CARMEN JULIA NAVARRO-GOMEZ

Prof. Dr. CARMEN JULIA NAVARRO-GOMEZ


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2024 in Chemosphere
Verified
Journal Article
Open access
DPDiego A. Padilla
Diego A. Padilla
JDJaime Dueñas-Moreno
Jaime Dueñas-Moreno
JMJürgen Mahlknecht
Jürgen Mahlknecht
AMAbrahan Rafael Mora
Abrahan Rafael Mora
MKManish Kumar
Manish Kumar
Prosun BhattacharyaProsun Bhattacharya
Prosun Bhattacharya
The widespread presence of arsenic (As) and fluoride (F-) in groundwater poses substantial risks to human health on a global scale. These elements have been identified as the most prevalent geogenic contaminants in groundwater in northern Mexico. Consequently, this study aimed to evaluate the human health and ecological risks associated with the content of As and F- in the Meoqui-Delicias aquifer, which is in one of Mexico's most emblematic irrigation districts. Concentrations of As and F- were measured in 38 groundwater samples using ICP-MS and ion chromatography, respectively. Overall, these elements showed a similar trend across the aquifer, revealing a positive correlation between them and pH. The concentration of As and F- in the groundwater ranged from 5.3 μg/L to 303 μg/L and from 0.5 mg/L to 8.8 mg/L, respectively. Additionally, the levels of As and F- surpassed the established national standards for safe drinking water in 92% and 97% of samples, respectively. Given that groundwater is used for both agricultural purposes and human activities, this study also assessed the associated human health and ecological risks posed by these elements using Monte Carlo simulation and Species Sensitivity Distribution. The findings disclosed a significant noncarcinogenic health risk associated with exposure to As and F-, as well as an unacceptable carcinogenic health risk to As through water consumption for both adults and children. Furthermore, a high ecological risk to aquatic species was identified for F- and high to medium risks for As in the sampling sites. Therefore, the findings in this study provide valuable information for Mexican authorities and international organizations (e.g., WHO) about the adverse effects that any exposure without treatment to groundwater from this region represents for human health.

15 November 2021 in Journal of Water and Climate Change
Verified
Journal Article
Open access
PDF file
DSDavid Sanchez
David Sanchez
CNCARMEN JULIA NAVARRO-GOMEZ
CARMEN JULIA NAVARRO-GOMEZ
Marusia RenteriaMarusia Renteria
Marusia Renteria
JRJ. F. Rose
J. F. Rose
JNJESUS RUBEN SANCHEZ NAVARRO
JESUS RUBEN SANCHEZ NAVARRO
Groundwater is the main source of water in arid cities where precipitations are low and not evenly distributed. The combined impact of climate variability and intensive human activities has caused a substantial decline in groundwater levels. Understanding the response of groundwater levels to meteorological and anthropogenic factors is a key step to propose water management alternatives. Meteorological and groundwater data were used to design a multi-step approach to assess the influential factors on the groundwater system in the City of Chihuahua, Mexico. The analysis of historical groundwater levels and climate showed a clear increase in meteorological drought, as well as a groundwater abstraction trend since 1986. Rainfall, groundwater recharge, and groundwater level displayed a significant decrease. Overall, the groundwater depth is continuously increasing with a strong correlation with groundwater abstraction. Despite having a significant trend, the changes in land-cover, groundwater recharge, and meteorological drought were not the main factors inducing the decreased level of water in the aquifer. The continuous abstraction of groundwater from 1986 to 2010 has led to a depletion of groundwater levels from 32 to 92 m. The findings of this study lay a foundation for future water resource management in the study area.

25 October 2022 in Agronomy
Verified
Journal Article
Open access
PDF file
FHFederico Felix Hahn
Federico Felix Hahn
SVSalvador Valle-Guadarrama
Salvador Valle-Guadarrama
CNCARMEN JULIA NAVARRO-GOMEZ
CARMEN JULIA NAVARRO-GOMEZ
Water is getting scarce and irrigation practices should become more efficient. Mango orchards require great quantities of water, and policies in developing countries are substituting surface gravity irrigation by pressurized systems. A commercial orchard having mature 25-year-old trees and a 10-year-old HD high-density section were irrigated with micro sprinklers using 100% ETc (crop evapotranspiration) and reduced deficit irrigation treatments of 75% and 50% ETc. Water soil measurements were made with EC-5 probes at 10 and 35 cm in depth to study the effect of the different irrigation treatments. After the 2020 harvest, mature trees were trimmed without achieving pruning severity greater than 1.3. Canopy volume, mango size, fruit yield and water-use efficiency WUE were analyzed during 2020 and 2021. Sporadic storms produced sprinkler watering problems as weeds proliferated within trees. A controller with a fuzzy algorithm optimized orchard management and saved water in trees without decreasing yield and fruit size. It was found that one year after mature trees were trimmed by taking away the larger internal branch, more light penetrated the canopy, increasing yield by 60%; pruning in HD trees presented a yield increase of 5.37%. WUE (water-use efficiency) also increased with pruning and its value increased to 87.6 when the fuzzy controller and the 50% DI treatments were used in mature trees. This value was 260% greater than the one obtained in pruned trees without the controller. HD trees presented a lower WUE and yield per hectare than mature trees.

