In this paper, we propose a distributionally robust chance constrained (DRCC) optimization problem for the operation of an active distribution network (ADN). The ADN’s operator uses the proposed problem to centrally optimize the dispatch plan of his resources, namely photovoltaic (PV) and battery energy storage (BES) systems, and to participate in wholesale real/reactive power and flexibility markets. We model the uncertainties in the problem by knowing a set of probability distributions, i.e., an ambiguity set. The uncertainties include production capability of PV systems, end-users’ consumption, requested flexibility by the external network’s operator, and voltage magnitude at the point of common coupling (PCC). The resulting formulation is a DRCC optimization problem for which a solution methodology based on freely available solvers is presented. We evaluate the performance of proposed solution in the numerical results section by comparing it with two benchmark models based on stochastic and chance constrained (CC) optimization.
A distorted grid voltage or nonlinear behavior in the current control loop can cause low frequency current harmonics in a grid-connected voltage source inverter (VSI). Many efforts have been made to mitigate such phenomena, including hardware and/or control structure improvements. A well-known suitable strategy to reduce current harmonics in a selective manner is to apply a Proportional Multi-Resonant (PMR) current controller. Inverter-grid stability is another common issue when dealing with grid-connected VSI. Stability is influenced by the inverter impedance, which depends on the controller parameters. This paper presents a simplified tuning strategy for the PMR controller, taking into consideration the inverter-grid stability issue. The obtained controller was implemented and tested in a 10 kW three-phase inverter with a passively damped LCL filter. A significant reduction of current harmonics emission from the inverter up to 650 Hz was achieved without any hardware modification. The limits of PMR controllers to mitigate current harmonics were studied, and the influence of the grid impedance was verified.
The increasing interest in Hybrid Electric Vehicles led to the study of new powertrain structures. In particular, it was demonstrated in the technical literature how series architecture can be more efficient, compared to parallel one, if supercapacitors are used as storage system. Since supercapacitors are characterized by high efficiency and high power density, but have low specific energy, storage sizing is a critical point with this technology. In this study, a detailed analysis on the effect of supercapacitor storage sizing on series architecture was carried out. In particular, in series architecture, supercapacitor storage sizing influences both engine number of starts and the energy that can be stored during regenerative braking. The first aspect affects the comfort, whereas the second aspect directly influences powertrain efficiency. Vehicle model and Energy Management System were studied and simulations were carried out for different storage energy, in order to define the optimal sizing.
7 April 2021 in IEEE Transactions on Industrial Electronics
In this article, a novel approach to determine the model of an independently controlled neutral leg is proposed. Based on this model, a cascaded control method is developed to provide a steady neutral point connection for a three-phase four-wire inverter and to balance the two dc capacitors voltages of a split dc-bus. Validation of the model is realised by simulations and the control has been tested by experiments. Results have shown good performance even with a high level of neutral current, which demonstrate the ability of the system to work within an unbalanced load or grid.