Manuel Birlo

Manuel Birlo

Auto-generated profile, based on publicly available information

Manuel Birlo


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Medical Image Analysis
Verified
Journal Article
Open access
MBManuel Birlo
Manuel Birlo
PEP.J. Eddie Edwards
P.J. Eddie Edwards
MCMatthew Clarkson
Matthew Clarkson
DSDanail Stoyanov
Danail Stoyanov
This article presents a systematic review of optical see-through head mounted display (OST-HMD) usage in augmented reality (AR) surgery applications from 2013 to 2020. Articles were categorised by: OST-HMD device, surgical speciality, surgical application context, visualisation content, experimental design and evaluation, accuracy and human factors of human-computer interaction. 91 articles fulfilled all inclusion criteria. Some clear trends emerge. The Microsoft HoloLens increasingly dominates the field, with orthopaedic surgery being the most popular application (28.6%). By far the most common surgical context is surgical guidance (n=58) and segmented preoperative models dominate visualisation (n=40). Experiments mainly involve phantoms (n=43) or system setup (n=21), with patient case studies ranking third (n=19), reflecting the comparative infancy of the field. Experiments cover issues from registration to perception with very different accuracy results. Human factors emerge as significant to OST-HMD utility. Some factors are addressed by the systems proposed, such as attention shift away from the surgical site and mental mapping of 2D images to 3D patient anatomy. Other persistent human factors remain or are caused by OST-HMD solutions, including ease of use, comfort and spatial perception issues. The significant upward trend in published articles is clear, but such devices are not yet established in the operating room and clinical studies showing benefit are lacking. A focused effort addressing technical registration and perceptual factors in the lab coupled with design that incorporates human factors considerations to solve clear clinical problems should ensure that the significant current research efforts will succeed.

29 December 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MBManuel Birlo
Manuel Birlo
EEEddie Edwards
Eddie Edwards
Soojeong YooSoojeong Yoo
Soojeong Yoo
BDBrian Dromey
Brian Dromey
FVFrancisco Vasconcelos
Francisco Vasconcelos
DSDanail Stoyanov
Danail Stoyanov
Obstetric ultrasound (US) training teaches the relationship between foetal anatomy and the viewed US slice to enable navigation to standardised anatomical planes (head, abdomen and femur) where diagnostic measurements are taken. This process is difficult to learn, and results in considerable inter-operator variability. We propose the CAL-Tutor system for US training based on a US scanner and phantom, where a model of both the baby and the US slice are displayed to the trainee in its physical location using the HoloLens 2. The intention is that AR guidance will shorten the learning curve for US trainees and improve spatial awareness. In addition to the AR guidance, we also record many data streams to assess user motion and the learning process. The HoloLens 2 provides eye gaze, head and hand position, ARToolkit and NDI Aurora tracking gives the US probe positions and an external camera records the overall scene. These data can provide a rich source for further analysis, such as distinguishing expert from novice motion. We have demonstrated the system in a sample of engineers. Feedback suggests that the system helps novice users navigate the US probe to the standard plane. The data capture is successful and initial data visualisations show that meaningful information about user behaviour can be captured. Initial feedback is encouraging and shows improved user assessment where AR guidance is provided.

3 October 2024
Verified
Book Chapter
Closed access
PDF file
MBManuel Birlo
Manuel Birlo
RCRazvan Caramalau
Razvan Caramalau
PEPhilip J. “Eddie” Edwards
Philip J. “Eddie” Edwards
BDBrian Dromey
Brian Dromey
MCMatthew J. Clarkson
Matthew J. Clarkson
DSDanail Stoyanov
Danail Stoyanov

12 July 2024 in arXiv
Verified
Preprint
Open access
PDF file
MBManuel Birlo
Manuel Birlo
RCRazvan Caramalau
Razvan Caramalau
PEPhilip J. Eddie Edwards
Philip J. Eddie Edwards
BDBrian Dromey
Brian Dromey
MCMatthew J. Clarkson
Matthew J. Clarkson
DSDanail Stoyanov
Danail Stoyanov
We present HUP-3D, a 3D multi-view multi-modal synthetic dataset for hand-ultrasound (US) probe pose estimation in the context of obstetric ultrasound. Egocentric markerless 3D joint pose estimation has potential applications in mixed reality based medical education. The ability to understand hand and probe movements programmatically opens the door to tailored guidance and mentoring applications. Our dataset consists of over 31k sets of RGB, depth and segmentation mask frames, including pose related ground truth data, with a strong emphasis on image diversity and complexity. Adopting a camera viewpoint-based sphere concept allows us to capture a variety of views and generate multiple hand grasp poses using a pre-trained network. Additionally, our approach includes a software-based image rendering concept, enhancing diversity with various hand and arm textures, lighting conditions, and background images. Furthermore, we validated our proposed dataset with state-of-the-art learning models and we obtained the lowest hand-object keypoint errors. The dataset and other details are provided with the supplementary material. The source code of our grasp generation and rendering pipeline will be made publicly available.