Jakub Kostelecky

Dr. Jakub Kostelecky

Research Institute of Geodesy, Topography and Cartography, Geodetic Observatory Pecny
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2013 in Metrologia
Verified
Journal Article
Closed access
Olivier FrancisOlivier Francis
Olivier Francis
HBHenri Baumann
Henri Baumann
TVTomas Volarik
Tomas Volarik
CRChristian Rothleitner
Christian Rothleitner
GKGilbert Klein
Gilbert Klein
RBRyan Billson
Ryan Billson


20 April 2017 in GPS Solutions
Verified
Journal Article
Closed access
PDF file
PVPavel Vaclavovic
Pavel Vaclavovic
JDJan Douša
Jan Douša
MEMichal Elias
Michal Elias
JKJakub Kostelecky
Jakub Kostelecky

1 January 2021 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
ELEpameinondas Lyros
Epameinondas Lyros
JKJakub Kostelecky
Jakub Kostelecky
VPVladimir Plicka
Vladimir Plicka
FVFiller Vratislav
Filler Vratislav
Efthimios SokosEfthimios Sokos
Efthimios Sokos
KNKonstantinos Nikolakopoulos
Konstantinos Nikolakopoulos
Aitolo-Akarnania prefecture, western Greece, is an area with strong earthquakes and large active fault systems. The most prominent are the Katouna sinistral strike slip fault and the Trichonis Lake normal fault system. Their proximity to large cities, and the lack of detailed information on their seismogenic potential, calls for multiparametric research. Since 2013, the area's crustal deformation has been monitored by a dense GNSS Network (PPGNet), consisting of five stations, equipped with Leica and Septentrio receivers. The objective of this network is to define the rate of deformation across these two main fault systems. Data is recorded using two sampling frequencies, 1 Hz and 10Hz, producing hourly and daily files. Daily data is processed using Bernese GNSS Processing Software using final orbits of International GNSS Service. Double-difference solution is computed using phase measurements from the PPGNet network complemented by four stations from Athens' National Observatory GNSS network and six stations from METRICA network. First results show a NNE movement at PVOG station of 12 mm/y and a similar movement at RETS station of about 9 mm/y. This means that the Trichonis Lake normal fault system, located between these two stations, depicts a slip rate of 3 mm/y. KTCH and RGNI stations move eastwards at a velocity of about 5 mm/y due to the Katouna-Stamna fault system. Data from PPGNet has provided important results on crustal deformation in the area, i.e. slip rates have been attributed to specific fault systems. The comparison and links of these data with broader geodynamic models is now possible and we expect, in a later phase that will provide a more detailed image of the associated seismic hazard for Aitolo-Akarnania. Doi: 10.28991/cej-2021-03091633 Full Text: PDF

16 October 2024 in Journal of Applied Geodesy
Verified
Journal Article
Closed access
VFVratislav Filler
Vratislav Filler
JKJakub Kostelecky
Jakub Kostelecky
Networked Real-Time Kinematic (NRTK) is the most widely used GNSS (Global Navigation Satellite Systems) positioning technique in surveying practice due to its speed, operability and sufficient accuracy. Positioning using NRTK methods in the European Terrestrial Reference System ETRS89 obligatory coordinate system is tied to the positioning of reference stations of the RTK network. Monitoring of GNSS reference stations provides both the determination of the position of individual stations in the obligatory coordinate system and the monitoring of daily position deviations of individual stations. The application to four networks of GNSS reference stations in the Czech Republic has demonstrated the accuracy of the positioning of stations from the daily solution at the level of 1.2 mm in the horizontal components and 3.8 mm in the vertical component. This accuracy is quite suitable for NRTK methods that determine position with centimetre accuracy. At the same time, it allows to detect the behaviour of time series of coordinates of individual stations – sudden jumps, linear and periodic trends. The accuracy achieved also allows tracking geokinematic movements.

19 March 2026 in GPS Solutions
Verified
Journal Article
Open access
PDF file
OVOndrej Vana
Ondrej Vana
JKJakub Kostelecky
Jakub Kostelecky
The RTK (Real-Time Kinematic) method is an effective method for fast and sufficiently accurate positioning using Global Navigation Satellite System (GNSS) technology. The combination of a GNSS receiver with other sensors brings expanded use. In this article, we test a laser RTK method which is the unusual combination of a GNSS receiver with an Inertial Measurement Unit (IMU) and a laser rangefinder, as implemented in the new HiTarget V6001 receiver. We compare the accuracy of determining the spatial position of hard-to-reach points when targeting buildings and other objects. The reference was the determination of the position using the spatial polar method with a precise total station. Its position was determined as a free station relative to three points determined by the GNSS RTK method. The tests showed that the HiTarget V6001 receiver determines the spatial position with an accuracy corresponding to the specifications. Only 2 points out of a total of 35 were determined with an error exceeding the expected accuracy. A comparison of the results revealed a systematic vertical bias of 17 mm. The HiTarget V6001 receiver is fast and economical for determining position or staking out dozens of points. Positioning is easier and faster than with a combination of GNSS receiver and a total station. The spatial position accuracy of 50 mm on average in the horizontal components and 87 mm in the vertical component (for an average slant distance of 18 m) is sufficient for most mapping and staking-out work. More than 80% of the accuracy is attributable to the polar method implemented using a laser rangefinder and IMU. The accuracy pf RTK positioning accounts for only about 20% of the total accuracy.