Ryotaro Iwayama

Dr. Ryotaro Iwayama

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in International Journal of Environmental Science and Technology
Verified
Journal Article
Open access
PDF file
Norimichi SuzukiNorimichi Suzuki
Norimichi Suzuki
HNH. Nakaoka
H. Nakaoka
YNY. Nakayama
Y. Nakayama
KTK. Takaya
K. Takaya
KTK. Tsumura
K. Tsumura
CMC. Mori
C. Mori
Nowadays, people spend most of their time indoors; thus, the indoor environment greatly affects human health because of exposure to chemicals indoors. Thus, in collaboration with Japanese house builders, a list of building materials having low volatile organic compound concentrations was compiled herein. The air-quality samples from seven newly built houses (seven bedrooms and seven living rooms) were collected and tested for 64 volatile organic compounds and two aldehydes. Air samples were obtained from the house with no furniture or household goods and were sampled 1 week after construction and repeated after a month. Furthermore, the test results with a 2009 survey of indoor air quality in newly constructed houses were compared. One week after construction, the xylene, styrene, toluene, formaldehyde, and ethylbenzene concentrations were less than half the standard guideline values set in Japan. The main substances detected in the samples were 2-butanone, acetone, ethanol, ethyl acetate, butyl acetate, and undecane. The statistical significance of the changes in substance concentrations over time was examined via Wilcoxon signed-rank test. One month after construction, the concentrations of all chemical substances had undergone a statistically significant reduction, except butyl acetate. The median of total volatile organic compounds in living rooms was 291 µg/m3, and the maximum was 354 µg/m3; both were under Japan’s provisional total volatile organic compound target of 400 µg/m3. These values were significantly lower than those recorded by other researchers. This study concludes that using experimentally identified low volatile organic compound materials effectively improves the indoor air quality.

30 April 2024 in Building and Environment
Verified
Journal Article
Open access
KSKeiichi Shimatani
Keiichi Shimatani
YNYoshitake Nakayama
Yoshitake Nakayama
KTKohki Takaguchi
Kohki Takaguchi
Ryotaro IwayamaRyotaro Iwayama
Ryotaro Iwayama
KYKayo Yoda-Tsumura
Kayo Yoda-Tsumura
NSNorimichi Suzuki
Norimichi Suzuki

24 January 2025 in Preventive Medicine Reports
Verified
Journal Article
Open access
KOKazuya Ogawa
Kazuya Ogawa
KSKeiichi Shimatani
Keiichi Shimatani
Ryotaro IwayamaRyotaro Iwayama
Ryotaro Iwayama
NSNorimichi Suzuki
Norimichi Suzuki
While the relationship between higher housing cost burden and poorer mental health has been established in lower-income groups, research examining high-income populations is scarce. We aimed to examine this relationship among high-income homeowners in Japan. We conducted a cross-sectional study on 6753 Japanese homeowners in detached houses. Data were collected as part of an ongoing panel survey, from new survey respondents during Wave 2 (Jul-Sept 2023) and Wave 3 (Jan-Mar 2024). Psychological distress, measured using the Kessler 6 scale, was the dependent variable. The explanatory variable was the mortgage-to-income ratio, categorized into two and six levels. We performed modified log Poisson regression analyses, incorporating income stratification, with missing data handled by multiple imputation. For both overall respondents (PR = 1.22, 95 % CI 1.11-1.35) and the high-income group (PR = 1.23, 95 % CI 1.09-1.39), individuals with mortgage payment ratios ≥30 % were more likely to report psychological distress compared with those <30 %. While the low-income group showed a marginally similar tendency (PR = 1.21, 95 % CI 1.00-1.46), this association was not robust in the sensitivity analysis. Higher mortgage payment ratios were associated with greater psychological distress even among high-income homeowners. The impact of housing cost stress on psychological distress may be more extensive than previously recognized.

25 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Ryotaro IwayamaRyotaro Iwayama
Ryotaro Iwayama
KSKeiichi Shimatani
Keiichi Shimatani
YNYoshitake Nakayama
Yoshitake Nakayama
KTKohki Takaguchi
Kohki Takaguchi
Hiroko NakaokaHiroko Nakaoka
Hiroko Nakaoka
KSKenichi Sakurai
Kenichi Sakurai
Ventilation plays a key role in maintaining indoor air quality and reducing building-related symptoms (BRSs). Although prior studies suggest that ventilation volume and system type may influence BRSs, few have examined their combined effects in residential settings. This cross-sectional study investigated associations between ventilation volume, system type, and BRSs among 3970 residents of newly built detached houses in Japan. Data were collected in two waves in 2023, and the ventilation volume per floor area and per person was calculated from building specifications. BRSs were assessed using the MM040EA Sick House Syndrome questionnaire and analyzed using binary logistic regression stratified by system type. In air supply and exhaust systems, higher ventilation volume per person was linked to a lower prevalence of general symptoms (OR = 0.46). In exhaust-only systems, greater ventilation volume was positively associated with mucosal irritation symptoms (OR = 1.60). These findings highlight the complex relationship between ventilation and health and emphasize the importance of system type. Although air quality parameters were not measured directly, the results provide evidence based on building specifications, thereby offering insight to refine building codes, guide post-occupancy assessments, and inform preventive public health policy.