Isteaque Ahmed

Isteaque Ahmed

Auto-generated profile, based on publicly available information

Isteaque Ahmed


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
IAIsteaque Ahmed
Isteaque Ahmed
Katherine SullivanKatherine Sullivan
Katherine Sullivan
APAashish Priye
Aashish Priye
Stereolithography based 3D printing of microfluidics for prototyping has gained a lot of attention due to several advantages such as fast production, cost-effectiveness, and versatility over traditional photolithography-based microfabrication techniques. However, existing consumer focused SLA 3D printers struggle to fabricate functional microfluidic devices due to several challenges associated with micron-scale 3D printing. Here, we explore the origins and mechanism of the associated failure modes followed by presenting guidelines to overcome these challenges. The prescribed method works completely with existing consumer class inexpensive SLA printers without any modifications to reliably print PDMS cast microfluidic channels with channel sizes as low as ~75 μm and embedded channels with channel sizes as low ~200 μm. We developed a custom multi-resin formulation by incorporating Polyethylene glycol diacrylate (PEGDA) and Ethylene glycol polyether acrylate (EGPEA) as the monomer units to achieve micron sized printed features with tunable mechanical and optical properties. By incorporating multiple resins with different mechanical properties, we were able to achieve spatial control over the stiffness of the cured resin enabling us to incorporate both flexible and rigid components within a single 3D printed microfluidic chip. We demonstrate the utility of this technique by 3D printing an integrated pressure-actuated pneumatic valve (with flexible cured resin) in an otherwise rigid and clear microfluidic device that can be fabricated in a one-step process from a single CAD file. We also demonstrate the utility of this technique by integrating a fully functional finger-actuated microfluidic pump. The versatility and accessibility of the demonstrated fabrication method have the potential to reduce our reliance on expensive and time-consuming photolithographic techniques for microfluidic chip fabrication and thus drastically lowering our barrier to entry in microfluidics research.

8 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
EDElijah Ditchendorf
Elijah Ditchendorf
IAIsteaque Ahmed
Isteaque Ahmed
JSJoseph Sepate
Joseph Sepate
APAashish Priye
Aashish Priye
Molecular tests for infectious diseases and genetic anomalies, which account for significant global morbidity and mortality, are central to nucleic acid analysis. In this study, we present a digital droplet LAMP (ddLAMP) platform that offers a cost-effective and portable solution for such assays. Our approach integrates disposable 3D-printed droplet generator chips with a consumer smartphone equipped with a custom image analysis application for conducting ddLAMP assays, thereby eliminating the necessity for expensive and complicated photolithographic techniques, optical microscopes, or flow cytometers. Our 3D printing technique for microfluidic chips facilitates rapid chip fabrication in under 2 h, without the complications of photolithography or chip bonding. The platform’s heating mechanism incorporates low-powered miniature heating blocks with dual resistive cartridges, ensuring rapid and accurate temperature modulation in a compact form. Instrumentation is further simplified by integrating miniaturized magnification and fluorescence optics with a smartphone camera. The fluorescence quantification benefits from our previously established RGB to CIE-xyY transformation, enhancing signal dynamic range. Performance assessment of our ddLAMP system revealed a limit of detection at 10 copies/μL, spanning a dynamic range up to 104 copies/μL. Notably, experimentally determined values of the fraction of positive droplets for varying DNA concentrations aligned with the anticipated exponential trend per Poisson statistics. Our holistic ddLAMP platform, inclusive of chip production, heating, and smartphone-based droplet evaluation, provides a refined method compatible with standard laboratory environments, alleviating the challenges of traditional photolithographic methods and intricate droplet microfluidics expertise.

28 June 2026 in Journal of Chemical Theory and Computation
Verified
Journal Article
Open access
IAIsteaque Ahmed
Isteaque Ahmed
SFStephen J. Fox
Stephen J. Fox
CMC. Mark Maupin
C. Mark Maupin
OTOreste Todini
Oreste Todini
DADilnoza Amirkulova
Dilnoza Amirkulova
Surfactants found in consumer products can compromise eye corneal membrane integrity upon accidental exposure. Traditional in vitro and in vivo approaches to evaluate membrane–surfactant interaction pose experimental limitations such as species variability, reproducibility, and most often do not provide the overall picture. These limitations motivate the use of in silico models to study phenomena like cellular disruption assays caused by surfactants at the molecular scale. In this work, coarse-grained molecular dynamics simulations have been employed to investigate how nonionic alcohol ethoxylate (AE) and anionic surfactant alcohol ethoxy sulfate (AES) interact with lipid bilayer liposomes that mimic corneal epithelial cell membranes. The spherical liposome is composed of 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-di(9Z-octadecenoyl)-sn-glycero-3-phosphoethanolamine (DOPE), 1,2-di(9Z-octadecenoyl)-sn-glycero-3-phospho-l-serine (DOPS), and cholesterol, resembling the composition of the corneal epithelial cells’ membrane bilayer. The simulation consisted of varying degrees of representative surfactant compositions and two initial types of surfactant configurations within or outside the liposome. Our results reveal that both surfactants induce outer leaflet bulging, agreeing with membrane solubilization models. The more highly ethoxylated surfactant, AE, caused more consistent inner leaflet disruption than AES, resulting in significantly more water permeation and membrane thinning. In addition, both surfactants increase the lateral diffusion of lipids within the membrane layers, with higher ethoxylated AE showing a stronger effect than AES. This study demonstrates how surfactant structure and localization influence bilayer membrane integrity, offering mechanistic insights into the irritation potential, thus guiding the rational design of effective surfactant-based formulations.