mijo meter

Dr. mijo meter

Klinički Bolnički Centar Split, Split, Splitsko-Dalmatinska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2021 in Respiratory Medicine Case Reports
Verified
Journal Article
Open access
MMmijo meter
mijo meter
IPIvana Kuzmić Prusac
Ivana Kuzmić Prusac
DGDuška Glavaš
Duška Glavaš
DMDiana Meter
Diana Meter
Amiodarone-induced pulmonary toxicity (AIPT) has a variety of presentations. Amiodarone use has been rarely associated with the development of acute respiratory failure. We present a patient with a history of paroxysmal atrial fibrillation who developed acute respiratory distress syndrome despite taking a low dose of amiodarone and having no risk or precipitating factors. The diagnosis of AIPT was made after drug discontinuation and exclusion of other potential causes. The development of acute respiratory failure due to AIPT is often underdiagnosed and undertreated. Better identification of risk factors and developing appropriate diagnostic tools for risk stratification of patients receiving amiodarone is mandatory.

14 January 2024 in Pathophysiology
Verified
Journal Article
Open access
PDF file
MMmijo meter
mijo meter
Josip Andelo BorovacJosip Andelo Borovac
Josip Andelo Borovac
An electrical storm (ES) is defined as the presence of at least three episodes of sustained ventricular tachycardia or ventricular fibrillation within 24 h. This patient had a previously known arterial hypertension, type II diabetes mellitus, and chronic kidney disease and has presented to the Emergency Department (ED) with symptoms of retrosternal chest pain lasting for several hours prior. The initial 12-lead electrocardiogram revealed ST segment elevation in the anterior leads (V1–V6). Emergent coronary angiography revealed an acute occlusion of the proximal left anterior descending artery (pLAD) and percutaneous coronary intervention was performed with successful implantation of one drug-eluting stent in the pLAD. On day 8 of hospitalization, the patient developed a refractory ES for which he received 50 DC shocks and did not respond to multiple lines of antiarrhythmic medications. Due to a failure of medical therapy, we decided to implant a temporary pacemaker and initiate ventricular overdrive pacing (VOP) that was successful in terminating ES. Following electrical stabilization, the patient underwent a successful ICD implantation. This case demonstrates that VOP can contribute to hemodynamic and electrical stabilization of a patient that suffers from refractory ES and this treatment modality might serve as a temporary bridge to ICD implantation.

10 September 2021 in Int. Journal of Clinical Pharmacology and Therapeutics
Verified
Journal Article
Closed access
MMmijo meter
mijo meter
IGIvana Gavran
Ivana Gavran
DBDiana Bajo
Diana Bajo
DDDarko Duplancic
Darko Duplancic
Background: Fluoropyrimi-dines 5-fluorouracil (5-FU) and capecitabine are antimetabolite drugs used for the treat-ment of colorectal, breast, head, and neck malignancies. Different clinical manifesta-tions of fluoropyrimidine-induced cardio-toxicity (FIC) have been reported in the lit-erature. Case report: A 46-year-old female patient with a history of colorectal adenocar-cinoma presented to the Emergency Depart-ment due to chest pain and mildly elevated cardiac serum troponin levels. Three days earlier, she had received a first adjuvant che-motherapy treatment with oral capecitabine. After the exclusion of obstructive coronary artery disease (CAD), acute myopericarditis was suspected. Conclusion: Capecitabine-induced myopericarditis is an extremely rare but important clinical condition to be recog-nized and treated promptly in order to pre -vent potentially lethal consequences of car-diac dysfunction.

