Supriya Khadka

Supriya Khadka

Auto-generated profile, based on publicly available information

Supriya Khadka


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
SKSupriya Khadka
Supriya Khadka
Hom Bahadur RijalHom Bahadur Rijal
Hom Bahadur Rijal
AKAMANO KATSUNORI
AMANO KATSUNORI
TSTeruyuki Saito
Teruyuki Saito
HIHikaru Imagawa
Hikaru Imagawa
MTMori Taro
Mori Taro
Comfort temperature is important to investigate because the chosen office indoor temperatures affect the energy used in a building, and a thermally comfortable environment makes the occupants be more productive. The effects of temperature on comfort are broadly recognized for thermal comfort. Japanese office buildings are well equipped with air-conditioning systems to improve the thermal comfort of the occupants. The main objectives of this research were to compare the winter comfort temperature in mixed mode (MM) and heating, ventilation and air-conditioning (HVAC) office buildings and to investigate the relationship between the comfort temperature and the indoor air temperature. This study measured the thermal environmental conditions of the office buildings and surveyed the thermal comfort of the occupants. The field survey was conducted during winter in seven office buildings located in the Aichi prefecture of Japan. In total, 4466 subjective votes were collected from 46 occupants. The result suggested that the occupants were found to be more satisfied with the thermal environment of MM buildings than that of HVAC office buildings. Overall, 95% of comfort temperatures were in the range 22~28 °C in MM and HVAC buildings, which were higher than the indoor temperature of 20 °C recommended by the Japanese government. The comfort temperature was highly correlated to the indoor air temperature of the MM buildings than to that of HVAC buildings. This indicated that the occupants were more adapted towards the given thermal environment of MM buildings.

31 January 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
NMNokuto Mizutani
Nokuto Mizutani
Hom Bahadur RijalHom Bahadur Rijal
Hom Bahadur Rijal
NANaja Aqilah
Naja Aqilah
SKSupriya Khadka
Supriya Khadka
As people spend the majority of their time indoors, maintaining a comfortable and suitable thermal environment within buildings is essential for improving quality of life. Previous studies in Japan have investigated the wet-bulb globe temperature (WBGT) in indoor environments; however, studies primarily focused on residential buildings are lacking. Therefore, a field survey of 17 Japanese dwellings was carried out during the summer, for which a total of 1166 thermal sensation votes (TSVs) were collected from 23 respondents. The results show that the average indoor air temperature is 26.4 °C, which is 1.6 °C lower than the recommendation for summer temperature by the Japanese government. The variation in globe temperature and WBGT indicates that there are significant differences in cooling usage behavior, with a strong correlation between WBGT and indoor globe temperature. The acceptable indoor globe temperature exhibits a wider range in free-running (FR) mode than in cooling (CL) mode. The mean comfort temperature was 26.9 °C in FR mode, while it was 27.0 °C in CL mode. These findings indicate that the occupants felt comfortable at the high indoor temperature, suggesting there is a possibility to reduce the energy used for cooling.

1 January 2024
Verified
Conference Paper
Closed access
SKSupriya Khadka
Supriya Khadka
HRHom Rijal
Hom Rijal
KAKatsunori Amano
Katsunori Amano
TSTeruyuki Saito
Teruyuki Saito
HIHikaru Imagawa
Hikaru Imagawa
TMTaro Mori
Taro Mori