Hacen Khlaifi

Dr. Hacen Khlaifi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in Results in Optics
Verified
Journal Article
Open access
HKHacen Khlaifi
Hacen Khlaifi
AZAmira Zrelli
Amira Zrelli
TETahar Ezzedine
Tahar Ezzedine

1 December 2023 in Wireless Personal Communications
Verified
Journal Article
Open access
PDF file
JHJeridi Mohamed hechmi
Jeridi Mohamed hechmi
HKHacen Khlaifi
Hacen Khlaifi
ABAmine Bouatay
Amine Bouatay
TETahar Ezzedine
Tahar Ezzedine

1 January 2026 in Journal of Sensors
Verified
Journal Article
Open access
HKHacen Khlaifi
Hacen Khlaifi
AZAmira Zrelli
Amira Zrelli
Multiparameter fiber optic sensors face a fundamental challenge: cross‐sensitivity between measured parameters compromises accuracy and limits practical deployment. We present a triple‐cavity cascade architecture combining two fiber Bragg gratings (FBGs) and a Fabry–Pérot interferometer (FPI) for the simultaneous measurement of temperature, pressure, and humidity with exceptional numerically‐predicted discrimination performance. The system exploits complementary sensitivity models in a sensitivity matrix with determinant 2.59 and condition number 644, enabling robust parameter recovery through matrix inversion enhanced by a 3–8–8–3 neural network. A comprehensive numerical simulation over the full operating ranges (0–100°C, 100–500 kPa, 5–95%RH) demonstrates simulated accuracies of ±0.011°C in temperature, ±0.012 kPa in pressure, and ±0.021%RH in humidity, with all six cross‐sensitivity pairs suppressed below 1%. This represents a numerically predicted improvement potential of 5×–15× compared to existing two‐parameter systems and is, to our knowledge, the first numerically demonstrated three‐parameter design based on rigorous theoretical analysis. Error budget analysis identifies coating hysteresis (80%) as the primary accuracy limiter for humidity, while wavelength noise (72%) and phase noise (62%) dominate the temperature and pressure uncertainties, respectively. Dynamic response tests over 100 time steps confirm root mean square error (RMSE) values of 0.071°C, 0.313 kPa, and 0.244%RH under simultaneous sinusoidal, step, and random parameter variations. Although experimental validation remains pending, the rigorous theoretical framework provides a model for next‐generation environmental sensing with applications in aerospace monitoring, industrial process control, and precision instrumentation.