Marco Caetano

Mr. Marco Caetano

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2023 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
AGAna Monteiro Grilo
Ana Monteiro Grilo
BABárbara Almeida
Bárbara Almeida
CRCarolina Rodrigues
Carolina Rodrigues
AGAna Isabel Gomes
Ana Isabel Gomes
Marco CaetanoMarco Caetano
Marco Caetano
To understand the impact of radiotherapy educational sessions with virtual reality on oncologic adult patients' psychological and cognitive outcomes related to the treatment experience. This review was performed according to the Preferred Reporting Items for Systematic Reviews guidelines. A systematic electronic search in three databases, MEDLINE, Scopus, and Web of Science, was conducted in December 2021 to find interventional studies with adult patients undergoing external radiotherapy who received an educational session with virtual reality before or during the treatment. The studies that provided qualitative or quantitative information about the impact of educational sessions on patients' psychological and cognitive dimensions related to RT experience were retained for analysis. Of the 25 records found, eight articles about seven studies were analysed that involved 376 patients with different oncological pathologies. Most studies evaluated knowledge and treatment-related anxiety, mainly through self-reported questionnaires. The analysis showed a significant improvement in patients' knowledge and comprehension of radiotherapy treatment. Anxiety levels also decreased with virtual reality educational sessions and throughout the treatment in almost all the studies, although with less homogeneous results. Virtual reality methods in standard educational sessions can enhance cancer patients' preparation for radiation therapy by increasing their understanding of treatment and reducing anxiety.

16 April 2025 in JMIR Cancer
Verified
Journal Article
Open access
AGAna Grilo
Ana Grilo
CMCatarina Marques
Catarina Marques
MCMaria Corte-Real
Maria Corte-Real
Elisabete CarolinoElisabete Carolino
Elisabete Carolino
Marco CaetanoMarco Caetano
Marco Caetano
Background: Patients frequently resort to the internet to access information about cancer. However, these websites often lack content accuracy and readability. Recently, ChatGPT, an artificial intelligence–powered chatbot, has signified a potential paradigm shift in how patients with cancer can access vast amounts of medical information, including insights into radiotherapy. However, the quality of the information provided by ChatGPT remains unclear. This is particularly significant given the general public’s limited knowledge of this treatment and concerns about its possible side effects. Furthermore, evaluating the quality of responses is crucial, as misinformation can foster a false sense of knowledge and security, lead to noncompliance, and result in delays in receiving appropriate treatment. Objective: This study aims to evaluate the quality and reliability of ChatGPT’s responses to common patient queries about radiotherapy, comparing the performance of ChatGPT’s two versions: GPT-3.5 and GPT-4. Methods: We selected 40 commonly asked radiotherapy questions and entered the queries in both versions of ChatGPT. Response quality and reliability were evaluated by 16 radiotherapy experts using the General Quality Score (GQS), a 5-point Likert scale, with the median GQS determined based on the experts’ ratings. Consistency and similarity of responses were assessed using the cosine similarity score, which ranges from 0 (complete dissimilarity) to 1 (complete similarity). Readability was analyzed using the Flesch Reading Ease Score, ranging from 0 to 100, and the Flesch-Kincaid Grade Level, reflecting the average number of years of education required for comprehension. Statistical analyses were performed using the Mann-Whitney test and effect size, with results deemed significant at a 5% level (P=.05). To assess agreement between experts, Krippendorff α and Fleiss κ were used. Results: GPT-4 demonstrated superior performance, with a higher GQS and a lower number of scores of 1 and 2, compared to GPT-3.5. The Mann-Whitney test revealed statistically significant differences in some questions, with GPT-4 generally receiving higher ratings. The median (IQR) cosine similarity score indicated substantial similarity (0.81, IQR 0.05) and consistency in the responses of both versions (GPT-3.5: 0.85, IQR 0.04; GPT-4: 0.83, IQR 0.04). Readability scores for both versions were considered college level, with GPT-4 scoring slightly better in the Flesch Reading Ease Score (34.61) and Flesch-Kincaid Grade Level (12.32) compared to GPT-3.5 (32.98 and 13.32, respectively). Responses by both versions were deemed challenging for the general public. Conclusions: Both GPT-3.5 and GPT-4 demonstrated having the capability to address radiotherapy concepts, with GPT-4 showing superior performance. However, both models present readability challenges for the general population. Although ChatGPT demonstrates potential as a valuable resource for addressing common patient queries related to radiotherapy, it is imperative to acknowledge its limitations, including the risks of misinformation and readability issues. In addition, its implementation should be supported by strategies to enhance accessibility and readability.

