Anamika Yadav

Dr. Anamika Yadav

ELECTRICAL ENGINEERING, National Institute of Technology, Raipur, India
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015
Verified
Conference Paper
Closed access
BIBhupendra Ingre
Bhupendra Ingre
AYAnamika Yadav
Anamika Yadav
Anomalous traffic detection on internet is a major issue of security as per the growth of smart devices and this technology. Several attacks are affecting the systems and deteriorate its computing performance. Intrusion detection system is one of the techniques, which helps to determine the system security, by alarming when intrusion is detected. In this paper performance of NSL-KDD dataset is evaluated using ANN. The result obtained for both binary class as well as five class classification (type of attack). Results are analyzed based on various performance measures and better accuracy was found. The detection rate obtained is 81.2% and 79.9% for intrusion detection and attack type classification task respectively for NSL-KDD dataset. The performance of the proposed scheme has been compared with existing scheme and higher detection rate is achieved in both binary class as well as five class classification problems.

1 May 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
JJJenifer Mariam Johnson
Jenifer Mariam Johnson
AYAnamika Yadav
Anamika Yadav
This paper presents a complete protection scheme for detecting, classifying and locating the fault in HVDC transmission lines using support vector machines (SVM). SVM has been used for protective relaying application in HVAC transmission line, however very limited works have been reported for HVDC transmission line. In this work, a ±500 kV HVDC transmission system is developed in PSCAD/EMTDC and the measurement signals obtained are analyzed in MATLAB. The rectifier side AC RMS voltage, DC voltage and current on both the poles are continuously monitored, and given as input to the SVM binary classifier in order to detect the presence of fault in the line. Once a fault is detected, the SVM multi‐class classification module predicts the type of fault and the SVM regression algorithm predicts the location of fault. The feature vector used in the classification and location modules is the standard deviation of the signals over half cycle before and after the occurrence of fault. The method proposed is simple as it requires single‐end data and a direct standard deviation of one cycle data gives very accurate results. The detection and classification modules are 100% accurate whereas the fault location module has a mean error of 0.03%.

1 April 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
AYAnamika Yadav
Anamika Yadav
ASAleena Swetapadma
Aleena Swetapadma
This study aims to improve the performance of transmission line directional relaying, fault classification and fault location schemes using fuzzy system. Three separate fuzzy inference system are designed for complete protection scheme for transmission line. The proposed technique is able to accurately detect the fault (both forward and reverse), locate and also identify the faulty phase(s) involved in all ten types of shunt faults that may occur in a transmission line under different fault inception angle, fault resistances and fault location. The proposed method needs current and voltage measurements available at the relay location and can perform the fault detection and classification in about a half‐cycle time. The proposed fuzzy logic based relay has less computation complexity and is better than other AI based methods such as artificial neural network, support vector machine, and decision tree (DT) etc. which require training. The percentage error in fault location is within 1 km for most of the cases. Fault location scheme has been validated using χ 2 test with 5% level of significance. Proposed scheme is a setting free method and is suitable for wide range of parameters, fault detection time is less than half cycle and relay does not show any reaching mal‐operation so it is reliable, accurate and secure.

17 August 2017
Verified
Book Chapter
Closed access
PDF file
BIBhupendra Ingre
Bhupendra Ingre
AYAnamika Yadav
Anamika Yadav
ASAtul Kumar Soni
Atul Kumar Soni

1 February 2014 in Expert Systems with Applications
Verified
Journal Article
Closed access
HRHimanshu Rai
Himanshu Rai
AYAnamika Yadav
Anamika Yadav

6 May 2019 in IEEE Systems Journal
Verified
Journal Article
Closed access
BCBokka Krishna Chaitanya
Bokka Krishna Chaitanya
AYAnamika Yadav
Anamika Yadav
MPMohammad Pazoki
Mohammad Pazoki
The high-impedance faults (HIF) occurring on distribution lines go undetected by the conventional relays due to their low current magnitude. In addition to low current, HIFs also exhibit typical characteristic features, such as randomness, nonlinearity, etc., which are similar to the characteristics of the switching events, such as harmonic load switching. The advent of distributed generators (DG) into the distribution system, changes the current contribution through the substation, which also affects the HIF detection. This paper presents an intelligent HIF detection technique for distribution lines incorporating the DGs. Variational mode decomposition (VMD) is used to extract the input patterns. The commonly used empirical mode decomposition has limitation of modal aliasing that is overcome by VMD. VMD decomposes the signal into different modes that are further converted to singular values so as to obtain the analytic signal. These are finally used as an input to an efficient classifier known as the support vector machine, to create an intelligent classifier. The proposed methodology is verified on a modified IEEE 13-bus feeder for various events considering the changes in DG parameters and also the noise levels.