QUIROGA SOTO
LCLorenzo Cortese
Lorenzo Cortese
MVManish Verma
Manish Verma
PDPeter Dannberg
Peter Dannberg
ITIlias Tachtsidis
Ilias Tachtsidis
Turgut DurduranTurgut Durduran
Turgut Durduran
In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 micro-objetives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio ( > 4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices.