Krastin Yordanov

Dr. Krastin Yordanov

Thermal Engineering, Technical University of Varna, Varna, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2019 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Penka ZlatevaPenka Zlateva
Penka Zlateva
Krastin YordanovKrastin Yordanov
Krastin Yordanov
The operation of an air-to-water heat pump system providing space heating production for an administrative building in Varna has been explored. For this purpose, discontinuous operational mode of the heat pump system during wintertime is considered. Study has been performed by use of real values for external ambient temperature and operating characteristics of the heat pump system. The seasonal efficiency of the heat pump operation has been calculated. Also, the minimal external ambient temperature until the heat pump may work in heating regime and operation duration at outdoor air temperatures higher than the design air temperature can be determined. The economic analysis of the heat pump system exploitation has been made finally.

12 July 2021 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Penka ZlatevaPenka Zlateva
Penka Zlateva
Angel K. TerzievAngel K. Terziev
Angel K. Terziev
Krastin YordanovKrastin Yordanov
Krastin Yordanov
The focus of the present study is a small biogas power plant for anaerobic fermentation of several types of animal waste raw materials used for biogas production. The impact of some of the characteristics of substances such as composition, temperature, humidity, and pH of the mixture in the bioreactor has been considered. The above is vital for optimizing the fermentation process, and also to improve the biogas production process. The plant is located in Northeastern Bulgaria and the raw liquid manure is supplied by several neighboring small farms. The annual quantities of raw waste are as follows: cow manure - 1252 t / a; chicken manure - 427 t / a and pig manure - 639 t / a. The manure is collected in a preliminary tank and then pumped to the bioreactor. The fermenter itself is a hermetically sealed and thermally insulated tank where constant temperature is maintained. It is equipped with a stirring system, which helps the mixing and homogenization of the substrate. The tests were performed during three charges of the installation. The fermentation takes approximately 23 up to 25 days. The experiments were performed during the summer and autumn seasons when the ambient air temperature varies from 28 to 45 °C. The biogas can be used as an energy carried as the obtained organic fertilizer is suitable for agriculture purposes.

1 December 2020 in Civil and Environmental Engineering
Verified
Journal Article
Open access
PDF file
RPRositsa Petkova-Slipets
Rositsa Petkova-Slipets
Krastin YordanovKrastin Yordanov
Krastin Yordanov
Penka ZlatevaPenka Zlateva
Penka Zlateva
This research aims at comparing the thermal performance of walls made from traditional and alternative building materials. The experimental study involves five types of walls were studied based on perforated ceramic bricks and a mixture of clay, sand with various straw proportions. Specialized software and the finite element method (FEA) were employed for modelling of the thermal processes and their visualization for the different types of walls. A simulation modelling algorithm was developed. The models developed show very good convergence of the results and provide for subsequent design and thermal calculation of constructions made by environmentally friendly materials.

1 June 2020
Verified
Conference Paper
Closed access
Penka ZlatevaPenka Zlateva
Penka Zlateva
Krastin YordanovKrastin Yordanov
Krastin Yordanov
ATAdriana Tudorache
Adriana Tudorache
LCLiviu Marius Cirtina
Liviu Marius Cirtina
This paper presents an analysis of energy resources in Bulgaria and Romania. The aim of this study is to justify the need for energy mix in the energy system of Romania and Bulgaria. There is a shift from the traditional energy pillars, such as coal-fired power plants, which were the main electricity producer, to an energy sector where hydropower and other renewable energy sources provide the largest part of electricity generation. Romania and Bulgaria cannot cope with a single source of energy to meet their own energy and environmental objectives, and to guarantee sufficient stability and reliability of supply. Therefore, it is clear that the energy mix is necessary. This study can help in developing projects related to the two countries' energy strategy.

1 June 2018
Verified
Conference Paper
Closed access
Krastin YordanovKrastin Yordanov
Krastin Yordanov
Penka ZlatevaPenka Zlateva
Penka Zlateva
IHIliya Hadzhidimov
Iliya Hadzhidimov
ASAneliya Stoyanova
Aneliya Stoyanova
The subject of this paper is a temperature device for measuring 16 temperatures with thermocouples type K in the temperature range from 0 to 1250°C, called “high temperature module for 16 thermocouples”. For this ARDUINO-based device, experiments were carried out on electrically resistive furnaces, with significant errors in temperature measurement inside the furnace. The work is a comparison of the mathematical transformation in the amplifier and its improvement. The design of the module, the experimental study of the module and the results of the tests are described.

9 January 2025 in Eng
Verified
Journal Article
Open access
PDF file
Penka ZlatevaPenka Zlateva
Penka Zlateva
Angel K. TerzievAngel K. Terziev
Angel K. Terziev
Krastin YordanovKrastin Yordanov
Krastin Yordanov
MIMartin Ivanov
Martin Ivanov
BSBorislav Nikolov Stankov
Borislav Nikolov Stankov
The presented paper analyzes the impact of limestone dust accumulation on photovoltaic (PV) panel performance, focusing on the specific surrounding conditions near quarries. The results from the performed field measurements show that high concentrations of limestone dust accumulate significantly faster in these areas, and a hard layer is formed in the presence of moisture. This layer of dust is resistant to removal, even in moderate precipitation and winds with speeds between 6 and 9 m/s, making it a significant problem for the long-term performance of the systems. The analysis revealed that the lack of systematic cleaning of the panels leads to a drop in efficiency of over 20%, with this loss pointedly limiting the return on investment. This study highlights the need for innovative maintenance approaches, such as regular cleaning, use of special coatings and adapting designs to specific environmental conditions. This is essential for the development of strategies to manage, maintain and improve PV systems in areas with high levels of dust pollution.