Abhilasha Shrestha

Abhilasha Shrestha

Auto-generated profile, based on publicly available information

Abhilasha Shrestha


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2017 in Environmental Health
Verified
Journal Article
Open access
PDF file
SDSamuel Dorevitch
Samuel Dorevitch
ASAbhilasha Shrestha
Abhilasha Shrestha
SDStephanie DeFlorio-Barker
Stephanie DeFlorio-Barker
CBCathy Breitenbach
Cathy Breitenbach
IHIra Heimler
Ira Heimler
The United States Environmental Protection Agency has established methods for testing beach water using the rapid quantitative polymerase chain reaction (qPCR) method, as well as “beach action values” so that the results of such testing can be used to make same-day beach management decisions. Despite its numerous advantages over culture-based monitoring approaches, qPCR monitoring has yet to become widely used in the US or elsewhere. Considering qPCR results obtained on a given day as the best available measure of that day’s water quality, we evaluated the frequency of correct vs. incorrect beach management decisions that are driven by culture testing. Beaches in Chicago, USA, were monitored using E. coli culture and enterococci qPCR methods over 894 beach-days in the summers of 2015 and 2016. Agreement in beach management using the two methods, after taking into account agreement due to chance, was summarized using Cohen’s kappa statistic. No meaningful agreement (beyond that expected by chance) was observed between beach management actions driven by the two pieces of information available to beach managers on a given day: enterococci qPCR results ofsamples collected that morning and E. coli culture results of samples collected the previous day. The E. coli culture beach action value was exceeded 3.4 times more frequently than the enterococci qPCR beach action value (22.6 vs. 6.6% of beach-days). The largest evaluation of qPCR-based beach monitoring to date provides little scientific rationale for continued E. coli culture testing of beach water in our setting. The observation that the E. coli culture beach action value was exceeded three times as frequently as the enterococci qPCR beach action value suggests that, although the beach action values for bacteria using different measurement methods are thought to provide comparable information about health risk, this does not appear to be the case in all settings.

6 June 2020 in Water Research
Verified
Journal Article
Closed access
ASAbhilasha Shrestha
Abhilasha Shrestha
CKCatherine A. Kelty
Catherine A. Kelty
MSMano Sivaganesan
Mano Sivaganesan
OSOrin C. Shanks
Orin C. Shanks
SDSamuel Dorevitch
Samuel Dorevitch

1 June 2019 in Water Research
Verified
Journal Article
Open access
ASAbhilasha Shrestha
Abhilasha Shrestha
SDSamuel Dorevitch
Samuel Dorevitch
Most Great Lakes communities rely on culture-based E. coli methods for monitoring fecal indicator bacteria (FIB) at recreational beaches. These cultivation methods require 18 or more hours to generate results. As a consequence, public notifications about beach action value (BAV) exceedance are based on prior-day water quality. Rapid qPCR monitoring of bacteria in beach water solves the 24-h delay problem, though the USEPA-approved qPCR method targets enterococci bacteria, while Great Lakes communities are familiar with E. coli monitoring. For an E. coli qPCR method to be useful for water quality management, it is important to systematically characterize method performance, and establish BAVs for public notification purposes. In this study, we 1) evaluated a draft USEPA E. coli qPCR method, 2) compared E. coli qPCR measurements with two established FIB (E. coli culture and enterococci qPCR) results, and explored potential strategies to establish E. coli qPCR BAV criteria in the absence of an epidemiological study. Based on analyses of 288 water samples collected from eight of Chicago's Lake Michigan beaches, the E. coli qPCR method demonstrates acceptable performance characteristics. The method is prone to low level DNA contamination, possibly originating from assay reagents derived from E. coli bacteria. Both E. coli and enterococci BAVs were exceeded in approximately 18% of the samples. E. coli qPCR values were correlated with both E. coli culture (r = 0.83; p < 0.0001) and enterococci qPCR (r = 0.67; p < 0.0001) values. The approach recommended by the USEPA in its Technical Support Material (TSM) was used to generate candidate E. coli qPCR BAVs, as was receiver operating characteristic (ROC) analysis. Potential BAV thresholds differed substantially, ranging from 200.9 calibrator cell equivalents (CCE)/100 mL (ROC analysis, enterococci qPCR BAV as the reference) to 1000 CCE/100 mL (TSM analysis, enterococci qPCR BAV as the reference). Because we found that different approaches to establishing potential BAVs generate quite different values, guidance from USEPA about approaches to defining comparable BAVs would be useful.

1 July 2020 in Journal of Microbiological Methods
Verified
Journal Article
Open access
ASAbhilasha Shrestha
Abhilasha Shrestha
SDSamuel Dorevitch
Samuel Dorevitch
In 2012 the US Environmental Protection Agency published new Recreational Water Quality Criteria, which for the first time, included criteria values and beach action values for quantitative polymerase chain reaction (qPCR) measurements or estimates of enterococci. The qPCR method makes it possible to generate indicator bacterial test results within several hours, and notify the public immediately, rather than the following day, which would be the case if culture methods were used. The BEach ACtion and Closing Online Notification (BEACON) data demonstrates that less than 1% of microbial beach water results for the years 2014-2018 were generated using qPCR. In order to assist jurisdictions considering the implementation of same-day beach water monitoring and notification, we describe a qPCR-based beach monitoring program in which a central laboratory tests water samples from up to 20 beaches per day, seven days per week, and reports the results to the public by noon. The transition from a culture-based monitoring program to a qPCR program, staffing, management, communications needs, fixed costs, and variable costs of the program are described. USEPA funding to support state and local governments implementing qPCR programs may be needed if the benefits of same-day notification regarding elevated health risks are to be realized.

SDSamuel Dorevitch
Samuel Dorevitch
KAKendall Anderson
Kendall Anderson
ASAbhilasha Shrestha
Abhilasha Shrestha
DFDorothy Wright Foulkes
Dorothy Wright Foulkes
AOAloyce Odhiambo
Aloyce Odhiambo
IHIra Heimler
Ira Heimler
Ozonation is widely used in high-income countries for water disinfection in centralized treatment facilities. New microplasma technology has reduced the energy requirements for ozone generation dramatically, such that a 15-watt solar panel is sufficient to produce small quantities of ozone. This technology has not been used previously for point-of-use drinking water treatment. We conducted a series of assessments of this technology, both in the laboratory and in homes of residents of a village in western Kenya, to estimate system efficacy and to determine if the solar-powered point-of-use water ozonation system appears safe and acceptable to end-users. In the laboratory, two hours of point-of-use ozonation reduced E. coli in 120 L of wastewater by a mean (standard deviation) of 2.3 (0.84) log-orders of magnitude and F+ coliphage by 1.54 (0.72). Based on laboratory efficacy, 10 families in Western Kenya used the system to treat 20 L of household stored water for two hours on a daily basis for eight weeks. Household stored water E. coli concentrations of >1000 most probable number (MPN)/100 mL were reduced by 1.56 (0.96) log removal value (LRV). No participants experienced symptoms of respiratory or mucous membrane irritation. Focus group research indicated that families who used the system for eight weeks had very favorable perceptions of the system, in part because it allowed them to charge mobile phones. Drinking water ozonation using microplasma technology may be a sustainable point-of-use treatment method, although system optimization and evaluations in other settings would be needed.