Wenya Chen

Wenya Chen

Auto-generated profile, based on publicly available information

Wenya Chen


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Optics Express
Verified
Journal Article
Closed access
WCWenya Chen
Wenya Chen
CLChao Li
Chao Li
DWDong Wang
Dong Wang
WAWei An
Wei An
Song GaoSong Gao
Song Gao
SGShijing Guo
Shijing Guo
A functionally tunable and absorption-tunable terahertz (THz) metamaterial absorber based on vanadium dioxide (VO2) and graphene is proposed and verified numerically. Based on phase transition properties of VO2 and tunability of graphene, the switching performance between ultra-broadband and narrow-band near-perfect absorption can be achieved. We simulate and analyze the characteristics of the constructed model by finite element analysis. Theoretical calculations show that when VO2 is in the metallic state and the graphene Fermi energy is 0 eV, the designed absorber can perform ultra-broadband absorption. The absorber achieves greater than 95% absorption in the 2.85 - 10THz range. When VO2 is in the insulating state and the graphene Fermi energy is 0.7 eV, more than 99.5% absorption can be achieved at 2.3 THz. The absorption rate can be tuned by changing the conductivity of VO2 and the Fermi energy of graphene. Moreover, the proposed absorber displays good polarization insensitivity and wide incident angle stability. The design may have potential applications in terahertz imaging, sensing, electromagnetic shielding and so on.

3 December 2023 in Optical Materials
Verified
Journal Article
Closed access
GWGuozheng Wu
Guozheng Wu
CLChao Li
Chao Li
DWDong Wang
Dong Wang
Song GaoSong Gao
Song Gao
WCWenya Chen
Wenya Chen
JXJiaran Xiong
Jiaran Xiong

22 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
WAWei An
Wei An
CLChao Li
Chao Li
DWDong Wang
Dong Wang
WCWenya Chen
Wenya Chen
SGShijing Guo
Shijing Guo
CZChunwei Zhang
Chunwei Zhang
A compact temperature-refractive index (RI) flat photonic crystal fiber (PCF) sensor based on surface plasmon resonance (SPR) is presented in this paper. Sensing of temperature and RI takes place in the x- and y- polarization, respectively, to avoid the sensing crossover, eliminating the need for matrix calculation. Simultaneous detection of dual parameters can be implemented by monitoring the loss spectrum of core modes in two polarizations. Compared with the reported multi-function sensors, the designed PCF sensor provides higher sensitivities for both RI and temperature detection. A maximum wavelength sensitivity of −5 nm/°C is achieved in the temperature range of −30–40 °C. An excellent optimal wavelength sensitivity of 17,000 nm/RIU is accomplished in the RI range of 1.32–1.41. The best amplitude sensitivity of RI is up to 354.39 RIU−1. The resolution of RI and temperature sensing is 5.88 × 10−6 RIU and 0.02 °C, respectively. The highest value of the figure of merit (FOM) is 216.74 RIU−1. In addition, the flat polishing area of the gold layer reduces the manufacturing difficulty. The proposed sensor has the characteristics of high sensitivity, simple structure, good fabrication repeatability, and flexible operation. It has potential in medical diagnosis, chemical inspection, and many other fields.

12 May 2022 in Respiration
Verified
Journal Article
Closed access
PDF file
YWYimin Wang
Yimin Wang
YLYicong Li
Yicong Li
WCWenya Chen
Wenya Chen
CZChangzheng Zhang
Changzheng Zhang
LLLijuan Liang
Lijuan Liang
JZJinping Zheng
Jinping Zheng
Background: Due to the similar symptoms of upper airway obstruction to asthma, misdiagnosis is common. Spirometry is a cost-effective screening test for upper airway obstruction and its characteristic patterns involving fixed, variable intrathoracic and extrathoracic lesions. We aimed to develop a deep learning model to detect upper airway obstruction patterns and compared its performance with that of lung function clinicians. Methods: Spirometry records were reviewed to detect the possible condition of airway stenosis. Then they were confirmed by the gold standard (e.g., computed tomography, endoscopy, or clinic diagnosis of upper airway obstruction). Images and indices derived from flow-volume curves were used for training and testing the model. Clinicians determined cases using spirometry records from the test set. The deep learning model evaluated the same data. Results: Of 45,831 patients’ spirometry records, 564 subjects with curves suggesting upper airway obstruction, after verified by the gold standard, 351 patients were confirmed. These cases and another 200 cases without airway stenosis were used as the training and testing sets. 432 clinicians evaluated 20 cases of each of the three patterns and 20 no airway stenosis cases (n = 80). They assigned an accuracy of 41.2% (±15.4) (interquartile range: 27.5–52.5%), with poor agreements (κ = 0.12). For the same cases, the model generated a correct detection of 81.3% (p < 0.0001). Conclusions: Deep learning could detect upper airway obstruction patterns from other classic patterns of ventilatory defects with high accuracy, whereas clinicians presented marked errors and variabilities. The model may serve as a support tool to enhance clinicians’ correct diagnosis of upper airway obstruction using spirometry.

