6 April 2022 in American Journal of Otolaryngology
27 September 2023 in The Egyptian Journal of Otolaryngology
Objectives: Otoacoustic emissions (OAEs) are an important part of the audiological test battery and have many clinical uses. This study aims to determine the amplitude changes in the test–retest condition of distortion product otoacoustic emissions (DPOAEs) and transient-evoked otoacoustic emissions (TEOAEs), which are widely used in clinical settings. Design: DPOAE and TEOAE measurements were taken in 110 ears of 55 adults aged 18–35 years with normal hearing during three sessions. The repeatability of the measurements was evaluated by very short-term measurements taken 20 min after the first measurement and by short-term measurements taken 20 days after the first measurement. Results: There was no statistically significant difference between the three measurements in which DPOAE and TEOAE amplitudes were evaluated. The weakest reliability for TEOAEs was determined at frequencies of 1.0 kHz and 1.5 kHz, and the weakest reliability for DPOAEs was determined at 6728 Hz. Conclusions: The current findings indicate that DPOAE and TEOAE measurements are reliable for monitoring cochlear function over time. The data obtained from this study could help clinicians correctly interpret OAE changes and distinguish between physiological and pathological changes.
18 May 2025 in Brain and Behavior
Objective: The aim was to investigate the impact of visual tasks on acoustic reflex thresholds (ARTs) and AR latencies (ARLs) during AR measurements.Methods: A total of 31 participants (17 female, 14 male; mean age: 20.3 ± 1.8 years) with normal hearing and Type A tympanograms were included. ARTs and latencies were measured using a 226 Hz probe tone under five distinct conditions: (1) resting with no visual task, (2) eyes comfortably closed, (3) fixed gaze on a stationary object, (4) saccadic eye movements, and (5) optokinetic eye movements. Data were analyzed using repeated measures ANOVA with Bonferroni correction applied for post hoc comparisons.Results: ARTs were significantly lower in the condition of eyes closed compared to fixed gaze, at both 1 and 2 kHz (p < 0.05). ARLs at 500 Hz were significantly shorter in the condition of fixed gaze compared to saccadic eye movements (p < 0.05). A significant interaction between frequency and condition was observed for ARTs, indicating frequency‐specific modulation by visual tasks, whereas no significant frequency and condition interaction was found for ARLs.Conclusion: Visual tasks have a measurable effect on ARTs and latencies, likely due to cross‐modal interactions between the auditory and visual systems. These results highlight the importance of standardizing visual and attentional conditions during clinical AR testing. Further research is warranted to elucidate the underlying neural mechanisms and their clinical implications.
1 January 2025 in Journal of the American Academy of Audiology
Background: Labyrinthitis, an inner ear infection affecting the membranous labyrinth, typically presentswith symptoms such as dizziness, nausea, vomiting, tinnitus, and hearing loss. However, there is limitedepidemiological data on this condition.Purpose: This case report presents the results of audiovestibular evaluation and vestibular rehabilitationregarding unilateral sudden hearing loss and acute vestibular syndrome caused by rare labyrinthitisin a pediatric patient.Research Design: This is a case report.Study Sample: The study sample included a 5-year-old girl with unilateral sudden hearing loss andacute vestibular syndrome.Results: The patient with labyrinthitis, diagnosed early after comprehensive audiological and vestibularevaluation, benefited from medical treatment and vestibular rehabilitation.Conclusions: This report objectively focuses on the importance of early medical treatment, regularaudiovestibular follow-up, and vestibular rehabilitation in a pediatric patient with labyrinthitis.
28 December 2024 in KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi
İşitme kayıplı çocuğa sahip aileler çocuğunun işitme kaybından olumsuz etkilenebilir ve bilgi edinme gereksinimi, psikoloik destek gereksinimi, ekonomik gereksinim, destek gereksinimi gibi çeşitli gereksinimlere ihtiyaç duyabilir. Ailelerin işitme kaybı, mevcut süreç ve hizmetler hakkında yeterli bilgiye sahip olmaması hizmetlere ulaşmasında gecikmeye neden olabilir. Bu durum işitme kayıplı çocukların erken tanı ve tedavi seçeneğinden mahrum kalmasına sebep olabilir. İşitme kayıplı çocuğa sahip ailelere, belirlenen gereksinimlere yönelik aile danışmanlığı hizmetlerine erişebilme imkanı sunulması gerekmektedir. Bu çalışmanın amacı, işitme kaybı yaşayan ailelerin gereksinimlerini belirleyerek aile danışmanlığı hizmetlerinin oluşturulması ve uygulamasının arttırılmasının hem aile hem de işitme kayıplı çocuk için sürecin daha sağlıklı ilerleyeceğini ortaya koyarak farkındalık oluşturmaktır.
23 September 2025 in Acta Oto-Laryngologica
The Visual Vertical, an iOS mobile application, enables a more practical implementation of the subjective visual vertical (SVV) test compared to the bucket method. To determine the effectiveness of the iOS mobile application on SVV in children. A bucket test specifically designed for SVV assessment was administered to 44 children aged 11 to 14 years. The bucket was rotated 45° from the neutral (0°) head position in both clockwise and counter-clockwise rotations. Participants were instructed to indicate the moment they perceived the line inside the bucket as vertically aligned after 10 s. Angular deviations were recorded using both a protractor and an iOS application. Each participant underwent five trials in each rotational direction, and the mean was calculated to determine the SVV deviation angle. SVV deviation angle was determined as 0.92° in clockwise rotation and 0.96° in counter-clockwise rotation in the bucket test; and as 0.97° and 1.03° in the iOS application, respectively. No statistically significant difference was observed between SVV deviation angles in both applications (p > 0.05). Visual Vertical, an iOS mobile application, offers a practical and accessible alternative to the bucket method for assessing utricular function in children.