Some soft magnetic metallic glasses are considered for use in magnetic cores of accelerator radio frequency cavities. Due to losses of the circulating ion beam, they may be exposed to irradiation by different ions at different energies. This paper presents data and review results of irradiation experiments concerning the influence of high-energy heavy ions on magnetic susceptibility of VITROPERM®-type metallic glasses. Samples of the VITROPERM® magnetic ribbons were irradiated by Au, Xe and U ions at 11.1 MeV/A (per nucleon) and 5.9 MeV/A, respectively. Irradiation fluences from 1 × 1011 up to 1 × 1013 ions/cm2 were applied. In case of the Au and U ions, the total fluence was accumulated in one beamtime, whereas two separate beamtimes were used to accumulate the final fluence in case of the Xe ions. Relative change in the samples’ magnetic susceptibility after and before irradiation was evaluated as a function of the irradiation fluence. The irradiation experiments were performed with the UNILAC accelerator at GSI Helmholtzzentrum für Schwerionenforschung GmbH. They were simulated in SRIM2010 in order to obtain ionization densities (electronic stopping, dE/dx) and dpa (displacements per atom) caused by the ion beams in the sample material. This paper focuses mainly on the results collected in experiments with the Xe ions and compares them with data obtained in earlier experiments using Au and U ions. Radiation hardness of VITROPERM® is compared with radiation hardness of VITROVAC® that was studied in previous experiments. The VITROPERM® samples showed less drop in magnetic susceptibility in comparison with the VITROVAC® ones, and this drop occurred at higher fluences. This indicates higher radiation hardness of VITROPERM® compared with VITROVAC®. In addition, heavier ions cause bigger change in magnetic susceptibility than the lighter ones. The effect can be roughly scaled with electronic stopping, which suggests that the main mechanism of radiation damage is associated with swift electrons generated in the material via ionization by primary heavy ions.
26 February 2024 in Physical Review Accelerators and Beams
This paper provides an overview of the worldwide first commissioning of a gantry beamline with a rotator at the MedAustron synchrotron-based proton/ion cancer therapy facility in Wiener Neustadt, Austria. The gantry beamline consists of the high energy beam transfer (HEBT) line and the gantry beam transport system. It transports the beam from the synchrotron to the gantry-room isocenter. The HEBT transports the beam from the synchrotron to the gantry entrance, which is the coupling point between the HEBT and the gantry. The rotator is one of the HEBT modules, thus it is an integral part of the gantry beamline. The MedAustron rotator is the worldwide first rotator system used to match slowly extracted asymmetric beams from the synchrotron to the rotating gantry. In this paper, main attention is paid to ion-optical and beam-alignment aspects of the beamline commissioning. A novel orbit-correction and beam-alignment technique has been developed specifically for the beamline with the rotator. While the theoretical concept of the rotator has existed for almost two decades, the MedAustron rotator is the first hardware implementation of this concept all over the world. The presented overview of the beamline commissioning includes a description of the principal technical solutions and main results of the first beam-transport measurements. Since the measured beam size and beam position agree well with theoretical predictions, one can conclude that the proof-of-concept of the rotator-matching has been successfully accomplished. Published by the American Physical Society 2024
1 August 2009 in Radiation Effects and Defects in Solids
The paper presents some of the S3M (SRIM Supporting Software Modules) routines relevant for running SRIM simulations with a realistic input beam model. These routines make a bridge between the beam-envelope sigma-matrix formalism and an ensemble of individual particles. The sigma-matrix formalism is used in beam-transport codes calculating the beam parameters at the exit of the beam-preparation line. These beam parameters are converted into an ensemble of individual particles suitable for Monte Carlo simulations of particle interactions with matter inside a target by the SRIM code. An opposite routine converting the ensemble of individual particles back to the beam parameters is available as well. This routine can be used to calculate the beam transport with scattering. Examples of typical applications are given to compare standard SRIM simulations using a zero-emittance input beam with the improved simulations using the realistic input beam.
26 July 2024 in Physical Review Accelerators and Beams
Rotating gantries are commonly used in ion-therapy facilities to assist and support optimizing the dose distribution delivered to the patient. They are installed at the end of the beamlines and rotated mechanically in the treatment room. In synchrotron-based facilities, the gantries must be able to transport slowly extracted beams with essentially different emittance patterns in the two transverse planes. Such beams will be referred to as the asymmetric beams. A special device called rotator has been proposed as a possible solution. The worldwide first beamline with the rotator has been recently commissioned. The original rotator concept uses an “external” rotator that is a part (a module) of the beamline the gantry is connected to. In this paper, a novel gantry ion-optical concept integrating the rotator optics into the gantry optics is introduced. The first-order gantry transfer matrix satisfies the so-called sigma-matching ion-optical constraints, and—at the same time—it possesses the format of a rotator transfer matrix. The rotator-matching and the sigma-matching principles are combined in the gantry transfer matrix, which means that the sigma-matching gantry acts simultaneously as a rotator without the need for an extra rotator device. In addition, scattering in the gantry nozzle is used to balance the asymmetric beam emittances in the two transverse planes without an additional scattering foil. In this way, the presented ion-optical concept combines all three known matching techniques—the sigma matching, the rotator matching, and the scattering-foil matching—within the gantry beam transport system. Such a beam transport system provides the best matching result and full angular independence of the beam parameters at the gantry isocenter. It also makes it possible to optimize the beam parameters not only at the gantry isocenter but also at the beam monitors located in the gantry nozzle without increasing the number of gantry quadrupoles. There are two possible versions of such gantry optics: the point-to-point and the parallel-to-point optics. They both are presented in this paper. Theoretical calculations are supported by beam transport simulations performed with the in code. Feasibility of the newly proposed ion-optical concept is demonstrated on the MedAustron proton gantry. However, it can be applied to any rotating gantry at any ion-therapy facility. The presented design is the first rotatorlike gantry ion-optical concept worldwide. Published by the American Physical Society 2024