24 December 2020 in Journal of Nuclear Medicine Technology
Verified
Journal Article
Open access
PDF file
PLPaula Susana Lopes
Paula Susana Lopes
SFSara Ferreira
Sara Ferreira
Marco CaetanoMarco Caetano
Marco Caetano
Introduction: PET/CT combines the molecular with the anatomical level which, with the administration of a hypoxia-sensitive radiopharmaceutical, allows the evaluation of tissue oxygenation. Materials and Methods: The work consists of a systematic literature review, including electronic addresses, books and articles dated from July 1997 to December 2019. The aim of this work is to identify the best suited PET radiopharmaceuticals for the detection of cell hypoxia and recognize the benefits for treatment planning with IMRT/VMAT techniques. Results: Hypoxia affects the likelihood cure of head and neck tumors, thereby reducing the success rate. Radiopharmaceuticals such as 18F-FMISO, 18F-FETNIM and 18F-HX4 allow the delineation of hypoxic subvolumes within the target volume to optimize IMRT/VMAT treatment. Discussion: The identification of hypoxia areas with PET/CT imaging and subsequent treatment with IMRT/VMAT allows a possible radiation dose escalation in radioresistant subvolumes. Conclusion: There is a decrease in relapses and an increased likelihood of disease-free survival.

20 December 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Marco CaetanoMarco Caetano
Marco Caetano
João GregorioJoão Gregorio
João Gregorio
Marília Silva PauloMarília Silva Paulo
Marília Silva Paulo
To identify the most used dosimeters for monitoring ultraviolet radiation (UVR) and analyze their reliability and cost for individual UV exposure monitoring, this study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. An extensive search of the PubMed, Scopus, and Web of Science databases, covering 2005–2023, was conducted, including examining reference lists of retrieved studies. Of the 1202 records, 52 were eligible for analysis. Three types of dosimeters were identified: photosensitive, photochromic, and electronic dosimeters. Photosensitive dosimeters were utilized for 1236 samples across the studies, while photochromic dosimeters were employed for 360 samples. Electronic dosimeters, with a sample size of 3632, were the most extensively studied. This study highlights the variety of resources available for UVR assessment and the significance of specific dosimeter types in this field. Although few studies have explored the costs associated with dosimeter use, electronic dosimeters are the most cost-effective for radiation monitoring and provide the highest accuracy for measuring UVR exposure. Electronic dosimeters, known for real-time data and high precision, are reliable but costly, being approximately 16.5 times more expensive than photosensitive dosimeters and 160 times more expensive than photochromic dosimeters. Photosensitive dosimeters suit large-scale personal use, and photochromic sensors such as polysulphone dosimeters are also reliable. Additional costs for data analysis software, laboratory equipment, or external analysis services may be incurred, especially for advanced research-grade sensors.

20 July 2022 in ROENTGEN-Revista Científica das Técnicas Radiológicas
Verified
Journal Article
Open access
PDF file
JMJoão Marques
João Marques
Marco CaetanoMarco Caetano
Marco Caetano
JSJoep Stroom
Joep Stroom
CGCarlo Greco
Carlo Greco
Introdução: Os sistemas de planeamento utilizam a informação das densidades eletrónicas, necessárias para o cálculo de dose provenientes da TC. Uma tendência recente é o uso da RM como única modalidade, usando as imagens de RM para criar uma TC sintética. Um fluxo de trabalho no qual todas as etapas pré-tratamento são realizadas na RM é favorável. O objetivo do estudo é validar a técnica MR-Only como imagem de referência na verificação do posicionamento em Radioterapia. Metodologia: Foram incluídos 13 doentes com tumor cerebral e 15 doentes com tumor retal, seguidos no Serviço de Radioterapia do Centro Clínico Champalimaud, de outubro de 2019 a junho de 2020. Com base no registo automático de 80 CBCT comparou-se os desvios entre as imagens da TC de planeamento e da TC sintética (MR-Only). Resultados: No registo das imagens do reto, a variação que se obteve foi inferior a 1,4mm longitudinal, 1mm lateral e vertical. A variação nas translações foi de -0,2±0,3mm lateral, -0,3±0,4mm vertical e de -0,4±0,7mm longitudinal. As rotações foram inferiores a 0,4º, sendo a variação verificada 0,0±0,2º pitch, 0,0±0,1º yaw e de 0,0±0,1º roll. No cérebro foi inferior a 1,3mm longitudinal, a 0,6mm vertical e a 0,4mm lateral. A variação verificada foi de -0,2±0,2mm lateral, -0,3±0,2mm vertical e de -0,4±0,5mm longitudinal. Nas rotações, obteve-se uma rotação máxima de 0,3º, sendo a variação verificada -0,2±0,1º pitch, 0,1±0,1º yaw e de 0,0±0,1º roll. Conclusão: Foi validado o registo da imagem da TC sintética com a imagem de verificação CBCT. Os desvios encontrados nos registos entre a TC de planeamento e a TC sintética da RM sugerem que é justificado o uso da técnica MR-Only como imagem de referência.

1 June 2022
Verified
Journal Article
Closed access
MDMónica Duarte
Mónica Duarte
VRVanessa Rodrigues
Vanessa Rodrigues
Marco CaetanoMarco Caetano
Marco Caetano
PFPaulo Fernandes
Paulo Fernandes
BBBartos Bak
Bartos Bak