A miniaturised sensor displayed efficient analytical performance with differences in kinetics from the macroelectrodes, attributed to the structural differences in probe accessibility.
The extrinsic and intrinsic factors having a crucial impact on efficient and selective electrochemical CO2 reduction have been reviewed and discussed in this review.
23 October 2014 in The Journal of Chemical Physics
We investigated the tribological interaction between polytetrafluoroethylene (PTFE) and silicon oxide surfaces. A simple rig was designed to bring about a friction between the surfaces via sliding a piece of PTFE on a thermally oxidized silicon wafer specimen. A very mild inclination (∼0.5°) along the sliding motion was also employed in order to monitor the tribological interaction in a gradual manner as a function of increasing contact force. Additionally, some patterns were sketched on the silicon oxide surface using the PTFE tip to investigate changes produced in the hydrophobicity of the surface, where the approximate water contact angle was 45° before the transfer. The nature of the transferred materials was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). XPS results revealed that PTFE was faithfully transferred onto the silicon oxide surface upon even at the slightest contact and SEM images demonstrated that stable morphological changes could be imparted onto the surface. The minimum apparent contact pressure to realize the PTFE transfer is estimated as 5 kPa, much lower than reported previously. Stability of the patterns imparted towards many chemical washing processes lead us to postulate that the interaction is most likely to be chemical. Contact angle measurements, which were carried out to characterize and monitor the hydrophobicity of the silicon oxide surface, showed that upon PTFE transfer the hydrophobicity of the SiO2 surface could be significantly enhanced, which might also depend upon the pattern sketched onto the surface. Contact angle values above 100° were obtained.
Implantable electrochemical sensors that enable the real-time detection of significant biomarkers offer huge potential for the enhancement and personalisation of therapies; however, biofouling is a key challenge encountered by any implantable system. This is particularly an issue immediately after implantation, when the foreign body response and associated biofouling processes are at their most active in passivating a foreign object. Here, we present the development of a sensor protection and activation strategy against biofouling, based on coatings consisting of a pH-triggered, dissolvable polymer, that covered a functionalised electrode surface. We demonstrate that reproducible delayed sensor activation can be achieved, and that the length of this delay can be controlled by the optimisation of coating thickness, homogeneity and density through tuning of the coating method and temperature. Comparative evaluation of the polymer-coated and uncoated probe-modified electrodes in biological media revealed significant improvements in their anti-biofouling characteristics, demonstrating that this offers a promising approach to the design of enhanced sensing devices.
12 April 2025 in Korean Journal of Chemical Engineering
Transistor-based platforms offer several advantages for chemical and biological sensing application over conventional electrochemical systems, including enhanced sensitivity, portability, cost-effectiveness, and biocompatibility. However, these devices often require functionalization with specific recognition units, introducing challenges related to the chemical stability of conjugated units, their conformation, and Debye length effects. Lipid-based biomembranes, particularly supported lipid bilayers (SLBs), can mimic the native architecture of cell membranes, acting as biointerfaces that facilitate signal transduction between extra- and intracellular environments. They also provide selective permeability to ions, specificity to biochemicals, as well as ease of integration with diverse materials. Over the past two decades, researchers have focused on integrating biomembranes with transistor platforms to advance bioelectronic sensing technologies and enhance the understanding and monitoring of biological processes. This review explores integrating various lipid-based biomembrane types with transistor-based devices. We review fundamental techniques for producing and characterizing biomembranes, the advantages and limitations of different transistor types, and their working principles in biomembrane-based systems. Additionally, we highlight recent developments in biomembrane-integrated sensing platforms, including their incorporation into transistor architectures, further functionalization with biorecognition units, and applications in detecting analytes.