Silvia Del Din

Dr. Silvia Del Din

Newcastle University, Newcastle upon Tyne, UK
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in The Lancet
Verified
Journal Article
Open access
AMAnat Mirelman
Anat Mirelman
LRLynn Rochester
Lynn Rochester
IMInbal Maidan
Inbal Maidan
Silvia Del DinSilvia Del Din
Silvia Del Din
Lisa AlcockLisa Alcock
Lisa Alcock
JHJeffrey M Hausdorff
Jeffrey M Hausdorff
Age-associated motor and cognitive deficits increase the risk of falls, a major cause of morbidity and mortality. Because of the significant ramifications of falls, many interventions have been proposed, but few have aimed to prevent falls via an integrated approach targeting both motor and cognitive function. We aimed to test the hypothesis that an intervention combining treadmill training with non-immersive virtual reality (VR) to target both cognitive aspects of safe ambulation and mobility would lead to fewer falls than would treadmill training alone. We carried out this randomised controlled trial at five clinical centres across five countries (Belgium, Israel, Italy, the Netherlands, and the UK). Adults aged 60-90 years with a high risk of falls based on a history of two or more falls in the 6 months before the study and with varied motor and cognitive deficits were randomly assigned by use of computer-based allocation to receive 6 weeks of either treadmill training plus VR or treadmill training alone. Randomisation was stratified by subgroups of patients (those with a history of idiopathic falls, those with mild cognitive impairment, and those with Parkinson's disease) and sex, with stratification per clinical site. Group allocation was done by a third party not involved in onsite study procedures. Both groups aimed to train three times per week for 6 weeks, with each session lasting about 45 min and structured training progression individualised to the participant's level of performance. The VR system consisted of a motion-capture camera and a computer-generated simulation projected on to a large screen, which was specifically designed to reduce fall risk in older adults by including real-life challenges such as obstacles, multiple pathways, and distracters that required continual adjustment of steps. The primary outcome was the incident rate of falls during the 6 months after the end of training, which was assessed in a modified intention-to-treat population. Safety was assessed in all patients who were assigned a treatment. This study is registered with ClinicalTrials.gov, NCT01732653. Between Jan 6, 2013, and April 3, 2015, 302 adults were randomly assigned to either the treadmill training plus VR group (n=154) or treadmill training alone group (n=148). Data from 282 (93%) participants were included in the prespecified, modified intention-to-treat analysis. Before training, the incident rate of falls was similar in both groups (10·7 [SD 35·6] falls per 6 months for treadmill training alone vs 11·9 [39·5] falls per 6 months for treadmill training plus VR). In the 6 months after training, the incident rate was significantly lower in the treadmill training plus VR group than it had been before training (6·00 [95% CI 4·36-8·25] falls per 6 months; p<0·0001 vs before training), whereas the incident rate did not decrease significantly in the treadmill training alone group (8·27 [5·55-12·31] falls per 6 months; p=0·49). 6 months after the end of training, the incident rate of falls was also significantly lower in the treadmill training plus VR group than in the treadmill training group (incident rate ratio 0·58, 95% CI 0·36-0·96; p=0·033). No serious training-related adverse events occurred. In a diverse group of older adults at high risk for falls, treadmill training plus VR led to reduced fall rates compared with treadmill training alone. European Commission.

25 July 2016 in Movement Disorders
Verified
Journal Article
Open access
PDF file
Silvia Del DinSilvia Del Din
Silvia Del Din
Alan GodfreyAlan Godfrey
Alan Godfrey
Claudia MazzàClaudia Mazzà
Claudia Mazzà
SLSue Lord
Sue Lord
LRLynn Rochester
Lynn Rochester
Wearable technology comprises miniaturized sensors (eg, accelerometers) worn on the body and/or paired with mobile devices (eg, smart phones) allowing continuous patient monitoring in unsupervised, habitual environments (termed free‐living). Wearable technologies are revolutionizing approaches to health care as a result of their utility, accessibility, and affordability. They are positioned to transform Parkinson's disease (PD) management through the provision of individualized, comprehensive, and representative data. This is particularly relevant in PD where symptoms are often triggered by task and free‐living environmental challenges that cannot be replicated with sufficient veracity elsewhere. This review concerns use of wearable technology in free‐living environments for people with PD. It outlines the potential advantages of wearable technologies and evidence for these to accurately detect and measure clinically relevant features including motor symptoms, falls risk, freezing of gait, gait, functional mobility, and physical activity. Technological limitations and challenges are highlighted, and advances concerning broader aspects are discussed. Recommendations to overcome key challenges are made. To date there is no fully validated system to monitor clinical features or activities in free‐living environments. Robust accuracy and validity metrics for some features have been reported, and wearable technology may be used in these cases with a degree of confidence. Utility and acceptability appears reasonable, although testing has largely been informal. Key recommendations include adopting a multidisciplinary approach for standardizing definitions, protocols, and outcomes. Robust validation of developed algorithms and sensor‐based metrics is required along with testing of utility. These advances are required before widespread clinical adoption of wearable technology can be realized. © 2016 International Parkinson and Movement Disorder Society

