OBJECTIVE: To investigate the value of contrast-enhanced ultrasound (CEUS) for the diagnosis of cervical tuberculous lymphadenitis (CTL). METHODS: The cohort study included 203 consecutive patients diagnosed with cervical lymph node. Before pathological or laboratory confirmation, all patients underwent CEUS examination, and the imaging findings were analyzed afterward. The diagnostic efficiency of the CEUS imaging findings of CTL was evaluated. RESULTS: Nighty-seven patients of the 203 (47.8%) were pathologically or laboratory confirmed with a CTL diagnosis while the remainder (52.2%) were diagnosed with non-tuberculous lymphadenitis. Regarding the imaging findings of CEUS, it was more common in CTL patients to find a pattern of heterogeneous enhancement inside the lymph nodes relative to non-tuberculous patients [81.44% (79/97) vs 15.09% (16/106), P < 0.01]. The sensitivity of the feature in diagnosis for CTL was 81.44% and the specificity was 84.91%, resepectively. Furthermore, a pattern of peripheral rim-like enhancement had been notable in CTL patients compared with non-tuberculous patients [86.60% (84/97) vs 12.26% (13/106), P < 0.01], associating with a diagnostic sensitivity of 86.60% and a specificity of 87.74%. When it came to the combination of both imaging findings mentioned above, the features were more prominent in CTL patients than compared with non-tuberculous patients [74.23% (72/97) vs 5.66% (6/106), P < 0.01], with a diagnostic sensitivity of 74.23% and a high specificity of 94.34%. Regarding area under curve (AUC) for the ROC analysis, the feature of internal heterogeneous enhancement, peripheral rim-like enhancement, and both features were 0.832, 0.872, and 0.843. CONCLUSIONS: CEUS patterns of heterogeneous enhancement and peripheral rim-like enhancement of lymph nodes are helpful characteristics for the diagnosis of CTL.
Aim: To investigate the multimodal ultrasound(MMUS) features of cervical lymphadenopathy and to assess its value in the differential diagnosis of benign and malignant cervical lymph nodes.Methods: A retrospective analysis of 169 patients with cervical lymph node enlargement who attended Hangzhou Red Cross Hospital from March 2020 to October 2022. All patients underwent conventional ultrasound (CUS), contrast-enhanced ultrasound (CEUS), and real-time elastography (RTE), and were divided into training set and validation set. Univariate analysis was applied to screen out statistically significant parameters, and CUS model and MMUS model were constructed by multifactorial logistic regression analysis. The receiver operator characteristic (ROC) curve was established, and the area under the curve (AUC) was used to compare CUS model with MMUS model to assess the value of MMUS.Results: Of the cervical 169 lymph nodes in 169 patients included in the study. The 169 enrolled patients were divided into a training set (132 patients) and a validation set (37 patients). In the training set, univariate analysis showed statistically significant differences in long diameter/short diameter(L/S), border, margin, hilus, dermal medulla boundary, blood flow type, enhancement mode, enhancement type, and RTE score (all p< 0.05). Multifactor logistic analysis showed that L/S, blood flow type, enhancement mode and enhancement type were correlates of malignant lymph nodes (all p< 0.05). The comparison of AUC demonstrated that the discriminative ability of the MMUS model was superior to using the CUS model, both in the training set(p = 0.004) and validation set (p<0.001).Conclusion: In this study, MMUS shows higher diagnostic efficiency than CUS. Ultrasound features such as L/S, blood flow type, mode of enhancement, type of enhancement are helpful in distinguishing benign and malignant lymphadenopathy. The addition of CEUS can greatly improve the sensitivity and specificity of ultrasonic diagnosis of malignant cervical lymph nodes. RTE score is of limited value in the diagnosis of malignant cervical lymph nodes.
