Duarte Dias

Mr. Duarte Dias

INESC TEC - Institute for Systems and Computer Engineering, Technology and Science
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
DDDuarte Dias
Duarte Dias
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Wearable Health Devices (WHDs) are increasingly helping people to better monitor their health status both at an activity/fitness level for self-health tracking and at a medical level providing more data to clinicians with a potential for earlier diagnostic and guidance of treatment. The technology revolution in the miniaturization of electronic devices is enabling to design more reliable and adaptable wearables, contributing for a world-wide change in the health monitoring approach. In this paper we review important aspects in the WHDs area, listing the state-of-the-art of wearable vital signs sensing technologies plus their system architectures and specifications. A focus on vital signs acquired by WHDs is made: first a discussion about the most important vital signs for health assessment using WHDs is presented and then for each vital sign a description is made concerning its origin and effect on heath, monitoring needs, acquisition methods and WHDs and recent scientific developments on the area (electrocardiogram, heart rate, blood pressure, respiration rate, blood oxygen saturation, blood glucose, skin perspiration, capnography, body temperature, motion evaluation, cardiac implantable devices and ambient parameters). A general WHDs system architecture is presented based on the state-of-the-art. After a global review of WHDs, we zoom in into cardiovascular WHDs, analysing commercial devices and their applicability versus quality, extending this subject to smart t-shirts for medical purposes. Furthermore we present a resumed evolution of these devices based on the prototypes developed along the years. Finally we discuss likely market trends and future challenges for the emerging WHDs area.

31 October 2018 in Clinical Practice & Epidemiology in Mental Health
Verified
Journal Article
Open access
PDF file
SRSusana Rodrigues
Susana Rodrigues
JPJoana S. Paiva
Joana S. Paiva
DDDuarte Dias
Duarte Dias
GPGonçalo Pimentel
Gonçalo Pimentel
Mariana KaiselerMariana Kaiseler
Mariana Kaiseler
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Stress is a complex process with an impact on health and performance. The use of wearable sensor-based monitoring systems offers interesting opportunities for advanced health care solutions for stress analysis. Considering the stressful nature of firefighting and its importance for the community's safety, this study was conducted for firefighters. A biomonitoring platform was designed, integrating different biomedical systems to enable the acquisition of real time Electrocardiogram (ECG), computation of linear Heart Rate Variability (HRV) features and collection of perceived stress levels. This platform was tested using an experimental protocol, designed to understand the effect of stress on firefighter's cognitive performance, and whether this effect is related to the autonomic response to stress. The Trier Social Stress Test (TSST) was used as a testing platform along with a 2-Choice Reaction Time Task. Linear HRV features from the participants were acquired using an wearable ECG. Self-reports were used to assess perceived stress levels. The TSST produced significant changes in some HRV parameters (AVNN, SDNN and LF/HF) and subjective measures of stress, which recovered after the stress task. Although these short-term changes in HRV showed a tendency to normalize, an impairment on cognitive performance was found after performing the stress event. Current findings suggested that stress compromised cognitive performance and caused a measurable change in autonomic balance. Our wearable biomonitoring platform proved to be a useful tool for stress assessment and quantification. Future studies will implement this biomonitoring platform for the analysis of stress in ecological settings.

18 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJoana S. Paiva
Joana S. Paiva
DDDuarte Dias
Duarte Dias
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
In recent years, safer and more reliable biometric methods have been developed. Apart from the need for enhanced security, the media and entertainment sectors have also been applying biometrics in the emerging market of user-adaptable objects/systems to make these systems more user-friendly. However, the complexity of some state-of-the-art biometric systems (e.g., iris recognition) or their high false rejection rate (e.g., fingerprint recognition) is neither compatible with the simple hardware architecture required by reduced-size devices nor the new trend of implementing smart objects within the dynamic market of the Internet of Things (IoT). It was recently shown that an individual can be recognized by extracting features from their electrocardiogram (ECG). However, most current ECG-based biometric algorithms are computationally demanding and/or rely on relatively large (several seconds) ECG samples, which are incompatible with the aforementioned application fields. Here, we present a computationally low-cost method (patent pending), including simple mathematical operations, for identifying a person using only three ECG morphology-based characteristics from a single heartbeat. The algorithm was trained/tested using ECG signals of different duration from the Physionet database on more than 60 different training/test datasets. The proposed method achieved maximal averaged accuracy of 97.450% in distinguishing each subject from a ten-subject set and false acceptance and rejection rates (FAR and FRR) of 5.710±1.900% and 3.440±1.980%, respectively, placing Beat-ID in a very competitive position in terms of the FRR/FAR among state-of-the-art methods. Furthermore, the proposed method can identify a person using an average of 1.020 heartbeats. It therefore has FRR/FAR behavior similar to obtaining a fingerprint, yet it is simpler and requires less expensive hardware. This method targets low-computational/energy-cost scenarios, such as tiny wearable devices (e.g., a smart object that automatically adapts its configuration to the user). A hardware proof-of-concept implementation is presented as an annex to this paper.