4 March 2024 in Applied Optics
Verified
Journal Article
Closed access
SGShijing Guo
Shijing Guo
CLChao Li
Chao Li
DWDong Wang
Dong Wang
WCWenya Chen
Wenya Chen
Song GaoSong Gao
Song Gao
JXJiaran Xiong
Jiaran Xiong
In this paper, a dual-band terahertz metamaterial sensor based on aluminum and silicon is proposed and simulated. The aluminum surface, which is deposited on a silicon substrate, is made of a C-shaped frame resonator, a rectangular beam, and a cross. The device is insensitive to the change of incident angle in the range of 0°–30°, which shows the great transmission stability of the sensor. By examining the resonance frequency shift, it is shown that 98.3 and 237.5 GHz/RIU refractive index sensitivity can be obtained near 1.76 and 2.404 THz transmission dips of the proposed structure, respectively. The two dips can be used to sense analytes in different refractive index ranges, respectively. For Dip 1 at 1.76 THz, the range is 1.0–1.6. For Dip 2 at 2.404 THz, the range is 1.6–2.0. Different from traditional multi-band metamaterial sensors, two dips generated by the proposed device can measure continuous and non-multiplexed refractive index ranges, respectively. Because the resonance frequencies of matters are different, such a characteristic enables the device to measure different types of analyte using the appropriate resonant peak. A central-relief design is then proposed based on perturbation theory to further improve its sensing performance. The aluminum cross is covered by polyimide, which can interfere with the scattering field on the metal surface and affect the transmission results. For both transmission dips, the optimized structure realizes higher sensitivities of 111.7 GHz/RIU and 262.5 GHz/RIU, respectively. More significantly, the optimized structure also has the characteristic of a wide and non-multiplexed refractive index range. In addition, the effects of analyte thickness and polyimide layer thickness on sensor performance are also discussed. The proposed structure opens up new prospects in the design of multiple-band terahertz metamaterial sensors. It can also meet the sensing needs of biomedical, environmental monitoring, and industrial manufacturing.

12 November 2024 in Applied Optics
Verified
Journal Article
Closed access
WCWenya Chen
Wenya Chen
CLChao Li
Chao Li
DWDong Wang
Dong Wang
Song GaoSong Gao
Song Gao
GWGuozheng Wu
Guozheng Wu
JXJiaran Xiong
Jiaran Xiong
A multifunctional terahertz functional device based on vanadium dioxide (VO2) and graphene is proposed, which can realize ultra-wideband absorption and polarization conversion. When the VO2 is in the insulating state, the device can achieve the polarization conversion function to convert the incident wave into the corresponding cross-polarized wave. Polarization conversion ratios (PCRs) can exceed 90% in the 2.1–8 THz frequency range; in the 3–7.5 THz range, the PCR can be more than 95%. When VO2 is in the metallic state and the graphene Fermi energy is 0.9 eV, the device can realize a broadband absorption function. An absorption rate of more than 90% can be achieved over a wide frequency range of 3.3–7.7 THz. In addition, the polarization conversion device can maintain high performance in broadband polarization conversion at incident angles no greater than 40°. The absorber device also exhibits insensitivity to both incident and polarization angles. These advantages which make the proposed multifunctional terahertz functional device have a wide range of applications in the fields of terahertz imaging, sensing, communication, and so on.