Michael R. Schock

Michael R. Schock

Auto-generated profile, based on publicly available information

Michael R. Schock


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2008 in Environmental Science & Technology
Verified
Journal Article
Closed access
MSMichael R. Schock
Michael R. Schock
RHRobert N. Hyland
Robert N. Hyland
MWMeghan M. Welch
Meghan M. Welch

16 December 2020 in Environment International
Verified
Journal Article
Open access
STSimoni Triantafyllidou
Simoni Triantafyllidou
JBJonathan Burkhardt
Jonathan Burkhardt
JTJennifer Tully
Jennifer Tully
KCKelly Cahalan
Kelly Cahalan
MDMichael DeSantis
Michael DeSantis
MSMichael Schock
Michael Schock
Lead (Pb) in drinking water has re-emerged as a modern public health threat which can vary widely in space and in time (i.e., between homes, within homes and even at the same tap over time). Spatial and temporal water Pb variability in buildings is the combined result of water chemistry, hydraulics, Pb plumbing materials and water use patterns. This makes it challenging to obtain meaningful water Pb data with which to estimate potential exposure to residents. The objectives of this review paper are to describe the root causes of intrinsic Pb variability in drinking water, which in turn impacts the numerous existing water sampling protocols for Pb. Such knowledge can assist the public health community, the drinking water industry, and other interested groups to interpret/compare existing drinking water Pb data, develop appropriate sampling protocols to answer specific questions relating to Pb in water, and understand potential exposure to Pb-contaminated water. Overall, review of the literature indicated that drinking water sampling for Pb assessment can serve many purposes. Regulatory compliance sampling protocols are useful in assessing community-wide compliance with a water Pb regulatory standard by typically employing practical single samples. More complex multi-sample protocols are useful for comprehensive Pb plumbing source determination (e.g., Pb service line, Pb brass faucet, Pb solder joint) or Pb form identification (i.e., particulate Pb release) in buildings. Exposure assessment sampling can employ cumulative water samples that directly capture an approximate average water Pb concentration over a prolonged period of normal household water use. Exposure assessment may conceivably also employ frequent random single samples, but this approach warrants further investigation. Each protocol has a specific use answering one or more questions relevant to Pb in water. In order to establish statistical correlations to blood Pb measurements or to predict blood Pb levels from existing datasets, the suitability of available drinking water Pb datasets in representing water Pb exposure needs to be understood and the uncertainties need to be characterized.

22 October 2020 in Environmental Science & Technology
Verified
Journal Article
Closed access
DLDarren A. Lytle
Darren A. Lytle
MSMichael R. Schock
Michael R. Schock
CFCasey Formal
Casey Formal
CBChristina Bennett-Stamper
Christina Bennett-Stamper
SHStephen Harmon
Stephen Harmon
MPMaily Pham
Maily Pham

4 March 2019 in AWWA Water Science
Verified
Journal Article
Open access
PDF file
JTJennifer Tully
Jennifer Tully
MDMichael K. DeSantis
Michael K. DeSantis
MSMichael R. Schock
Michael R. Schock
The conventional wisdom of lead‐scale solubility has been built over the years by geochemical solubility models, experimental studies, and field sampling using multiple protocols. Rarely have the mineral phases from scales formed in real‐world drinking water lead service lines (LSLs) been compared with theoretical predictions. In this study, model predictions are compared with LSL scales from 22 drinking water distribution systems. The results show that only 9 of the 22 systems had LSL scales that followed model predictions. The remaining systems had unpredictable scales, some with unknown lead release characteristics, demonstrating that predicting scale formation and lead release solely by models cannot be relied on in all cases to protect human health. Therefore, for many systems with LSLs, pilot studies with existing LSL scales will be necessary to evaluate and optimize corrosion control, and correspondingly, appropriate residential water sampling will be needed to demonstrate consistent and optimal system corrosion control.

1 November 2017 in Journal AWWA
Verified
Journal Article
Closed access
PDF file
LWLauren W. Wasserstrom
Lauren W. Wasserstrom
SMStephanie A. Miller
Stephanie A. Miller
STSimoni Triantafyllidou
Simoni Triantafyllidou
MDMichael K. Desantis
Michael K. Desantis
MSMichael R. Schock
Michael R. Schock
US corrosion control practice often assumes that the orthophosphate component of blended phosphate corrosion inhibitors causes the formation of low‐solubility lead–orthophosphate solids that control lead release into drinking water. This study identified the solids that formed on the interior surface of a lead service line and a galvanized steel pipe excavated from a system using a proprietary blended phosphate chemical. The scale was analyzed by X‐ray diffraction, X‐ray fluorescence, and scanning electron microscopy/energy dispersive spectroscopy. Instead of crystalline lead–orthophosphate solids, a porous amorphous layer rich in aluminum, calcium, phosphorus, and lead was observed at the lead pipe scale–water interface. Thus, the mechanism inhibiting lead release into the water was not a thermodynamically predictable passivating lead–orthophosphate scale, but rather an amorphous barrier deposit that was possibly vulnerable to disturbances. Galvanized pipe scales showed relatively crystalline iron and zinc compounds, with additional surface deposition of aluminum, phosphorus, calcium, and lead.

16 April 2019 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Open access
VBValerie Bosscher
Valerie Bosscher
DLDarren A. Lytle
Darren A. Lytle
MSMichael R. Schock
Michael R. Schock
APAndrea Porter
Andrea Porter
MTMiguel Del Toral
Miguel Del Toral
A field study was conducted to test the effectiveness of faucet-mounted point of use (POU) water filters for removing high concentrations of lead in drinking water from premise plumbing sources and lead service lines (LSL). These filters were concurrently certified for total lead removal under NSF/ANSI Standard 53 (NSF/ANSI-53) and for fine particulate (Class I) reduction under NSF/ANSI Standard 42 (NSF/ANSI-42). In 2016, filtered and unfiltered drinking water samples were collected at over 345 locations in Flint, Michigan. Over 97% of filtered water samples contained lead below 0.5 µg/L. The maximum lead concentration in filtered water was 2.9 µg/L, well below the bottled water standard. The effectiveness of the POU activated carbon block filters in reducing lead concentrations, even above the 150 µg/L NSF/ANSI-53 challenge standard, is likely related to trapping particles due to the small effective pore size of the filters, in addition to ion-exchange or sorption removal of soluble lead. Properly installed and maintained POU filters, certified under both NSF/ANSI-53 (for total lead) and NSF/ANSI-42 (for fine particulate), can protect all populations, including pregnant women and children, by reducing lead in drinking water to levels that would not result in a significant increase in overall lead exposure.