SELİM KAYA

Dr. SELİM KAYA

Department of Physics Engineering, Gümüşhane University, Gümüşhane, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2007 in Energy & Fuels
Verified
Journal Article
Closed access
UCUgur Cevik
Ugur Cevik
NDNevzat Damla
Nevzat Damla
BKBahadır Koz
Bahadır Koz
SKSELİM KAYA
SELİM KAYA

9 February 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SKSELİM KAYA
SELİM KAYA
NÇNecati Çeli̇k
Necati Çeli̇k
TBTuncay Bayram
Tuncay Bayram

1 September 2007 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
UCU. Cevik
U. Cevik
SKSELİM KAYA
SELİM KAYA
BEB. Ertugral
B. Ertugral
HBH. Baltas
H. Baltas
SKS.M. Karabıdak
S.M. Karabıdak

1 May 2008 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
BKB. Koz
B. Koz
UCU. Cevik
U. Cevik
TOT. Ozdemir
T. Ozdemir
CDCelal Duran
Celal Duran
SKSELİM KAYA
SELİM KAYA
NCN. Celik
N. Celik

19 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSELİM KAYA
SELİM KAYA
In the current study, the effects of silver (Ag) additive on the radiation shielding efficiency of BiPbSrCaCuO superconducting ceramics was calculated using the EGS4 code and discussed theoretically by comparison with XCOM data. The mass attenuation coefficients (µ/ρ) for BiPbSrCaCuO superconductor ceramics and their contents were investigated theoretically (WinXcom and EGS4) at gamma-ray energies ranging from 59.5 to 1332 keV. The theoretical values were computed in the energy range from 1 keV to 100 MeV using the WinXcom program. Then, using the mass attenuation coefficients, some shielding parameters were determined, such as the mean free path (MFP), the half value layer (HVL), the effective atomic number (Zeff), the radiation protection efficiency (RPE), the macroscopic fast neutron removal cross-sections (ΣR, cm−1) and the gamma-ray kerma coefficients (kγ). Theoretically, the results obtained with XCOM and EGS-4 were found to be in good agreement. The radiation shielding efficiency (RPE), neutron removal cross-section (ΣR, cm−1), maximum and semi-valent layer (HVL), and mean free path (MFP) values were found to be smaller for BiPbSrCaCuO superconducting ceramics as the silver (Ag) contribution was increased. Data from this study can guide further research and development of shielding materials for gamma-ray and neutron shielding.