The winding factor is an operand in order to consider the effect of winding distribution and chording on the spatial distribution of the magnetic field in the air gap of synchronous and induction machines. The sinusoidal functions for winding factor calculation presented in literature are not defined and valid for every irregular winding, e.g., single-layer fractional-slot, combined star-delta, multilayer (greater than two), and asymmetrical windings. Although the summation of induced voltage phasors (star of slots) is the most accurate method, asymmetrical windings require to be decomposed in symmetrical components. In this paper, in addition to deriving the symmetrical components for asymmetrical multiphase windings, the analytical formulation is presented to relate the harmonic content of winding functions to winding factors. The harmonic leakage factor is accurately formulated from the winding function instead of the Görges diagram without the need for summing up an infinite number of normalized winding factors quadratically. Without restriction of the number of layers and the distribution of the winding, including full-pitch, chorded and fractional-slot symmetrical and asymmetrical windings, the suggested analysis method is validated with the star of slots and sinusoidal functions of distribution and pitch factors, where applicable.
12 April 2017 in IEEE Transactions on Industry Applications
Combined star–delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor windings, and thus to an increased efficiency. However, compared with an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive forces in the star and the delta parts of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency for induction motors equipped with combined star–delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive forces in the star and delta parts. To check the analysis’ validity, an experimental test is reported both on a cage induction motor equipped with a combined star–delta winding in the stator and on a reference motor with the same core, but with a classical three-phase winding.
21 August 2017 in IEEE Transactions on Energy Conversion
The combined star-delta winding has been attracting the attention of industry because of its potential to improve the efficiency of electrical machines. In order to show the efficiency benefits of this type of winding, many authors have used methods to determine the improvements in winding factors, published in different papers, which have not been validated yet. Some of these methods contradict each other. Furthermore, as a demerit of this winding, a unidirectional rotation has been reported. In this paper, a set of new formulas to calculate the winding factors for combined star-delta windings is proposed. In order to check the validity of the proposed formulas, a 2-D FEM and experimental tests on a salient pole synchronous machine are presented, which allows different combined star-delta winding connections. In contrast to other publications, the measurements show that combined windings can be applied for both directions of rotation without any problems.
13 December 2018 in IEEE Transactions on Industrial Electronics
In order to improve the efficiency and to reduce the field amplitudes of spatial harmonics influencing noise and vibration of electrical machines, three- and five-phase combined star-polygon windings have been suggested in the literature. Besides, the efficiency of an electrical machine is dependent on the fundamental winding factor and the noise/vibration level is related to the winding factors of some higher/lower harmonics. However, there is no systematic method to calculate the winding factor of each spatial harmonic for a multiple topology. This paper deals with proposing different topologies of multiple series multiphase combined star-polygon windings and accordingly with the calculation methods of winding factors for all spatial harmonics and the harmonic leakage factor. The results of winding function approach and symmetrical components of electromotive forces (EMFs) are perfectly in compliance with each other, provided that the fast Fourier transform (FFT) analysis is sufficiently accurate. The results obtained from measurements on an unskewed electrically excited synchronous machine are applied for validating the results given by the sum of EMFs and the proposed calculation formula. The sum of EMFs, considering just one set of a multiple topology, can give the same results as the proposed winding analysis methods for the fundamental or the slot harmonic winding factors.
Combined star-delta windings in electrical machines result in a higher fundamental winding factor and cause a smaller spatial harmonic content. This leads to lower I2R losses in the stator and the rotor winding and thus to an increased efficiency. However, compared to an equivalent six-phase winding, additional spatial harmonics are generated due to the different magnetomotive force in the star and delta part of the winding. In this paper, a complete theory and analysis method for the analytical calculation of the efficiency of induction motors equipped with combined star-delta windings is developed. The method takes into account the additional harmonic content due to the different magnetomotive force in the star and delta part. To check the analysis' validity, an experimental test is reported both on a cage induction motor equipped with a combined star-delta winding in the stator and on a reference motor with the same core but with a classical three-phase winding.
13 May 2016 in IEEE Transactions on Industry Applications
An improved model for calculating the current distribution of salient pole synchronous machines with internal faults in the stator winding is established using the multiloop method. For this purpose, good knowledge of the time-depending inductances is necessary. In this paper, a calculation method is presented to determine the inductances of a salient pole synchronous machine based on the voltage equation of a single coil in the stator winding, in particular, the mutual- and self-inductances of the stator coils, the mutual inductances between the stator coils and the field winding, the self-inductance of the field winding, the mutual inductance between the stator coils and the damper loops, the mutual inductance between the field winding and the damper loops, as well as the mutual inductance between the damper loops. The method presented here considers the analytical calculation of the magnetic flux density based on the magnetomotive force and the time-depending air-gap permeance function of the salient pole synchronous machine. The analytical approach has been validated with the finite-element method and experimental results for two different salient pole synchronous motors.