2 April 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
Silvia Del DinSilvia Del Din
Silvia Del Din
Alan GodfreyAlan Godfrey
Alan Godfrey
LRLynn Rochester
Lynn Rochester
Measurement of gait is becoming important as a tool to identify disease and disease progression, yet to date its application is limited largely to specialist centers. Wearable devices enables gait to be measured in naturalistic environments, however questions remain regarding validity. Previous research suggests that when compared with a laboratory reference, measurement accuracy is acceptable for mean but not variability or asymmetry gait characteristics. Some fundamental reasons for this have been presented, (e.g., synchronization, different sampling frequencies) but to date this has not been systematically examined. The aims of this study were to: 1) quantify a comprehensive range of gait characteristics measured using a single triaxial accelerometer-based monitor; 2) examine outcomes and monitor performance in measuring gait in older adults and those with Parkinson's disease (PD); and 3) carry out a detailed comparison with those derived from an instrumented walkway to account for any discrepancies. Fourteen gait characteristics were quantified in 30 people with incident PD and 30 healthy age-matched controls. Of the 14 gait characteristics compared, agreement between instruments was excellent for four (ICCs 0.913-0.983); moderate for four (ICCs 0.508-0.766); and poor for six characteristics (ICCs 0.637-0.370). Further analysis revealed that differences reflect an increased sensitivity of accelerometry to detect motion, rather than measurement error. This is most likely because accelerometry measures gait as a continuous activity rather than discrete footfall events, per instrumented tools. The increased sensitivity shown for these characteristics will be of particular interest to researchers keen to interpret “real-world” gait data. In conclusion, use of a body-worn monitor is recommended for the measurement of gait but is likely to yield more sensitive data for asymmetry and variability features.

12 May 2016 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Silvia Del DinSilvia Del Din
Silvia Del Din
Alan GodfreyAlan Godfrey
Alan Godfrey
BGBrook Galna
Brook Galna
SLSue Lord
Sue Lord
LRLynn Rochester
Lynn Rochester
Gait is emerging as a powerful diagnostic and prognostic tool, and as a surrogate marker of disease progression for Parkinson’s disease (PD). Accelerometer-based body worn monitors (BWMs) facilitate the measurement of gait in clinical environments. Moreover they have the potential to provide a more accurate reflection of gait in the home during habitual behaviours. Emerging research suggests that measurement of gait using BWMs is feasible but this has not been investigated in depth. The aims of this study were to explore (i) the impact of environment and (ii) ambulatory bout (AB) length on gait characteristics for discriminating between people with PD and age-matched controls. Fourteen clinically relevant gait characteristics organised in five domains (pace, variability, rhythm, asymmetry, postural control) were quantified using laboratory based and free-living data collected over 7 days using a BWM placed on the lower back in 47 PD participants and 50 controls. Free-living data showed that both groups walked with decreased pace and increased variability, rhythm and asymmetry compared to walking in the laboratory setting. Four of the 14 gait characteristics measured in free-living conditions were significantly different between controls and people with PD compared to two measured in the laboratory. Between group differences depended on bout length and were more apparent during longer ABs. ABs ≤ 10s did not discriminate between groups. Medium to long ABs highlighted between-group significant differences for pace, rhythm and asymmetry. Longer ABs should therefore be taken into account when evaluating gait characteristics in free-living conditions. This study provides encouraging results to support the use of a single BWM for free-living gait evaluation in people with PD with potential for research and clinical application.

