Guillermo Pascual Cisneros

Dr. Guillermo Pascual Cisneros

Institute of Physics of Cantabria, Santander, Cantabria, Spain
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
FCFrancisco Javier Casas
Francisco Javier Casas
PVPatricio Vielva
Patricio Vielva
Cosmic Microwave Background (CMB) B-modes detection is the main focus of future CMB experiments because of the valuable information it contains, particularly to probe the physics of the very early universe. For this reason, we have developed an optimized polarimeter demonstrator sensitive to the 10–20 GHz band in which the signal received by each antenna is modulated into a Near Infrared (NIR) laser by a Mach–Zehnder modulator. Then, these modulated signals are optically correlated and detected using photonic back-end modules consisting of voltage-controlled phase shifters, a 90-degree optical hybrid, a pair of lenses, and an NIR camera. During laboratory tests, a 1/f-like noise signal related to the low phase stability of the demonstrator has been found experimentally. To solve this issue, we have developed a calibration method that allows us to remove this noise in an actual experiment, until obtaining the required accuracy level in the measurement of polarization.

21 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FCFrancisco Javier Casas
Francisco Javier Casas
PVPatricio Vielva
Patricio Vielva
RBR. Belen Barreiro
R. Belen Barreiro
EMEnrique Martinez-Gonzalez
Enrique Martinez-Gonzalez
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of 1550 nm. The instrument was designed to measure the polarization of cosmic microwave background (CMB) radiation from the sky, obtaining the Stokes parameters of the incoming signal simultaneously, in a frequency range from 10 to 20 GHz. A linearly polarized input signal with a variable polarization angle is used as excitation in the polarimeter calibration setup mounted in the laboratory. The polarimeter systematic errors can be corrected with the proposed calibration procedure, achieving high levels of polarization efficiency (low polarization percentage errors) and low polarization angle errors. The calibration method is based on the fitting of polarization errors by means of sinusoidal functions composed of additive or multiplicative terms. The accuracy of the fitting increases with the number of terms in such a way that the typical error levels required in low-frequency CMB experiments can be achieved with only a few terms in the fitting functions. On the other hand, assuming that the calibration signal is known with the required accuracy, additional terms can be calculated to reach the error levels needed in ultrasensitive B-mode polarization CMB experiments.

11 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FCFrancisco Javier Casas
Francisco Javier Casas
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
This paper presents a study of the performances of different Mach–Zehnder modulation technologies with applications in microwave polarimeters based on a near-infrared (NIR) frequency up-conversion stage, allowing for optical correlation and signal detection at a wavelength of 1550 nm. Commercial Mach–Zehnder modulators (MZMs) are traditionally implemented using LiNbO3 technology, which does not enable integration for the fabrication of MZMs. In this work, we propose the use of an alternative technology based on InP, which allows for integration in the fabrication process. In this way, it is possible to obtain advantages in terms of bandwidth, cost, and size reductions, which yield results that are very interesting for wide-band applications such as microwave instrumentation for the study of the cosmic microwave background (CMB). Here, we describe and compare the modulation performances of different MZMs, with one commercial unit presenting a higher bandwidth than those in previous works, and another three InP integrated units provided by the Fraunhofer Institute for Telecommunications, Heinrich-Hertz-Institute (HHI). Then, these modulators were coupled to a microwave polarimeter demonstrator, which has also been presented previously, to compare the polarization measurement performances of each of the MZMs.

