Durmus Alperen Bozkurt

Dr. Durmus Alperen Bozkurt

Endodontics, Necmettin Erbakan University, Konya, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
MAMakbule Bilge Akbulut
Makbule Bilge Akbulut
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
ATArslan Terlemez
Arslan Terlemez
MAMelek Akman
Melek Akman
Akbulut MB, et al. Restor Dent Endod. 2018 Nov;44:e5. https://doi.org/10.5395/rde.2019.44.e5

1 January 2023 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
EBEmine B. Buyukerkmen
Emine B. Buyukerkmen
ATArslan Terlemez
Arslan Terlemez
Purpose: The purpose of this study was to assess the pull-out bond strength (PBS) of endodontically treated anterior teeth that had been restored with monolithic zirconia endocrowns using different extension depths (EDs) and post-and-core crowns after chewing simulation. Methods: Thirty-six maxillary central teeth were used (n = 12). Group I: Glass fiber post-and-core crown, Group II: Endocrown with 3-mm EDs, Group III: Endocrown with 5-mm EDs. Restorations were fabricated from monolithic zirconia blocks using a CAM (computer-aided manufacturing) device. For cementation, conventional resin luting agent (Multilink N) was used. All samples were aged with a chewing simulator and PBS tests were conducted at a speed of 1 mm/min using an electromechanical servo universal testing machine. The values were recorded in MPa by dividing the failure load by the bonding area. One-way ANOVA and the post-hoc Tukey test were used for statistical analysis (P = 0.05). Results: Group III demonstrated significantly greater PBS values than Groups I and II (P = 0.001). No significant difference was found between Groups I and II (P = 0.072). Conclusion: Increasing the ED of an endocrown influences the PBS of endodontically treated anterior teeth restored with monolithic zirconia endocrowns.

22 December 2020 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
ATArslan Terlemez
Arslan Terlemez
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
Objective: The aim of the study was to assessment of technical quality of 9562 endodontic cases treated by heterogeneous groups with different clinical experience. Material and methods: This retrospective study reviewed the dental records of 8590 patients (9562 endodontic cases and 13203 root canals including 3340 retreatment root canals) treated by fourth-year undergraduates, fifth-year undergraduates, endodontic program students, and endodontic specialists between December 2017 and December 2018 at the Department of Endodontics of Necmettin Erbakan University Faculty of Dentistry in Konya. The length, density, and taper of root fillings, the acceptable technical quality of the root filling criteria, and the presence of procedural errors, were recorded. Chi-square tests with a significance level at p=0.05 were used for statistical analysis. Results: Acceptable root fillings were found in 71.5% of endodontic cases. Clinical experience showed statistical differences in the root filling quality among fourth-year undergraduates, fifth-year undergraduates, endodontic program students, and specialists (52, 63.1, 77.9 and 86.5% respectively). Fractured instruments and missed canals were noted in 9.8% and 0.57% of cases treated by endodontic program students significantly more than the other clinical experiences. No statistical differences were found among the clinical experiences in other procedural errors. No statistically significant differences were found between age range and gender in additional root canals. Statistically significant differences were observed between the number of root canal retreatments in terms of age range and gender. Conclusions: Clinical experience affects the technical quality of root canal treatments. Fractured instruments and missed canals, especially by endodontic program students, should be given more attention. KEYWORDS Dental radiography; Education; Undergraduate.

30 April 2023 in International Dental Research
Verified
Journal Article
Open access
PDF file
MAMelek Akman
Melek Akman
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
CZCarla Zogheib
Carla Zogheib
Aim: The aim of this study was to investigate the impact of photon-initiated photoacoustic streaming (PIPS) and ultrasonic activator Ultra X (UX) on the extrusion of debris using the One Curve (OC) rotary system and the Reciproc Blue (RB) system in curved canals. Methodology: Ninety extracted mandibular first molar teeth were divided into six groups (n = 15), Group (1): OC with PIPS, (2) OC with UX, (3) OC with conventional needle irrigation (CNI), (4) RB with PIPS, (5) RB with UX, and (6) RB with CNI. The irrigation activation methods were used in the final irrigation with 2.5 cc of distilled water. The apically protruded debris was collected into pre-weighed Eppendorf tubes. By deducting the tube's initial weight from the final weight, the weight of dry protruded debris was calculated. Two-way ANOVA test was used to analyze the results statistically. Results: A significant difference was found among all groups (p < 0.05). No statistically significant difference was found among the instrumentation systems, regardless of the irrigation technique employed (p > 0.05). The statistically significant difference was found among the PIPS, UX, and CNI irrigation systems, regardless of the rotary systems (p < 0.05). CNI caused significantly less debris extrusion than the UX ultrasonic irrigation activation systems. Conclusion: The UX irrigation activation system caused the highest amount of debris extrusion in curved canals. PIPS can be preferred to ultrasonic devices as irrigation activation systems. How to cite this article: Akman M, Bozkurt DA, Zogheib C. Efficacy of passive ultrasonic activation and photon-initiated photoacoustic streaming on apical extruded debris of different rotary systems in curved canals. Int Dent Res 2023;13(1):13-18. https://doi.org/10.5577/idr.2023.vol13.no1.3 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.

21 August 2023 in Australian Endodontic Journal
Verified
Journal Article
Closed access
AUArzu Yağmur Uçar
Arzu Yağmur Uçar
TKTürkay Kölüş
Türkay Kölüş
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
PRASANNA NEELAKANTANPRASANNA NEELAKANTAN
PRASANNA NEELAKANTAN
Islam Abdelhalim Abdelaziz AliIslam Abdelhalim Abdelaziz Ali
Islam Abdelhalim Abdelaziz Ali
SBSema Belli
Sema Belli

29 December 2025 in Selcuk Dental Journal
Verified
Journal Article
Open access
DBDurmus Alperen Bozkurt
Durmus Alperen Bozkurt
ATArslan Terlemez
Arslan Terlemez
DBDuygu Bozkurt
Duygu Bozkurt
Background/purpose: The aim of the study is to evaluate whether hypochlorous acid (HOCl) has an effect on the dissolution of bovine pulp tissue. Materials and methods: Sixty bovine-pulp-tissue samples were randomly divided into six experimental groups (n=10): Group I- 5.25% sodium hypochlorite (NaOCl), Group II- 2.6% NaOCl, Group III- 1.3% NaOCl, Group IV- HOCl, Group V- 17% Ethylenediaminetetraaceticacid (EDTA), Group VI- Distilled-Water. Pulp samples were immersed in coded solutions in ten minute intervals for the first three-hours, after that they were removed from the solution in sixty-minute intervals. The difference in the weight of the tissue sample was measured before and after the exposure to the test solution, until no weight could be measured with the remaining existing tissue up to a total of one week. The time required for the solutions to dissolve the tissue (min) divided by the initial weight and tissue loss per-minute calculated as mg/min. The data were statistically analyzed using the Kruskal–Wallis and Mann–Whitney U-tests (α=0.05). Results: Showed that a significant tissue dissolution in the chlorine-containing groups (HOCl and NaOCl), while no significant tissue dissolution occurred in distilled water and 17% EDTA groups. There was a significant difference between HOCl and NaOCl solutions (P < 0.001). Conclusion: The results of this study confirmed that eventhough the tissue dissolution rate of HOCl was less than NaOCl, it could completely dissolve the pulp tissue.