Identifying disease biomarkers and detecting hazardous, explosive, flammable, and polluting gases and chemicals with extremely sensitive and selective sensor devices remains a challenging and time-consuming research challenge. Due to their exceptional characteristics, semiconducting metal oxides (SMOxs) have received a lot of attention in terms of the development of various types of sensors in recent years. The key performance indicators of SMOx-based sensors are their sensitivity, selectivity, recovery time, and steady response over time. SMOx-based sensors are discussed in this review based on their different properties. Surface properties of the functional material, such as its (nano)structure, morphology, and crystallinity, greatly influence sensor performance. A few examples of the complicated and poorly understood processes involved in SMOx sensing systems are adsorption and chemisorption, charge transfers, and oxygen migration. The future prospects of SMOx-based gas sensors, chemical sensors, and biological sensors are also discussed.
Chronic wounds that stall at the inflammatory phase of healing may create several life-threatening complications such as tissue damage, septicemia, and organ failures. In order to prevent these adverse clinical outcomes and accelerate the wound healing process, it is crucial to monitor the wound status in real-time so that immediate therapeutic interventions can be implemented. In addition, continuous monitoring of the wound status can prevent drug overdose at the wound site, leading to on-demand and personalized drug delivery. Inflammatory mediators, such as Interleukin-6 (IL-6) and Interleukin-10 (IL-10) are promising indicators for the progression of wound healing and predictors of disease severity. Toward this end, this work reports a flexible wound patch for multiplexed monitoring of IL-6 and IL-10 at the wound site in order to provide real-time feedback on the inflammation phase of the wound. An optimized composition of gold nanoparticles integrated multiwalled carbon nanotube was demonstrated to improve sensor performance substantially. The sensor also exhibited excellent repeatable, reversible, and drift characteristics. A miniaturized Internet-of-things (IoT)-enabled potentiostat was also developed and integrated with the flexible sensor to realize a wearable system. This IoT-enabled wearable device provides a smart and cost-effective solution to improving the existing wound care through continuous, real-time, and in-situ monitoring of multiple wound biomarkers.
This paper presents a flexible tattoo sensor for real-time monitoring of gaseous ethylene released from plant leaves. To the best of our knowledge, this is the first reported plant tattoo sensor that can measure and monitor a plant hormone in situ . The tattoo sensor can be easily installed on leaves and removed when required using a stick-and-peel mechanism. Furthermore, temperature and humidity sensors were incorporated to correct the ethylene measurements based on the specific microclimate of the leaf. All sensors were chemiresistive in nature, causing variations in resistance as a result of changes in temperature, humidity, or ethylene. The ethylene sensor demonstrated a sensitivity of 0.6295 kΩ/ppm and a limit of detection of 0.13 ppm. The measurements were processed by an onboard data logger, transmitted wirelessly to the cloud, and accessed on a smartphone. Plants were subjected to multiple stressors, including water, temperature, and dark stressors, and the real-time ethylene measurements were recorded with the tattoo sensor. A statistically significant difference, characterized by p values less than 0.05, was observed between different types of stresses. Roll-to-roll fabrication of these tattoos will enable their large-scale implementation in greenhouses and agricultural fields.
Studies show that excessive loss of sweat calcium is associated with deterioration of bone mineral density in young athletes during vigorous intensity exercise. Low levels of bone mineral density cause a higher risk of bone fracture, meaning a single fall can be devastating. This work reports a smart compression sock that detects calcium levels in sweat and simultaneously scans for a fall and alerts the user accordingly. The sock is washable, and the device is removable using a Velcro pad attached to the inner side of the sock. An electrochemical sensor detects the calcium levels, while a tri-axial accelerometer detects a fall event. When paired with a fall detection algorithm, the accelerometer quickly determines if a fall has occurred based on the differential acceleration. The calcium and fall detection units are interfaced with a microcontroller that sends the information to a user interface platform via the Blynk IoT cloud. If the calcium level is above/below the critical value or a fall is detected, a notification along with the user's GPS location is sent to authorized emergency contacts so that the user can be attended immediately. In addition, the electronic components were soldered onto a flexible printed circuit board. Such an integrated flexible system will allow continuous monitoring of athletes to drive just-in-time intervention.
This work presents the development of leaf-FIT: a multiplexed electrochemical sensor on a flexible substrate for real-time and in situ monitoring of phytohormones in the leaves of a living plant. Salicylic acid is a key signaling phytohormone, the elevated levels of which denote crop stresses. The sensor was demonstrated to effectively measure the salicylic acid concentrations in the leaves of a bell pepper plant under water and light stresses. The salicylic acid levels measured with our sensor demonstrated good agreement with the values from Fourier Transform Infrared Spectroscopy. As phytohormone signaling is a plant’s first response to environmental stresses, their real-time monitoring with the presented in-situ sensor can help producers in making informed decision about timely intervention.
Strain-insensitive wearable sensors have garnered substantial attention owing to their high precision sensing irrespective of body movements such as bending, stretching, and twisting motions. This work reports integrated, strain-insensitive pH and temperature sensors fabricated on a biaxially stretchable kirigami structure to quantitively measure the sweat pH levels and body temperature. Notably, an impressive strain-invariant response was demonstrated by the pH and temperature sensors under an applied biaxial tensile strain up to 220% and torsional strain up to 360°. By depicting an excellent combination of cost-effective fabrication, flexible kirigami structure, breathable notches, high linearity of response, and skin conformity, our device will open a promising new route in the application of skin-inspired wearable sensors.