With the recent advances in the fifth-generation cellular system (5G), enabling vehicular communications has become a demand. The vehicular ad hoc network (VANET) is a promising paradigm that enables the communication and interaction between vehicles and other surrounding devices, e.g., vehicle-to-vehicle (V2V) and vehicle-to-everything (V2X) communications. However, enabling such networks faces many challenges due to the mobility of vehicles. One of these challenges is the design of handover schemes that manage the communications at the intersection of coverage regions. To this end, this work considers developing a novel seamless and efficient handover scheme for V2X-based networks. The developed scheme manages the handover process while vehicles move between two neighboring roadside units (RSU). The developed mechanism is introduced for multilane bidirectional roads. The developed scheme is implemented by multiple-access edge computing (MEC) units connected to the RSUs to improve the implementation time and make the handover process faster. The considered MEC platform deploys an MEC controller that implements a control scheme of the software-defined networking (SDN) controller that manages the network. The SDN paradigm is introduced to make the handover process seamless; however, implementing such a controlling scheme by the introduction of an MEC controller achieves the process faster than going through the core network. The developed handover scheme was evaluated over the reliable platform of NS-3, and the results validated the developed scheme. The results obtained are presented and discussed.
People in urban regions face a daily problem finding parking slot for their vehicles. So, this study develops a network architecture based on Internet of Things platform. A system improves the efficiency of the current cloud-based smart-parking system. This study suggested a system that assists users in automatically finding a free parking space at the lowest cost. With an application, a user can request to reserve a parking slot. The application moves a driver directly into the free slot in a garage. Also, it utilizes the distance and total number of free spaces in each garage to determine the user nearest parking slot and cost. The garage slot cost will be charged by user credit once the user entered the garage or reserved a parking slot through the application. The system proposed a novel system which picks up a parking slot, reserves, and pays for it through mobile application. The proposed system can easily be deployed in the actual world.
The COVID-19 pandemic exposed critical vulnerabilities in healthcare systems worldwide, placing healthcare workers (HCWs) at severe infection risk through direct patient contact. Epidemiological data confirm that HCWs were approximately seven times more likely to develop severe COVID-19 than other occupations, with over 7000 HCW deaths recorded globally by mid-2020. This paper presents the design and laboratory proof-of-concept validation of an IoT-based remote patient-monitoring system prototype—the IoT-Based Isolation Ward Monitoring System Prototype—designed to eliminate unnecessary patient-to-HCW physical contact while maintaining continuous, real-time physiological surveillance. The system integrates multi-sensor hardware comprising an AD8232 ECG module, a MAX30100 pulse oximeter, an NTC thermistor, and an MQ-135 sensor. These sensors interface with an Arduino UNO for data acquisition, while localized edge computing is executed on a Raspberry Pi 3B. A convolutional neural network (CNN) trained on the MIT-BIH Arrhythmia Database classifies heartbeats into five distinct categories. By utilizing SMOTE resampling on 109,446 samples, the network achieves an on-device inference latency of under 200 ms. The sensor data are transmitted to a Firebase Realtime Database via an authenticated REST API, which synchronizes data across dual front-end interfaces: a LabVIEW desktop dashboard for clinical oversight and a cross-platform Flutter mobile application for mobile monitoring. End-to-end technical validation under controlled laboratory conditions confirmed round-trip cloud latencies between 300 and 800 ms, error-free threshold alert generation, and sub-second latency for the integrated chat utility. The proposed system uniquely combines hardware sensing, ML-based ECG classification, cloud storage, a LabVIEW physician dashboard, and bidirectional doctor–patient mobile communication into a single unified, low-cost platform.
1 February 2026 in Bulletin of Electrical Engineering and Informatics
The increasing demand for the internet of things (IoT) and massive machine-type communications has significantly expanded network size and complexity. Recent research indicates that 95% of network tasks are monitored manually, leading to configuration complexity, human errors, faults, downtime risks, and time consumption. Network automation emerges as a practical solution by reducing administrative overhead and enabling reliable, scalable, and self-managing networks through scripting and standardized programming languages. This paper proposes a model for automated networks using Python-based methods, specifically Paramiko, Netmiko, and the network automation and programmability abstraction layer with multivendor support (NAPALM), to configure the enhanced interior gateway routing protocol (EIGRP) within the graphical network simulator-3(GNS3) environment. The performance of the automated network was evaluated using two scenarios: with threading and without threading. Key metrics included execution time, configuration accuracy, error rates, and resource utilization. Simulation results demonstrate that the automated approach significantly outperforms manual configuration. In addition, the automated model with threading outperformed the automated model without threading, achieving execution time reductions up to 67% and 100% configuration accuracy with zero errors. These findings underscore the effectiveness of the proposed system for automating complex network tasks in large-scale IoT deployments.
Continuous remote physiological monitoring requires low-cost sensing nodes to preserve timing fidelity while maintaining secure connectivity and interpretable escalation. This study presents an engineering proof-of-concept platform centered on an ESP32-S3 with AD8232 ECG, MAX30102 PPG/SpO2, and MAX30205 contact-temperature sensing. FreeRTOS separates nominal 100 Hz ECG/PPG acquisition from network communication, and the ECG R-wave-to-peripheral-PPG-foot interval is treated as pulse-arrival time (PAT). Telemetry is transmitted over authenticated HTTPS to a Laravel platform, while a separate FastAPI service provides human-in-the-loop normal/warning/critical functional triage. The current evidence is limited to bench-top engineering operation and synthetically constructed triage scenarios; no human-participant measurements are analyzed or reported. An ethics-approved rest-exertion-recovery protocol has been prepared for a future validation stage. The present results support system integration and engineering feasibility, while physiological accuracy, PAT-to-blood-pressure calibration, respiratory-rate agreement, classifier performance, timing reliability, and battery/power characteristics remain to be established quantitatively.
Wearable seizure-detection systems can provide objective event monitoring and rapid caregiver alerting without continuous bedside observation. This study presents a resource-constrained multimodal wearable sensor platform for focal-to-bilateral tonic–clonic seizure (FBTCS) detection using edge artificial intelligence and Internet of Things (IoT) communication. The prototype integrates an ESP32-S3 microcontroller, an analog electromyography (EMG) channel, an MPU6050 inertial sensor, MAX30102 photoplethysmography, GPS, a TFT display, local vibration/buzzer outputs, and Blynk cloud telemetry. The seizure–decision path uses synchronized EMG and acceleration acquired at 100 Hz in non-overlapping 10 s windows. EMG and acceleration are resampled for compatibility with the reference feature pipeline, 13 statistical features are extracted from each modality (26 total), and an 85-tree XGBoost model is executed locally. A probability threshold of 0.85 is combined with temporal smoothing, consecutive-window confirmation, and a 60 s refractory interval. Software verification showed maximum absolute probability differences of approximately 1.19 × 10−7 for random feature-vector tests and 1.49 × 10−8 for end-to-end recorded windows relative to the Python reference. Within the reported validation record covering 2643.69 h and 18 record-labeled FBTCS events, 12 events were detected (12/18; 67% sensitivity). Precision was approximately 26%, F1-score approximately 38%, the reported false-alarm rate was 0.31 per 24 h, and median detection latency was 61.5 s. Approximately 34 false alarms are estimated from the reported false-alarm rate and evaluation duration; this is an estimated count rather than a percentage or directly observed count. Hardware, local alarm, display, GPS, and cloud communication functions passed functional integration tests. The small event count, uncertain label provenance, low precision, and long latency mean that these data support an engineering proof-of-concept only and do not establish clinical applicability.