10 January 2023 in Reviews in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
MMmijo meter
mijo meter
OBOgnjen Barcot
Ognjen Barcot
IJIrena Jelicic
Irena Jelicic
IGIvana Gavran
Ivana Gavran
ISIvan Skopljanac
Ivan Skopljanac
MIMirela Pavicic Ivelja
Mirela Pavicic Ivelja
Background: The need for computed tomography pulmonary angiography (CTPA) to rule out pulmonary embolism (PE) is based on clinical scores in association with D-dimer measurements. PE is a recognized complication in patients with SARS-CoV-2 infection due to a pro-thrombotic state which may reduce the usefulness of preexisting pre-test probability scores. Aim: The purpose was to analyze new clinical and laboratory parameters while comparing existing and newly proposed scoring system for PE detection in hospitalized COVID-19 patients (HCP). Methods: We conducted a retrospective study of 270 consecutive HCPs who underwent CTPA due to suspected PE. The Modified Wells, Revised Geneva, Simplified Geneva, YEARS, 4-Level Pulmonary Embolism Clinical Probability Score (4PEPS), and PE rule-out criteria (PERC) scores were calculated and the area under the receiver operating characteristic curve (AuROC) was measured. Results: Overall incidence of PE among our study group of HCPs was 28.1%. The group of patients with PE had a significantly longer COVID-19 duration upon admission, at 10 vs 8 days, p = 0.006; higher D-dimer levels of 10.2 vs 5.3 μg/L, p < 0.001; and a larger proportion of underlying chronic kidney disease, at 16% vs 7%, p = 0.041. From already established scores, only 4PEPS and the modified Wells score reached statistical significance in detecting the difference between the HCP groups with or without PE. We proposed a new chronic kidney disease, D-dimers, 10 days of illness before admission (CDD-10) score consisting of the three aforementioned variables: C as chronic kidney disease (0.5 points if present), D as D-dimers (negative 1.5 points if normal, 2 points if over 10.0 μg/L), and D-10 as day-10 of illness carrying 2 points if lasting more than 10 days before admission or 1 point if longer than 8 days. The CDD-10 score ranged from –1.5 to 4.5 and had an AuROC of 0.672, p < 0.001 at cutoff value at 0.5 while 4PEPS score had an AuROC of 0.638 and Modified Wells score 0.611. The clinical probability of PE was low (0%) when the CDD-10 value was negative, moderate (24%) for CDD-10 ranging 0–2.5 and high (43%) when over 2.5. Conclusions: Better risk stratification is needed for HCPs who require CTPA for suspected PE. Our newly proposed CDD-10 score demonstrates the best accuracy in predicting PE in patients hospitalized for SARS-CoV-2 infection.

1 April 2019 in Cardiologia Croatica
Verified
Journal Article
Closed access
JKJosip Katic
Josip Katic
MMmijo meter
mijo meter
AMAntonia Melada
Antonia Melada
IMIvona Mustapic
Ivona Mustapic
VLViktoria Lišnić
Viktoria Lišnić
DBDarija DARIJA BAKOVIĆ Bakovic
Darija DARIJA BAKOVIĆ Bakovic

19 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
MMmijo meter
mijo meter
Josip Andelo BorovacJosip Andelo Borovac
Josip Andelo Borovac
Electrical storm (ES) is defined as the presence of at least three episodes of sustained ventricular tachycardia or ventricular fibrillation within 24 hours. This patient had a previously known arterial hypertension, type II diabetes mellitus, and chronic kidney disease and has presented to the Emergency Department (ED) with symptoms of retrosternal chest pain lasting for several hours prior. The initial 12-lead electrocardiogram revealed ST segment elevation in the anterior leads (V1-V6). Emergent coronary angiography revealed an acute occlusion of the proximal left anterior descending artery (pLAD) and percutaneous coronary intervention was performed with successful implantation of one drug-eluting stent in the pLAD. On the day 8 of hospitalization, patient developed a refractory ES for which he received 50 DC shocks and did not respond to multiple lines of antiarrhythmic medications. Due to a failure of medical therapy, we decided to implant a temporary pacemaker and initiate ventricular overdrive pacing (VOP) that was successful in terminating ES. Following electrical stabilization, the patient underwent a successful ICD implantation. This case demonstrates that VOP can contribute to hemodynamic and electrical stabilization of a patient that suffers from refractory ES and this treatment modality might serve as a temporary bridge to ICD implantation.