Mrinmoy Sarker Turja

Mr. Mrinmoy Sarker Turja

Electronics Engineering, Kookmin University, Seoul, Republic of Korea
+1
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShama Satter
Shama Satter
Mrinmoy Sarker TurjaMrinmoy Sarker Turja
Mrinmoy Sarker Turja
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Effective management of diabetes requires accurate monitoring of blood glucose levels. Traditional invasive methods for such monitoring can be cumbersome and uncomfortable for patients. In this study, we introduce a noninvasive approach to estimate blood glucose levels using photoplethysmography (PPG) signals. We have focused on blood glucose prediction using wrist PPG signals and explored various PPG waveform-based features, including AC to DC ratio (AC/DC) and intrinsic mode function (IMF)-based features derived from empirical mode decomposition (EMD). To the best of our knowledge, no studies have been found using EMD-based features to estimate blood glucose levels noninvasively. Additionally, feature importance-based selection has also been used to further improve the accuracy of the proposed model. Among the four machine learning algorithms considered in this study, CatBoost consistently outperformed XGBoost, LightGBM, and random forest across a wide number of features. The best performing model, CatBoost, achieved Pearson’s r of 0.96, MSE 0.08, R2 score 0.92, and MAE 8.01 when considering the top 50 features selected from both PPG waveform-based features and IMF-based features. The p-values for all models were <0.001, indicating statistically significant correlations. Overall, this study provides valuable insights into the feasibility and effectiveness of noninvasive blood glucose monitoring using advanced machine learning techniques.

12 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mrinmoy Sarker TurjaMrinmoy Sarker Turja
Mrinmoy Sarker Turja
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
HKHyoungkeun Kim
Hyoungkeun Kim
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Glycated hemoglobin (HbA1c) is the most important factor in diabetes control. Since HbA1c reflects the average blood glucose level over the preceding three months, it is unaffected by a patient’s activity level or diet before a test. Noninvasive HbA1c measurement reduces both the pain and complications associated with fingertip piercing to collect blood. Photoplethysmography is helpful for measuring HbA1c without blood samples. Herein, only two wavelengths (615 and 525 nm) were used to estimate HbA1c noninvasively, where two different ratio calibrations were applied and their performances were compared to a work that used three wavelengths. For the fingertip type, the Pearson’s r values for HbA1c estimates were 0.896 and 0.905, considering the ratio calibrations for the blood vessel and whole finger models, respectively. Using another value (HbA1c) calibration in addition to the ratio calibrations, we could improve this performance such that the Pearson’s r values of the HbA1c levels were 0.929 and 0.930 for the blood vessel and whole finger models, respectively. In a previous study, using three wavelengths, the Pearson’s r values were 0.916 and 0.959 for the blood vessel and whole finger models, respectively. Here, the RCF of the SpO2 estimation was 0.986 when the SpO2 ratio calibration was applied, while in a previous study, the RCF values of the SpO2 estimation were 0.983 and 0.986 for the blood vessel and whole finger models, respectively. Thus, we have shown that HbA1c estimation using only two wavelengths has a comparable performance to previous studies.

24 August 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
SHShifat Hossain
Shifat Hossain
Mrinmoy Sarker TurjaMrinmoy Sarker Turja
Mrinmoy Sarker Turja
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
To diagnose diabetes early or to maintain stable blood glucose levels in diabetics, blood glucose levels should be frequently checked. However, the only way to check blood glucose levels regularly is to use invasive methods, such as pricking the fingertip or using a minimally invasive patch. These invasive methods pose several problems, including being painful and potentially causing secondary infections. This study focuses on noninvasively measuring glycated hemoglobin (HbA1c) using PPG signals. In particular, the study relates to a method and a hardware design technology for removing noise that may be present in a PPG signal due to skin contact with a noninvasive HbA1c measurement device. The proposed HbA1c measurement device consists of the first sensor (PPG sensor) module including an optical barrier and the second sensor (cylindrical sensor) module for removing the skin effect. We have developed a Monte Carlo method to implement accurate, noninvasive HbA1c measurement by considering different skin properties among different subjects. Implementing this model in wearable devices will allow end users to not only monitor their glycated hemoglobin levels but also control diabetes with higher accuracy without needing any blood samples. This will be a groundbreaking advancement in modern wearable medical devices.

26 January 2023
Verified
Book Chapter
Closed access
PDF file
SMSohag Kumar Mondal
Sohag Kumar Mondal
MIMonira Islam
Monira Islam
OFOmar Faruque
Omar Faruque
Mrinmoy Sarker TurjaMrinmoy Sarker Turja
Mrinmoy Sarker Turja
MYMd. Salah Uddin Yusuf
Md. Salah Uddin Yusuf

1 January 2026
Verified
Conference Paper
Closed access
PDF file
Mrinmoy Sarker TurjaMrinmoy Sarker Turja
Mrinmoy Sarker Turja
MPMary Pyfrom
Mary Pyfrom
SASean Aleman
Sean Aleman
TVTristan Valenzuela
Tristan Valenzuela
SSShovan Shakya
Shovan Shakya
APAshwin B Parthasarathy
Ashwin B Parthasarathy
Prefrontal hemodynamics were investigated using a flexible fNIRS device during an adaptive ball-tracking game under single and dual-task conditions. Significant dissociations in HbO and HbT were revealed across difficulty levels, highlighting specific metabolic costs of cognitive interference.