Aristides Marcano Olaizola

Dr. Aristides Marcano Olaizola

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2018 in Virology Journal
Verified
Journal Article
Open access
PDF file
DKDavid Kingsley
David Kingsley
RKRobinson Kuis
Robinson Kuis
RPRafael Perez
Rafael Perez
IBIsaac Basaldua
Isaac Basaldua
PBPaul Burkins
Paul Burkins
AJAnthony Johnson
Anthony Johnson
Previous work indicated that an ultrashort pulse (USP) 425 nm laser is capable of inactivating murine norovirus (MNV: Virol. J. 11:20), perhaps via an impulsive stimulated Raman scattering (ISRS) mechanism, and does not substantially damage human plasma proteins (PLOS One 9:11). Here, further investigation of virus inactivation by laser light is performed. In this study, we evaluate whether inactivation of MNV is specific to the USP wavelength of 425 nm, or if it occurs at other visible wavelengths, using a tunable mode-locked Ti-Sapphire laser that has been frequency doubled to generate femtosecond pulses at wavelengths of 400, 408, 425, 450, 465, and 510 nm. Continuous Wave (CW) lasers are also applied. Singlet oxygen enhancers are used to evaluate the sensitivity of MNV to singlet oxygen and oxygen quenchers are used to evaluate effects on virus inactivation as compared to untreated controls. > 3 log10 inactivation of MNV pfu occurs after irradiation with an average power of 150 mW at wavelengths of 408, 425 or 450 nm femtosecond-pulsed light for 3 h. Thus results suggest that the mechanism by which a laser inactivates the virus is not wavelength-specific. Furthermore, we also show that irradiation using a continuous wave (CW) laser of similar power at 408 nm also yields substantial MNV inactivation indicating that inactivation does not require a USP. Use of photosensitizers, riboflavin, rose bengal and methylene blue that generate singlet oxygen substantially improves the efficiency of the inactivation. The results indicate a photochemical mechanism of the laser-induced inactivation where the action of relatively low power blue laser light generates singlet oxygen. Results suggest formation of short-lived reactive oxygen species such as singlet oxygen by visible laser light as the cause of virus inactivation rather than via an ISRS mechanism which induces resonant vibrations.

1 June 2007 in Applied Spectroscopy
Verified
Journal Article
Closed access
Aristides Marcano OlaizolaAristides Marcano Olaizola
Aristides Marcano Olaizola
NMN. Melikechi
N. Melikechi
We present a mode-mismatched continuous wave (cw) achromatic thermal lens experiment in which the pump beam is focused in the presence of a collimated probe beam. This scheme presents a distinct advantage over mode-matched thermal lens experimental methods in that it considerably reduces chromatic aberrations. Further, using the proposed method, we measure the near infrared spectrum of distilled water. The results are in good agreement with previous transmission measurements.

1 June 2014 in Applied Spectroscopy
Verified
Journal Article
Closed access
Aristides Marcano OlaizolaAristides Marcano Olaizola
Aristides Marcano Olaizola
SASalvador Alvarado
Salvador Alvarado
JMJunwei Meng
Junwei Meng
DCDaniel Caballero
Daniel Caballero
EME. Marín
E. Marín
RERaymond Edziah
Raymond Edziah
We developed a pump-probe photothermal lens spectrophotometer that uses a broadband arc-lamp and a set of interference filters to provide tunable, nearly monochromatic radiation between 370 and 730 nm as the pump light source. This light is focused onto an absorbing sample, generating a photothermal lens of millimeter dimensions. A highly collimated monochromatic probe light from a low-power He–Ne laser interrogates the generated lens, yielding a photothermal signal proportional to the absorption of light. We measure the absorption spectra of scattering dye solutions using the device. We show that the spectra are not affected by the presence of scattering, confirming that the method only measures the absorption of light that results in generation of heat. By comparing the photothermal spectra with the usual absorption spectra determined using commercial transmission spectrophotometers, we estimate the quantum yield of scattering of the sample. We discuss applications of the device for spectroscopic characterization of samples such as blood and gold nanoparticles that exhibit a complex behavior upon interaction with light.

7 September 2022 in Journal of Photochemistry and Photobiology B: Biology
Verified
Journal Article
Closed access
Aristides Marcano OlaizolaAristides Marcano Olaizola
Aristides Marcano Olaizola
RKRobinson Kuis
Robinson Kuis
AJAnthony Johnson
Anthony Johnson
DKDavid Kingsley
David Kingsley

25 October 2017 in Applied Spectroscopy
Verified
Journal Article
Closed access
Aristides Marcano OlaizolaAristides Marcano Olaizola
Aristides Marcano Olaizola
This work reports on photothermal lens spectra of silver nanoparticles of different dimensions in the spectral region of 370–730 nm performed using an arc-lamp-based photothermal spectrophotometer. We show that the photothermal and extinction cross-section spectra of the samples are similar for nanoparticles of reduced dimensions where scattering effects are small. The results differ substantially for nanoparticles of a diameter larger than 30 nm for which scattering becomes relevant. We demonstrate that the photothermal spectrum corresponds to the absorption component of the particle’s extinction. Photothermal spectra show a clear picture of the plasmonic peaks of the nanoparticle even in the presence of high scattering. By subtracting the photothermal component from the total extinction, we extract the scattering cross-section spectra of the nanoparticles. The technique allows determination of the absorption and scattering components of the extinction providing a better understanding of the particle’s optical properties. The results agree well with the Mie approximation, which is valid for a single spherical nanoparticle. We discuss and demonstrate the application of the method to characterize particles of arbitrary shape and dimensions.

19 January 2011 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
Aristides Marcano OlaizolaAristides Marcano Olaizola
Aristides Marcano Olaizola
FDF. Delima
F. Delima
YMYuri Markushin
Yuri Markushin
NMN. Melikechi
N. Melikechi
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.