1 September 2006 in Journal of Architectural Engineering
When blasts occur in urban areas, many injuries and sometimes deaths result when glass shards fly from windows fractured by airblast pressure. The use of blast-resistant glazing can mitigate the number and severity of glass-related injuries if blasts occur. In this paper, the writers present two methods to facilitate blast-resistant glazing design. One of these methods is primarily restricted to government facilities while the other exists in a consensus document for public use. Both of these methods rely on laminated glass as the blast-resistant glazing material. Both methods address all facets of blast-resistant glazing design, including attachment of the glazing to the framing members and an estimate of the forces necessary for designing framing members and connections.
1 March 2018 in Journal of Architectural Engineering
The method for determining load resistance of insulating glass in ASTM standards uses a load-share factor equation based only on glass-lite thicknesses to estimate the load carried by each lite. This paper presents an experimental investigation of load sharing of double- and triple-glazed insulating glass units. The major factors varied in the investigation include unit rectangular dimensions, glass-lite thicknesses, and initial airspace volumes. Pressure versus deflection curves are presented for select insulating glass unit configurations. A second testing procedure explores the measured change in pressure within the sealed airspaces while simultaneously measuring applied pressure and associated deflections. Changes in pressures in the sealed airspaces are directly compared to the ASTM standard load-share factors. Figures in this paper show the load-sharing trends of various similarly loaded insulating glass units, and the results presented in this paper suggest many of the neglected factors significantly influence load sharing in insulating glass units.
1 September 2016 in Journal of Architectural Engineering
The authors performed an experimental study with weathered fully tempered monolithic glass loaded to failure under controlled conditions. The 14 specimens in the study originated from the northeastern United States. The specimens were loaded with monotonically increasing pressure until fracture occurred in accordance with the ASTM E997 test method. The recorded failure load time histories were converted to equivalent 3-s failure loads using a modified load-transformation-integration method that incorporates residual compressive surface stress. Variations of the residual compressive surface stress measurements are presented for each specimen, and the effect that the variations in residual compressive surface stress have on the equivalent 3-s failure load calculations are also explored. Equivalent 3-s failure loads are shown to be proportional to the measured residual compressive surface stress. The equivalent 3-s failure load is compared to the load resistance calculated using ASTM E1300, and the m...
1 April 2021 in Journal of Wind Engineering and Industrial Aerodynamics
1 March 2012 in Journal of Architectural Engineering
ASTM E 1300-07 employs only two glass type factors to adjust the load resistance of annealed glass for heat treatment, one factor for heat-strengthened glass and one factor for tempered glass. The use of only two factors provides a simplistic approach that fails to utilize the full capacity of heat-treated glass. ASTM E 1300-07 differentiates heat-strengthened from fully tempered glass by the magnitude of the residual compressive surface stress resulting from the heat treating process. Furthermore, ranges of residual compressive surface stress are specified for both heat-strengthened and fully tempered glasses, suggesting the glass type factors should vary with the residual compressive surface stress. This article presents a rational method for determining the load resistance of heat-treated glass based on the residual compressive surface stress. A method incorporating previously accepted design principles with the addition of extensive data computation is advanced to calculate load resistance for heat-treated glass. With the new method including the use of 25 additional charts, designers can easily design heat-treated glass based on any value of residual compressive surface stress.
23 May 2016 in Glass Structures & Engineering