Yingqing Lu

Dr. Yingqing Lu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2023 in Chemical Engineering Journal
Verified
Journal Article
Closed access
JJJason Jones
Jason Jones
VDViviann Do
Viviann Do
YLYingqing Lu
Yingqing Lu
RDR. Michael van Dam
R. Michael van Dam

2 October 2023 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYingqing Lu
Yingqing Lu
YHYingfang He
Yingfang He
Roger SchibliRoger Schibli
Roger Schibli
LMLinjing Mu
Linjing Mu
RDR. Michael Van Dam
R. Michael Van Dam
Copper-mediated radiofluorination has demonstrated remarkable potential in forming aromatic C–18F bonds of radioligands for positron emission tomography (PET). Achieving optimal results often requires optimization efforts, requiring a substantial amount of radiolabeling precursor and time, severely limiting the experimental throughput. Recently, we successfully showcased the feasibility of performing and optimizing Cu-mediated radiosynthesis on a high-throughput microdroplet platform using the well-known and clinically used radioligand [18F]FDOPA as an illustrative example. In our current work, we optimized the Cu-mediated synthesis of a novel monoacylglycerol lipase (MAGL) PET tracer ([18F]YH149), showing the versatility of droplet-based techniques for early stage tracer development. Across 5 days, we conducted a total of 117 experiments, studying 36 distinct conditions, while utilizing <15 mg of total organoboron precursor. Compared to the original report in which the radiochemical yield (RCY) was 4.4 ± 0.5% (n = 5), the optimized droplet condition provided a substantial improvement in RCY (52 ± 8%, n = 4) and showed excellent radiochemical purity (100%) and molar activity (77–854 GBq μmol−1), using a starting activity of 0.2–1.45 GBq. Furthermore, we showed for the first time a translation of the optimized microscale conditions to a vial-based method. With similar starting activity (0.2–1.44 GBq), the translated synthesis exhibited a comparable RCY of 50 ± 10% (n = 4) while maintaining excellent radiochemical purity (100%) and acceptable molar activity (20–46 GBq μmol−1). The successful translation to vial-based reactions ensures wider applicability of the optimized synthesis by leveraging widely available commercial vial-based synthesis modules.

10 January 2024 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYingqing Lu
Yingqing Lu
JCJeffrey Collins
Jeffrey Collins
KLKuo-Shyan Lin
Kuo-Shyan Lin
RDR. Michael Van Dam
R. Michael Van Dam
Rapid, efficient and straightforward radiosynthesis scale-up strategy for droplet-based reactions via a numbering up technique.

21 November 2022 in Journal of Chromatography A
Verified
Journal Article
Closed access
TLTravis S. Laferriere-Holloway
Travis S. Laferriere-Holloway
ARAlejandra Rios
Alejandra Rios
YLYingqing Lu
Yingqing Lu
COChelsea C. Okoro
Chelsea C. Okoro
RDR. Michael Van Dam
R. Michael Van Dam

26 September 2024 in Molecules
Verified
Journal Article
Open access
PDF file
YLYingqing Lu
Yingqing Lu
PCPhilip H. Chao
Philip H. Chao
JCJeffrey Collins
Jeffrey Collins
RDR. Michael Van Dam
R. Michael Van Dam
The radiometal gallium-68 (Ga-68) has garnered significant interest due to its convenient production via compact and widely available generators and the high performance of 68Ga-labeled compounds for positron-emission tomography (PET) imaging for cancer diagnosis and management of patients undergoing targeted radionuclide therapy. Given the short half life of Ga-68 (68 min), microfluidic-based radiosynthesis is a promising avenue to establish very rapid, efficient, and routine radiolabeling with Ga-68; however, the typical elution volume of Ga-68 from a generator (4–10 mL) is incompatible with the microliter reaction volumes of microfluidic devices. To bridge this gap, we developed a microscale cartridge-based approach to concentrate Ga-68. By optimizing cartridge design, resin type, resin mass, and eluent composition, Ga-68 was reliably concentrated from ~6 mL to ~80 µL with high recovery efficiency (>97%, n = 14). Furthermore, this method is suitable for both single- and dual-generator setups. To demonstrate suitability of the concentrated radiometal for radiolabeling, we performed microdroplet synthesis of [68Ga]Ga-PSMA-11, achieving high radiochemical yield (83 ± 11%, n = 3), excellent radiochemical purity (>99%), and high apparent specific activity (255–320 MBq/μg). The entire process, including Ga-68 concentration, radiosynthesis, purification, and formulation, was completed in 12 min. Starting with activity of 0.81–0.84 GBq, 0.51–0.64 GBq of product was produced, sufficient for multiple patient doses. This work paves the way to clinical-scale production of other 68Ga-labeled compounds using droplet microreactor methods, or high-throughput labeling optimization or compound screening of 68Ga-labeled probes using droplet reaction arrays.

1 January 2023 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
JJJason Jones
Jason Jones
VDViviann Do
Viviann Do
YLYingqing Lu
Yingqing Lu
RDR. Michael Van Dam
R. Michael Van Dam
The growing discovery and development of novel radiopharmaceuticals and radiolabeling methods requires an increasing capacity for radiochemistry experiments. However, such studies typically rely on radiosynthesizers designed for clinical batch production rather than research, greatly limiting throughput. Two general solutions are being pursued to address this: developing new synthesis optimization algorithms to minimize how many experiments are needed, and developing apparatus with enhanced experiment throughput. We describe here a novel high-throughput system based on performing arrays of droplet-based reactions at 10 μL volume scale in parallel. The automatic robotic platform can perform a set of 64 experiments in ~3 h (from isotope loading to crude product, plus sampling onto TLC plates), plus ~1 h for off-line radio-TLC analysis and radioactivity measurements, rather than the weeks or months that would be needed using a conventional system. We show the high repeatability and low crosstalk of the platform and demonstrate optimization studies for two 18F-labeled tracers. This novel automated platform greatly increases the practicality of performing arrays of droplet reactions by eliminating human error, vastly reducing tedium and fatigue, minimizing radiation exposure, and freeing up radiochemist time for more intellectually valuable pursuits.