6 April 2026 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
AFAlessandro Fasano
Alessandro Fasano
MFMateo Fernández-Torreiro
Mateo Fernández-Torreiro
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
RHRoger John Hoyland
Roger John Hoyland
FCFrancisco Javier Casas
Francisco Javier Casas
JRJ. Alberto Rubiño-Martín
J. Alberto Rubiño-Martín
Context . Polarization measurements in the 30–40 GHz range are essential to improving our understanding of Galactic synchrotron radiation and potential anomalous microwave emissions, and obtaining such measurements will ultimately aid in detecting primordial B modes. To achieve this aim, it is crucial to achieve unprecedented performance in instrumentation. Thus, accurately calibrating instrument responses and the polarization angle represents an essential step in state-of-the-art setups. The modeling and mitigation of systematic effects are also critical in this context. Aims . Our objective is to characterize the QUIJOTE Thirty and Forty GHz instrument (TFGI), calibrate it with a reference calibration signal on the ground, compare our results with on-sky calibration based on bright sources, and study the stability of the calibration parameters over time. Methods . First, from the ground, we fit the data using a reference calibration signal (a diode) introduced to resolve degeneracies among the various instrument angles. Finally, we utilized on-sky observations of Tau A and the Moon to validate the results. Results . By creating calibration datasets obtained with the reference diode, we evaluated the data quality and quantified phase switch errors to account for the fine polarization response. We also utilized Tau A and Moon observations to calibrate the system’s response and stability over time. In addition, we calculated the refraction index of the Moon to be n Moon = 1.209 ± 0.007 (stat) ± 0.009 (sys) at 31 GHz under smooth-surface assumption. Conclusions . The results from fitting the instrument phase-switch error angle align with 0 deg at 2 σ precision, indicating that no further correction is required within a few percent precision. The calibrations with astrophysical sources (Tau A and the Moon) yielded consistent results that constrain the polarization angle and responsivity. The polarization efficiency aligns well with ground measurements and the Tau A characterization, whereas the Moon-based calibration is more affected by systematics. We found hints of responsivity variations over time, although the relative responsivity between channels was found to remain stable. We conclude that installing a live calibrator in the future will enhance the performance of TFGI by continuously monitoring responsivity and in turn improving the mitigation of systematic effects.

26 October 2023 in Inventions
Verified
Journal Article
Open access
PDF file
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
FCFrancisco Javier Casas
Francisco Javier Casas
PVPatricio Vielva
Patricio Vielva
One of the main objectives of cosmology is the measurement of the Cosmic Microwave Background (CMB) polarization and, in particular, the so-called B-modes, which could demonstrate the existence of the primordial gravitational waves generated at the early stages of the Universe. For this reason, a new integrated version of the heterodyne polarimeter photonic part shown on a previously proposed scheme that can be used in both direct imaging and interferometric instruments is presented. We have tested its properties using specific commercial software, obtaining promising results. Working as a direct imaging instrument, it is shown that the proposed polarimeter can provide sufficiently low polarization angle and polarization efficiency systematic errors, which are considered acceptable for current ground-based CMB polarization experiments dedicated to the characterization of the foreground signals affecting the lowest part of the frequency spectrum.

7 May 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
ISIrene Sánchez-Ramos
Irene Sánchez-Ramos
FCFrancisco Javier Casas
Francisco Javier Casas
JCJavier Cubas
Javier Cubas
GCGuillermo Pascual Cisneros
Guillermo Pascual Cisneros
LCLaura Castelló
Laura Castelló
PVPatricio Vielva
Patricio Vielva
The Cosmic Microwave Background (CMB) carries crucial information about the origin and evolution of the Universe, with its polarization patterns providing potential evidence of primordial gravitational waves. Achieving the precision required for these measurements demands highly accurate calibration methods. This study presents the development of a reference signal source to be integrated as the payload of LEO-CalSat, a Low-Earth Orbit satellite designed to serve as an artificial, far-field calibration tool for ground-based CMB polarization experiments. The system aims both to validate the technological readiness of a compact calibration payload for future L2 missions and to provide reference signals in the W-band (75–110 GHz) for current observatories. The calibration source, integrated within the volume of a CubeSat’s 2 U, was designed to balance miniaturization with performance, incorporating key components such as a frequency multiplier with a Voltage-Controlled Oscillator, horn antenna, and polarizer. Laboratory tests demonstrated fully polarized emission with output powers up to 6 dBm and a signal-to-noise ratio of approximately 30 dB, confirming the feasibility of precise polarization calibration. The reduced mass and power consumption (1 kg, 9 W) ensure compatibility with CubeSat constraints. The results validate the core concept and readiness of LEO-CalSat for space operation, representing a significant step toward establishing standardized, space-based calibration for future CMB missions and advancing precision cosmology.