SRSusana Rodrigues
Susana Rodrigues
JPJoana S. Paiva
Joana S. Paiva
DDDuarte Dias
Duarte Dias
MAMarta Aleixo
Marta Aleixo
RFRui Manuel Filipe
Rui Manuel Filipe
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Stress can impact multiple psychological and physiological human domains. In order to better understand the effect of stress on cognitive performance, and whether this effect is related to an autonomic response to stress, the Trier Social Stress Test (TSST) was used as a testing platform along with a 2-Choice Reaction Time Task. When considering the nature and importance of Air Traffic Controllers (ATCs) work and the fact that they are subjected to high levels of stress, this study was conducted with a sample of ATCs (n = 11). Linear Heart Rate Variability (HRV) features were extracted from ATCs electrocardiogram (ECG) acquired using a medical-grade wearable ECG device (Vital Jacket® (1-Lead, Biodevices S.A, Matosinhos, Portugal)). Visual Analogue Scales (VAS) were also used to measure perceived stress. TSST produced statistically significant changes in some HRV parameters (Average of normal-to-normal intervals (AVNN), Standard Deviation of all NN (SDNN), root mean square of differences between successive rhythm-to-rhythm (RR) intervals (RMSSD), pNN20, and LF/HF) and subjective measures of stress, which recovered after the stress task. Although these short-term changes in HRV showed a tendency to normalize, an impairment on cognitive performance was evident. Despite that participant’s reaction times were lower, the accuracy significantly decreased, presenting more errors after performing the acute stress event. Results can also point to the importance of the development of quantified occupational health (qOHealth) devices to allow for the monitoring of stress responses.

11 December 2018 in PeerJ
Verified
Journal Article
Open access
PDF file
SRSusana Rodrigues
Susana Rodrigues
JPJoana S. Paiva
Joana S. Paiva
DDDuarte Dias
Duarte Dias
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Background Stress at work has been broadly acknowledged as a worldwide problem and has been the focus of concern for many researchers. Firefighting, in particular, is frequently reported as a highly stressful occupation. In order to investigate firefighters’ occupational health in terms of stress events, perceptions, symptoms, and physiological reactions under real-world conditions, an ambulatory assessment protocol was developed. Methods Seventeen firefighters’ cardiac signal was continuously monitored during an average of three shifts within a working week with medical clinically certified equipment (VitalJacket®), which allows for continuous electrocardiogram (ECG) and actigraphy measurement. Psychological data were collected with a software application running on smartphones, collecting potential stressful events, stress symptoms, and stress appraisal. Results A total of 450.56 h of medical-quality ECG were collected, and heart rate variability (HRV) analysis was performed. Findings suggest that although ‘fire’ situations are more common, ‘accidents’ are more stressful. Additionally, firefighters showed high levels of physiological stress (based on AVNN and LF/HF HRV metrics) when compared to normative healthy population values that may not be diagnosed using merely self-reports. Discussion The proposed ambulatory study seems to be useful for the monitoring of stress levels and its potential impact on health of first responders. Additionally, it could also be an important tool for the design and implementation of efficient interventions and informed management resolutions in real time. Potential applications of this research include the development of quantified occupational health (qOHealth) devices for real life monitoring of emergency personnel stress reactions.

7 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Elodie LopesElodie Lopes
Elodie Lopes
MVMaria do Carmo Vilas-Boas
Maria do Carmo Vilas-Boas
DDDuarte Dias
Duarte Dias
MRMaria José Rosas
Maria José Rosas
RVRui Vaz
Rui Vaz
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Deep brain stimulation (DBS) surgery is the gold standard therapeutic intervention in Parkinson’s disease (PD) with motor complications, notwithstanding drug therapy. In the intraoperative evaluation of DBS’s efficacy, neurologists impose a passive wrist flexion movement and qualitatively describe the perceived decrease in rigidity under different stimulation parameters and electrode positions. To tackle this subjectivity, we designed a wearable device to quantitatively evaluate the wrist rigidity changes during the neurosurgery procedure, supporting physicians in decision-making when setting the stimulation parameters and reducing surgery time. This system comprises a gyroscope sensor embedded in a textile band for patient’s hand, communicating to a smartphone via Bluetooth and has been evaluated on three datasets, showing an average accuracy of 80%. In this work, we present a system that has seen four iterations since 2015, improving on accuracy, usability and reliability. We aim to review the work done so far, outlining the iHandU system evolution, as well as the main challenges, lessons learned, and future steps to improve it. We also introduce the last version (iHandU 4.0), currently used in DBS surgeries at São João Hospital in Portugal.