ZEYNEP OZKURT-KAYAHAN

Prof. Dr. ZEYNEP OZKURT-KAYAHAN

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in Journal of Oral Implantology
Verified
Journal Article
Closed access
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
Titanium and titanium alloys are widely used for fabrication of dental implants. Because of potential immunologic and possible esthetic compromises with titanium implants, novel implant technologies are being developed. However, these novel technologies must maintain the characteristics that provide titanium implants with their high success rates. Zirconia implants were introduced into dental implantology as an alternative to titanium implants. Zirconia seems to be a suitable implant material because of its toothlike color, mechanical properties, biocompatibility, and low plaque affinity. The aim of this study is to review clinical and research articles conducted on zirconia dental implants, compare them with titanium dental implants, and provide information on zirconia dental implant osseointegration and mechanical strength. Zirconia dental implants have the potential to become alternative dental implants to titanium dental implants, but they are not yet in routine clinical use.

1 December 2011 in Photomedicine and Laser Surgery
Verified
Journal Article
Closed access
HAHakan Akın
Hakan Akın
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
OKOmer Kırmalı
Omer Kırmalı
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
AOAli Kemal Ozdemir
Ali Kemal Ozdemir
Objective: The aim of this study was to evaluate the effect of different surface treatments; sandblasting, Er:YAG, Nd:YAG, or CO 2 laser irradiation on the shear bond strength (SBS) of zirconia ceramic to dentin. Background data: Zirconia is not properly luted with resin cements. Various surface treatment methods have been suggested for zirconia to obtain high bond strength to resin cements. There is no study that compared the effect of different laser types (Er:YAG, Nd:YAG, CO 2 ) with sandblasting on SBS between zirconia and dentin. Methods: One hundred and twenty human maxillary third molar teeth were sectioned 3 mm below the occlusal surfaces, embedded in a metal ring with autopolymerizing acrylic resin, and stored in distilled water at 37 0 C. One hundred and twenty disc-shaped zirconia specimens were fabricated (6 mm in diameter and 4 mm in thickness), and randomly assigned to six groups ( n =20): Group 1, untreated (control); Group 2, sandblasted; Group 3, Er:YAG laser irradiated; Group 4, Nd:YAG laser irradiated with contact; Group 5, Nd:YAG laser irradiated with non-contact; Group 6, CO 2 laser irradiated. They were cemented onto the dentin with dual-cured resin cement (Variolink ® ). After they were stored in distilled water at 37 0 C for 24 h, the SBS test was performed at a crosshead speed of 1 mm/min. The fractured specimens were examined under a stereomicroscope to evaluate the fracture pattern. Results: Results of this study did not show statistically significant differences between Groups 1 and 2, or among Groups 3, 4 and 5. The lowest SBS was recorded in Group 6 (CO 2 laser), and the highest SBS was recorded in Group 4 (Nd:YAG laser with contact), followed by Group 3 (Er:YAG laser). The adhesive failure mode was predominantly observed in Groups 2, 3, 5, and 6. Group 1 showed 45% mixed failure and Group 4 showed 50% mixed failure. Conclusions: This study shows that Er:YAG and Nd:YAG laser treatment increased the bond strength of zirconia compared to sandbasting and CO 2 laser treatment.

6 January 2010 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu

1 January 2010 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
UIUfuk Iseri
Ufuk Iseri
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
Cast metal post-core systems have a long history of successful use because of their superior physical properties. However, their high elastic modulus can cause stress concentrations within the surrounding radicular dentin, resulting in root fractures. Moreover, the increasing demand for more esthetically appealing and biocompatible restorations has led to the development of tooth-colored, translucent, metal-free post-core systems. Notably, prefabricated zirconia ceramic post systems have been introduced to satisfy this trend toward a heightened awareness of esthetics, whereby the translucency of all-ceramic crowns can be successfully maintained with the use of ceramic post-core materials. Owing to the keen interest in and widespread use of zirconia ceramic post systems, many in vitro studies on zirconia posts have been published in the last 15 years. The aim of this article was to present data about the retention, fracture resistance, microleakage, light transmission, esthetic advantages, and radiodensity of zirconia posts. Two clinical survival rate studies were also presented. Based on the results of these studies, zirconia posts have been shown to improve the esthetic quality of all ceramic crowns and thus their usage is recommended. Apart from literature review, a case report in which a fractured fiber post was replaced with a custom-made zirconia post was also presented.

1 January 2010 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
AÜAhmet Ünal
Ahmet Ünal
The bond strength between veneering ceramic and zirconia framework is the weakest link in the layered structure. To investigate the shear bond strength (SBS) of veneering ceramics to zirconia, four types of zirconia ceramics (Zirkonzahn, Cercon, Lava, DC-Zirkon) were selected. For each zirconia system, 30 disk specimens were layered with IPS e.max Ceram, Vita VM9, and a manufacturer-recommended veneering ceramic. SBS test was conducted, and fracture surface analysis was also performed to determine the failure modes. One-way ANOVA, two-way ANOVA, and Tukey's HSD tests were used to analyze the data. On shear bond strength between zirconia and their recommended veneering ceramics, statistically significant differences were observed among the different zirconia systems (p<0.001). DC-Zirkon exhibited the highest SBS value (40.49±8.43 MPa), followed by Lava (27.11±2.72 MPa), Zirkonzahn (24.46±3.72 MPa), and Cercon (20.19±5.12 MPa). On shear bond strength to IPS e.max Ceram and Vita VM9, significantly lower (p0.05). In conclusion, the bonding of manufacturer-recommended veneering ceramic to the zirconia framework differed according to zirconia type.

1 January 2014 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
CTCeyda Özçakır Tomruk
Ceyda Özçakır Tomruk
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
KŞKemal Şençift
Kemal Şençift
The purpose of this study was to evaluate the patients' knowledge on dental implants in a Turkish subpopulation. Five hundred twenty seven Turkish adults referred to Yeditepe University Faculty of Dentistry, Istanbul, Turkey, were presented with a questionnaire including 20 questions regarding the level of information and awareness about the dental implants. The data were collected and statistical analyses were performed with Chi square test to compare the descriptive data. Among 527 subjects, 54% were female and 46% were male with a mean age of 42.2 years. The rate of patients' implant awareness was 27.7%. When the patients were questioned about the treatment options for rehabilitation of tooth missing, 60.9% of patients were informed about fixed partial denture, followed by conventional complete denture (32.5%) and removable partial denture (24.9%). Six percent reported that they were very well informed about the dental implants whereas 48.2% were poorly informed. The information sources of the implants were from the dentist (44.5%), printed media (31.6%) and friends and acquaintances (17.3%), respectively. Sixteen percent of the population believed that their implants would last forever. The dentists should give more detailed information to the patients about dental implants and tooth-supported fixed partial dentures in the future.