3 May 2019 in European Review of Aging and Physical Activity
Verified
Journal Article
Open access
PDF file
IHInbar Hillel
Inbar Hillel
EGEran Gazit
Eran Gazit
ANAlice Nieuwboer
Alice Nieuwboer
LALaura Avanzino
Laura Avanzino
LRLynn Rochester
Lynn Rochester
Jeffrey HausdorffJeffrey Hausdorff
Jeffrey Hausdorff
The traditional evaluation of gait in the laboratory during structured testing has provided important insights, but is limited by its “snapshot” character and observation in an unnatural environment. Wearables enable monitoring of gait in real-world environments over a week. Initial findings show that in-lab and real-world measures differ. As a step towards better understanding these gaps, we directly compared in-lab usual-walking (UW) and dual-task walking (DTW) to daily-living measures of gait. In-lab gait features (e.g., gait speed, step regularity, and stride regularity) derived from UW and DTW were compared to the same gait features during daily-living in 150 elderly fallers (age: 76.5 ± 6.3 years, 37.6% men). In both settings, features were extracted from a lower-back accelerometer. In the real-world setting, subjects were asked to wear the device for 1 week and pre-processing detected 30-s daily-living walking bouts. A histogram of all walking bouts was determined for each walking feature for each subject and then each subject’s typical (percentile 50, median), worst (percentile 10) and the best (percentile 90) values over the week were determined for each feature. Statistics of reliability were assessed using Intra-Class correlations and Bland-Altman plots. As expected, in-lab gait speed, step regularity, and stride regularity were worse during DTW, compared to UW. In-lab gait speed, step regularity, and stride regularity during UW were significantly higher (i.e., better) than the typical daily-living values (p < 0.001) and different (p < 0.001) from the worst and best values. DTW values tended to be similar to typical daily-living values (p = 0.205, p = 0.053, p = 0.013 respectively). ICC assessment and Bland-Altman plots indicated that in-lab values do not reliably reflect the daily-walking values. Gait values measured during relatively long (30-s) daily-living walking bouts are more similar to the corresponding values obtained in the lab during dual-task walking, as compared to usual walking. Still, gait performance during most daily-living walking bouts is worse than that measured during usual and dual-tasking in the lab. The values measured in the lab do not reliably reflect daily-living measures. That is, an older adult’s typical daily-living gait cannot be estimated by simply measuring walking in a structured, laboratory setting.

27 July 2019 in Annals of Neurology
Verified
Journal Article
Open access
Silvia Del DinSilvia Del Din
Silvia Del Din
MEMorad Elshehabi
Morad Elshehabi
BGBrook Galna
Brook Galna
MHMarkus A. Hobert
Markus A. Hobert
EWElke Warmerdam
Elke Warmerdam
WMWalter Maetzler
Walter Maetzler
Objective: Quantification of gait with wearable technology is promising; recent cross‐sectional studies showed that gait characteristics are potential prodromal markers for Parkinson disease (PD). The aim of this longitudinal prospective observational study was to establish gait impairments and trajectories in the prodromal phase of PD, identifying which gait characteristics are potentially early diagnostic markers of PD.Methods: The 696 healthy controls (mean age = 63 ± 7 years) recruited in the Tubingen Evaluation of Risk Factors for Early Detection of Neurodegeneration study were included. Assessments were performed longitudinally 4 times at 2‐year intervals, and people who converted to PD were identified. Participants were asked to walk at different speeds under single and dual tasking, with a wearable device placed on the lower back; 14 validated clinically relevant gait characteristics were quantified. Cox regression was used to examine whether gait at first visit could predict time to PD conversion after controlling for age and sex. Random effects linear mixed models (RELMs) were used to establish longitudinal trajectories of gait and model the latency between impaired gait and PD diagnosis.Results: Sixteen participants were diagnosed with PD on average 4.5 years after first visit (converters; PDC). Higher step time variability and asymmetry of all gait characteristics were associated with a shorter time to PD diagnosis. RELMs indicated that gait (lower pace) deviates from that of non‐PDC approximately 4 years prior to diagnosis.Interpretation: Together with other prodromal markers, quantitative gait characteristics can play an important role in identifying prodromal PD and progression within this phase. ANN NEUROL 2019;86:357–367