11 February 2022 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
DSDavid Sanchez
David Sanchez
JNJESUS RUBEN SANCHEZ NAVARRO
JESUS RUBEN SANCHEZ NAVARRO
CNCARMEN JULIA NAVARRO-GOMEZ
CARMEN JULIA NAVARRO-GOMEZ
Marusia RenteriaMarusia Renteria
Marusia Renteria
Cities in developing countries that do not consider water resources as the basis for sustainable growth usually accept intermittent water supply (IWS) as the alternative to satisfy the demand of the population. Networks designed as constant water supply (CWS) operated as IWS hinder a safe and reliable water supply; thus, feasible alternatives to return the operation to CWS are required. This paper presents a methodology based flow/pressure control to accomplish an efficient transformation from an IWS sector to a CWS in the City of Chihuahua, Mexico. The management of pressure at sector entrance and critical supply points leads to successful improvement of service, ensuring water availability with adequate pressure at the peak of demand, as well as reducing the supply of water volume by 58% compared to the sector operated in IWS. The methodology allowed the improvement of decision-making and operating policy for the water operating agency (WOA), fixing service deficiency, avoiding the loss of water volumes, and maintaining competent management control. Nonetheless, resistance to the transition of using automation and setting the volume/pressure consumption based on reliable data persists. The change process will be successful to the extent that the WOA efficiently channels the participation of the personnel.

31 July 2023 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
EHEduardo Hernandez-Samaniego
Eduardo Hernandez-Samaniego
CNCARMEN JULIA NAVARRO-GOMEZ
CARMEN JULIA NAVARRO-GOMEZ
DSDavid Sanchez
David Sanchez
JNJESUS RUBEN SANCHEZ NAVARRO
JESUS RUBEN SANCHEZ NAVARRO
Maintaining a constant flow in a potable water distribution hydraulic system is challenging due to fluctuations caused by changes in user demand and seasonal factors. This study aimed to calculate the coefficients and curves of hourly and daily variation of water demand in the water distribution system of Chihuahua. It is crucial to understand the hydraulic system's behavior during peak demands and assess its capacity. The methodology involved calculating coefficients and curves of variation of demand based on flow data measured at the inlet of various hydrometric sectors using flanged electromagnetic flowmeters of various diameters and models. The results showed that the variation curves and coefficients of water demand are valuable tools for modeling, designing, and operating water networks. Incorporating these curves into hydraulic simulations during the planning and design stage can improve the accuracy of these models and better reflect the network's actual behavior. The proposed method is suitable for application in cities with similar demographic and social characteristics. The study concludes that accurate supply area information for hydrometric sectors is essential in constructing the curves and coefficients of demand variation, which can lead to opportunities for improving water service by informing more effective network design and operation.

5 October 2022 in Water International
Verified
Journal Article
Closed access
DSDavid Sanchez
David Sanchez
CNCARMEN JULIA NAVARRO-GOMEZ
CARMEN JULIA NAVARRO-GOMEZ
Marusia RenteriaMarusia Renteria
Marusia Renteria
JNJESUS RUBEN SANCHEZ NAVARRO
JESUS RUBEN SANCHEZ NAVARRO
A sustainable drinking water system is essential to ensure the availability of water. Efficient management is developed by maintaining a positive and continuous pressure. However, in developing countries, the conception is that a constant water supply is unsustainable and the preferred alternative is to modify to an intermittent water supply. In this paper, a methodology for gradually transforming several sectors to a constant supply to decrease the quantity of water supplied is developed. Network sectorization and pressure management were achieved, indicating that the operation of 19% of the households under this methodology generates 24% of the water-saving of the city.