Eisuke Hanada

Prof. Eisuke Hanada

Faculty of Science and Engineering, Saga University, Saga, Japan
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NNNishat Tasnim Newaz
Nishat Tasnim Newaz
EHEisuke Hanada
Eisuke Hanada
Fall Detection Systems (FDS) are automated systems designed to detect falls experienced by older adults or individuals. Early or real-time detection of falls may reduce the risk of major problems. This literature review explores the current state of research on FDS and its applications. The review shows various types and strategies of fall detection methods. Each type of fall detection is discussed with its pros and cons. Datasets of fall detection systems are also discussed. Security and privacy issues related to fall detection systems are also considered in the discussion. The review also examines the challenges of fall detection methods. Sensors, algorithms, and validation methods related to fall detection are also talked over. This work found that fall detection research has gradually increased and become popular in the last four decades. The effectiveness and popularity of all strategies are also discussed. The literature review underscores the promising potential of FDS and highlights areas for further research and development.

1 January 2000 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
EHEisuke Hanada
Eisuke Hanada
YAY. Antoku
Y. Antoku
STS. Tani
S. Tani
MKM. Kimura
M. Kimura
AHA. Hasegawa
A. Hasegawa
YNY. Nose
Y. Nose
There have been a number of reports of electromagnetic interference (EMI) on electronic medical equipment caused by mobile telecommunication systems. In Japan, the use of the personal handy-phone system (PHS) has greatly expanded within urban areas, PHS handsets transmit EM signals at a frequency of 1.9 GHz and have a peak radiated power of 80 mW. This power level is lower than that of other mobile telecommunication systems. Two studies were carried out. One was to determine whether or not PHS interferes with electronic medical equipment in hospitals. We observed no EMI on electronic medical equipment when the PHS handset was in either the speaking mode or on standby. The second study was to observe EMI from 1.9-GHz signals at several radiation power levels. Although EMI was not observed at the radiated peak power of the PHS handset, EMI on some of the tested equipment was observed when the radiated power was ten or more times higher than that of the PHS handset.

1 January 2010
Verified
Book Chapter
Open access
PDF file
EHEisuke Hanada
Eisuke Hanada
STShusaku Tsumoto
Shusaku Tsumoto
SKShotai Kobayashi
Shotai Kobayashi
Fully computerized hospital information systems (HIS) are spreading in Japanese hospitals. Most HIS consist of server computers, terminals, a database, and a LAN. The introduction of HIS has enabled quick communication between doctors and staff and the immediate dissemination of patient information. Installation of a wireless data communication system compatible with a HIS has been reported to improve efficiency. However, also necessary is a voice communication system that can transmit instructions quickly in emergencies, such as a sudden change in the health status of an inpatient. In the Japanese medical community, "An environment in which access and the sharing of information are possible anywhere and at all times" is called a "ubiquitous environment." In order to attain such an environment, a telecom infrastructure with a mobile communications network is very important to voice and data communication. Here, we show the "ubiquitous environment" realized in Shimane University Hospital and how it has improved efficiency.

20 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QHQisthi Alhazmi Hidayaturrohman
Qisthi Alhazmi Hidayaturrohman
EHEisuke Hanada
Eisuke Hanada
This study presents a comparative analysis of hyper-parameter optimization methods used in developing predictive models for patients at risk of heart failure readmission and mortality. We evaluated three optimization approaches—Grid Search (GS), Random Search (RS), and Bayesian Search (BS)—across three machine learning algorithms—Support Vector Machine (SVM), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost). The models were built using real patient data from the Zigong Fourth People’s Hospital, which included 167 features from 2008 patients. The mean, MICE, kNN, and RF imputation techniques were implemented to handle missing values. Our initial results showed that SVM models outperformed the others, achieving an accuracy of up to 0.6294, sensitivity above 0.61, and an AUC score exceeding 0.66. However, after 10-fold cross-validation, the RF models demonstrated superior robustness, with an average AUC improvement of 0.03815, whereas the SVM models showed potential for overfitting, with a slight decline (−0.0074). The XGBoost models exhibited moderate improvement (+0.01683) post-validation. Bayesian Search had the best computational efficiency, consistently requiring less processing time than the Grid and Random Search methods. This study reveals that while model selection is crucial, an appropriate optimization method and imputation technique significantly impact model performance. These findings provide valuable insights for developing robust predictive models for healthcare applications, particularly for heart failure risk assessment.

1 November 2024 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
QHQisthi Alhazmi Hidayaturrohman
Qisthi Alhazmi Hidayaturrohman
EHEisuke Hanada
Eisuke Hanada
Background: Heart failure poses a significant global health challenge, with high rates of readmission and mortality. Accurate models to predict these outcomes are essential for effective patient management. This study investigates the impact of data pre-processing techniques on XGBoost model performance in predicting all-cause readmission and mortality among heart failure patients. Methods: A dataset of 168 features from 2008 heart failure patients was used. Pre-processing included handling missing values, categorical encoding, and standardization. Four imputation techniques were compared: Mean, Multivariate Imputation by Chained Equations (MICEs), k-nearest Neighbors (kNNs), and Random Forest (RF). XGBoost models were evaluated using accuracy, recall, F1-score, and Area Under the Curve (AUC). Robustness was assessed through 10-fold cross-validation. Results: The XGBoost model with kNN imputation, one-hot encoding, and standardization outperformed others, with an accuracy of 0.614, recall of 0.551, and F1-score of 0.476. The MICE-based model achieved the highest AUC (0.647) and mean AUC (0.65 ± 0.04) in cross-validation. All pre-processed models outperformed the default XGBoost model (AUC: 0.60). Conclusions: Data pre-processing, especially MICE with one-hot encoding and standardization, improves XGBoost performance in heart failure prediction. However, moderate AUC scores suggest further steps are needed to enhance predictive accuracy.

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NNNishat Tasnim Newaz
Nishat Tasnim Newaz
EHEisuke Hanada
Eisuke Hanada
This research uses a low-resolution infrared array sensor to address real-time human activity recognition while prioritizing the preservation of privacy. The proposed system captures thermal pixels that are represented as a human silhouette. With camera and image processing, it is easy to detect human activity, but that reduces privacy. This work proposes a novel human activity recognition system that uses interpolation and mathematical measures that are unobtrusive and do not involve machine learning. The proposed method directly and efficiently recognizes multiple human states in a real-time environment. This work also demonstrates the accuracy of the outcomes for various scenarios using traditional ML approaches. This low-resolution IR array sensor is effective and would be useful for activity recognition in homes and healthcare centers.