Background: Currently, there is no evidence-based medical evidence for the diagnosis of lymph node metastasis (LNM) of thyroid cancer (TC) by ultrasound combined with computed tomography (US + CT), and the results of various studies on its diagnostic efficacy are inconsistent. Therefore, the diagnosis of cervical LNM by US + CT is controversial at present. The aims of the present systematic review and meta-analysis were to evaluate the diagnostic performance of US + CT in parallel for diagnosing cervical LNM in patients with TC. Methods: We searched PubMed, EMBASE, Cochrane Library, Web of Science, and Wanfang Medical Network (Core journals only) for studies prior to May 2022 on the performance of US and CT in parallel for diagnosing cervical lymph nodes. The studies were screened according to inclusion and exclusion requirements, and the methodologic quality of the included studies was independently assessed by 2 reviewers using tailored questionnaires and criteria provided by Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). We calculated the sensitivity, specificity, and diagnostic odds ratio (DOR) of cervical LNM for the central region, lateral neck, and whole neck. Meta-regression was performed to determine which parameters caused high diagnostic heterogeneity. Results: We included 11 studies of 6,261 patients with TC and 8,394 non-TC patients were included in the study. Most of the risk assessments included in the study were low risk, with no high-risk items. For the parallel test of US + CT, pooled sensitivity and specificity in the central region and lateral neck were 0.73 [95% confidence interval (CI): 0.56–0.85] and 0.80 (95% CI: 0.72–0.85), respectively. The calculated positive likelihood ratio was 3.6 (95% CI: 2.9–4.4), negative likelihood ratio was 0.34 (95% CI: 0.20–0.56), and DOR was 11 (95% CI: 6–18). The area under the curve was 0.83. For US + CT, the pooled sensitivity and specificity in the central region and lateral neck were 0.73 (95% CI: 0.56–0.85) and 0.80 (95% CI: 0.72–0.85), respectively. Discussion: The diagnostic efficiency of CT for lateral cervical LNM is greater than for central cervical LNM. CT has high sensitivity and accuracy for the diagnosis of central cervical LNMs. US + CT is important for the preoperative examination of cervical LNMs in TC.
Interindividual variability in metabolic responses to diets complicates the relationship between nutrition and metabolic health, which highlights the existence of metabolic heterogeneity across populations. This variability challenges the conventional “one‐size‐fits‐all” approach to dietary recommendations and underscores the need for precision nutrition. In the current era, characterized by breakthroughs in sophisticated data collection technologies, the explosion of big data, and progress in artificial intelligence, the implementation of precision nutrition is becoming increasingly feasible. This review aims to summarize potential sources of metabolic heterogeneity from the angle of the host genome, gut microbiome, and brain connectome to explore the implications of their interactions with diet. Furthermore, we discuss the application of artificial intelligence in leveraging multimodal data for predicting individualized dietary responses. Aggregating data on host genetics, gut microbes, and brain activity profiling offers profound insights into the personalized response to diets. We also highlight the development of individual‐specific predictive models that combine n‐of‐1 study designs with advanced wearable technologies and machine learning algorithms, thereby placing the individual at the center of nutritional decision‐making. Finally, this review summarizes current challenges in the field and outlines potential directions for advancing precision nutrition.
Objectives: This study aimed to investigate the contrast-enhanced ultrasound (CEUS) appearances of prostate tuberculosis (PTB) and its correlation with histopathology. Methods: Clinical, transrectal ultrasonography (TRUS) and CEUS data of 12 PTB patients confirmed by pathology were retrospectively analyzed, and compared to the pathological findings to identify the pathological structures corresponding to different image enhancement areas. Results: No specific characteristics could be found for the clinical appearances. Enlarged gland, hypoechoic lesions and calcification due to PTB could be found by TRUS, which were also non-specific. CEUS showed hypo- or non-enhanced lesions with varying size, which were related to different pathological stages of PTB. The incidence rate of non-enhanced lesions was 83.3%. The detection rate of suspected lesion by CEUS was significantly higher than that by TRUS (χ2 = 8.000, p = 0.005). Histopathology showed that the hypoenhanced area consisted of tuberculous granulomas, caseous necrosis and incomplete destruction of the glands, while the non-enhanced area consisted of caseous or liquified necrosis. Conclusion: CEUS could improve the detection rate of PTB lesions, and the diversity of its manifestations was related to different pathological structures. An enlarged, soft gland with non-enhanced on CEUS may provide valuable information for the diagnosis of PTB, but it is not a substitute for biopsy due to the diversity of CEUS findings. Advances in knowledge: When the lesions of prostate gland are unclear in TRUS examination, CEUS is an ideal option for the detection of lesions, which is conducive to targeted guidance of biopsy areas.