By comparison of dynamic and pseudo-dynamic tests, it is shown that conventional construction materials exhibit pure hysteretic damping and consequently, when quasistatic restoring forces are measured directly, the addition of viscous damping in the equation of motion must be avoided unless it is intended to reflect missing physical elements. Equally important in pseudo-dynamic testing is the fact that the apparent damping can be easily distorted by the inevitable control errors. The identification of a spatial model from the results of the tests allows obtaining a reliable estimation of the damping distortion for each vibration mode.
Capacity curves obtained from nonlinear static analyses are widely used to perform seismic assessments of structures as an alternative to dynamic analysis. This paper presents a novel ‘en masse’ method to assess the seismic vulnerability of urban areas swiftly and with the accuracy of mechanical methods. At the core of this methodology is the calculation of the capacity curves of low-rise reinforced concrete buildings using neural networks, where no modeling of the building is required. The curves are predicted with minimal error, needing only basic geometric and material parameters of the structures to be specified. As a first implementation, a typology of prismatic buildings is defined and a training set of more than 7000 structures generated. The capacity curves are calculated through push-over analysis using SAP2000. The results feature the prediction of 100-point curves in a single run of the network while maintaining a very low mean absolute error. This paper proposes a method that improves current seismic assessment tools by providing a fast and accurate calculation of the vulnerability of large sets of buildings in urban environments.
This work summarises the strategy adopted in the European research project PERSISTAH. It aims to increase the resilience of the population, focusing on the existing primary schools in the Algarve (Portugal) and Huelva (Spain) regions. Software was developed to assess the seismic safety of these schools, considering different earthquake scenarios. Seismic retrofitting measures were studied and numerically tested. Some of them were also implemented in the retrofitting activities of two case study schools (one in each country). It was found that the adopted ground motion prediction equations (GMPEs) considerably affect the results obtained with the software, especially for offshore earthquake scenarios. Furthermore, the results show that the masonry buildings would be the most damaged school typologies for all the scenarios considered. Additionally, a set of guidelines was created to support the school community and the technicians related to the construction industry. The goal of these documents is to increase the seismic resilience of the population. Different activities were carried out to train schoolteachers in seismic safety based on the guidelines produced, obtaining positive feedback from them.
7 November 2020 in Bulletin of Earthquake Engineering
Previous research has indicated that many European buildings are vulnerable to moderate-magnitude earthquakes. For example, during the L´Aquila (Italia, Mw 6.3, 2009) and Lorca (Spain, Mw 5.9, 2011) earthquakes, many old buildings were severely damaged and some of them collapsed. In specific, significant damage has been found in several school buildings after past earthquakes in Europe. This is due to the fact that many of them were constructed prior to the current seismic codes, thus considering only gravitational loads and with no seismic design whatsoever. Primary schools are even more vulnerable than other typologies because of their low adult/child ratio. The seismic activity of the Iberian Peninsula is low-moderate. However, the Algarve and Huelva regions, which are situated in the south-west, are influenced by large faults which have caused major earthquakes of long-return periods. The European project PERSISTAH (Projetos de Escolas Resilientes aos SISmos no Território do Algarve e de Huelva, in Portuguese) aims to cooperatively evaluate the seismic vulnerability of primary schools in the Algarve (Portugal) and Huelva (Spain) regions. The present work is framed under this project. The objective of this paper is to determine the most effective retrofitting scheme for a typical primary school building in this area, considering structural, architectural and constructive parameters. The scheme could be applied to several buildings of the same typology, decreasing costs and time. An existing reinforced concrete frame building has been selected for the study. This is one of the most commonly used typologies for primary schools in this area. A nonlinear static analysis has been carried out in order to study its seismic behaviour. The performance point of the building has been obtained through the capacity-demand spectrum method. The preliminary results have confirmed the poor seismic behaviour of this building. Specifically, soft-story behaviour has been identified in the ground floor and short columns have been observed in the upper floors. Therefore, specific seismic retrofitting solutions have been proposed and evaluated in order to identify the one that is the most efficient. The combination of reinforcements has been done considering the structural and architectural impact and constructive parameters. The calculations have shown that steel X-bracings are the best solution for preventing the formation of a soft-storey in the ground floor. Unfortunately, this scheme increases the deformation in the upper floor columns. The best solution for the upper floors’ short columns has been the use of steel jackets. The results have also shown that this combination produces an important reduction of the expected general damage level. The resulting retrofitting scheme can be extrapolated to other buildings with a similar typology.