Sparsh Jain

Dr. Sparsh Jain

Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Sparsh JainSparsh Jain
Sparsh Jain
Miguel A. PerezMiguel A. Perez
Miguel A. Perez
In-vehicle physiological sensing is emerging as a vital approach to enhancing driver monitoring and overall automotive safety. This pilot study explores the feasibility of a pressure-based system, repurposing commonplace occupant classification electronics to capture respiration signals during real-world driving. Data were collected from a driver-seat-embedded, fluid-filled pressure bladder sensor during normal on-road driving. The sensor output was processed using simple filtering techniques to isolate low-amplitude respiratory signals from substantial background noise and motion artifacts. The experimental results indicate that the system reliably detects the respiration rate despite the dynamic environment, achieving a mean absolute error of 1.5 breaths per minute with a standard deviation of 1.87 breaths per minute (9.2% of the mean true respiration rate), thereby bridging the gap between controlled laboratory tests and real-world automotive deployment. These findings support the potential integration of unobtrusive physiological monitoring into driver state monitoring systems, which can aid in the early detection of fatigue and impairment, enhance post-crash triage through timely vital sign transmission, and extend to monitoring other vehicle occupants. This study contributes to the development of robust and cost-effective in-cabin sensor systems that have the potential to improve road safety and health monitoring in automotive settings.

8 October 2024 in Journal of Safety Research
Verified
Journal Article
Closed access
PTPaolo Terranova
Paolo Terranova
SLShu-Yuan Liu
Shu-Yuan Liu
Sparsh JainSparsh Jain
Sparsh Jain
JEJohan Engström
Johan Engström
MPMiguel A. Perez
Miguel A. Perez

27 September 2023 in Accident Analysis & Prevention
Verified
Journal Article
Closed access
JVJacob T. Valente
Jacob T. Valente
Sparsh JainSparsh Jain
Sparsh Jain
AAArush Amin
Arush Amin
MPMiguel A. Perez
Miguel A. Perez

25 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
KLKyle Quentin Lepage
Kyle Quentin Lepage
Sparsh JainSparsh Jain
Sparsh Jain
AKAndrew Kvavilashvili
Andrew Kvavilashvili
MWMark Witcher
Mark Witcher
SVSujith Vijayan
Sujith Vijayan
A large number of human intracranial EEG (iEEG) recordings have been collected for clinical purposes, in institutions all over the world, but the vast majority of these are unaccompanied by EOG and EMG recordings which are required to separate Wake episodes from REM sleep using accepted methods. In order to make full use of this extremely valuable data, an accurate method of classifying sleep from iEEG recordings alone is required. Existing methods of sleep scoring using only iEEG recordings accurately classify all stages of sleep, with the exception that wake (W) and rapid-eye movement (REM) sleep are not well distinguished. A novel multitaper (Wake vs. REM) alpha-rhythm classifier is developed by generalizing K-means clustering for use with multitaper spectral eigencoefficients. The performance of this unsupervised method is assessed on eight subjects exhibiting normal sleep architecture in a hold-out analysis and is compared against a classical power detector. The proposed multitaper classifier correctly identifies 36±6 min of REM in one night of recorded sleep, while incorrectly labeling less than 10% of all labeled 30 s epochs for all but one subject (human rater reliability is estimated to be near 80%), and outperforms the equivalent statistical-power classical test. Hold-out analysis indicates that when using one night’s worth of data, an accurate generalization of the method on new data is likely. For the purpose of studying sleep, the introduced multitaper alpha-rhythm classifier further paves the way to making available a large quantity of otherwise unusable IEEG data.

6 March 2023
Verified
Book Chapter
Closed access
ASAbhijit Sarkar
Abhijit Sarkar
Sparsh JainSparsh Jain
Sparsh Jain
JSJeremy Sudweeks
Jeremy Sudweeks
MPMiguel Perez
Miguel Perez
Driver behavior often plays a key role in roadway safety. Distracted driving, in particular, has been proven to be one of the major reasons for crashes and near crashes. This study suggests that the criticality of a rear end event depends on the brake reaction time (BRT) of the driver. Therefore, distraction poses a greater threat in such events. Evidence accumulation model, which uses looming of the lead vehicle as main stimuli, has shown significant success in estimating drivers’ BRTs. Also, it is often argued that drivers collect evidence for braking through peripheral vision, especially during off-road glances, and transition to forward. However, there is limited work to develop a comprehensive model that can effectively model how drivers accumulate evidences during gaze away from forward. In this chapter, we have modeled evidence accumulation as a function of gaze eccentricity for off-road glances while approaching safety critical events. The model is tested with real-world crash and near-crash event data from the Second Strategic Highway Research Program 2 naturalistic study. Our model integrates human gaze, scene dynamics, and safety together. Finally, this chapter discusses typical distraction that has caused external distraction.

30 June 2018 in British Journal of Healthcare and Medical Research
Verified
Journal Article
Open access
PDF file
Sparsh JainSparsh Jain
Sparsh Jain
TBTapan Krishna Biswas
Tapan Krishna Biswas
RBRajib Bandyopadhay
Rajib Bandyopadhay
We introduce a highly accurate method of diagnosing the various pathological conditions that might exist in a subject’s brain, like edema, multiple sclerosis (Tumefactive, Relapsing-remitting, secondary-progressive, primary-progressive and progressive-relapsing), glioma, glioblastoma and metastases. These show up on conventional MRI scans, but it is often difficult to identify the exact type of the pathology from the grayscale image. We employ the use of Support Vector Machines (SVM) to work on the MR Spectroscopy [6, 12] data and correctly identify the condition-especially in seemingly vague cases where radiologists cannot rule out high uncertainty in their conclusion. The SVM trains on data sets collected for different patients and optimizes its hyperplanes based on eight input variables – T2, CHO, ADC, CR, CHO/NAA, CR/NAA, LIP/LAC, MI, CH/CR, T2 periphery [6] and Refractive index. Refractive index is an additional parameter which we include to get better boundary lines and accuracy, as shown in our prior works [10]. We test this SVM on a set of 19 patients’ data and achieve 100% accuracy in predictions. The training and testing is carried out in MATLAB.