Somchat Jiriwibhakorn

Dr. Somchat Jiriwibhakorn

EE Department, School of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Krung Thep Maha Nakhon, Thailand
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2023 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
SKShazia Kanwal
Shazia Kanwal
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
An overview of the many methods used for fault detection, classification and location in the power system, particularly in transmission lines, is provided in this review, it also includes an experimental result of adaptive neuro-fuzzy inference system -based fault detection , fault classification and fault location. Being in operation outdoor environment, transmission lines are more vulnerable to various faults which may lead to system collapse in severe cases. Therefore, to ensure the reliable and safe operation of power system it is imperative to critically monitor the faults in transmission lines. In this regard, researchers around the globe have developed several techniques and constantly putting efforts to further improve the protection efficacy. The brief yet thorough analysis and comparison of the artificial intelligence-based techniques, hybrid methodologies and most recent approaches in the context of power system faults have been discussed and presented. In addition, the research work and the experimental results of an adaptive neuro-fuzzy inference system-based techniques have also been discussed for IEEE-9 bus system. The mean square error for testing data of ANFIS-based fault detection, classification, is zero and for fault location Mean square error is 5.32km. This piece of work could be helpful in the development of a comprehensive understanding of various artificial intelligence-based techniques within the realm of fault detection, classification and localization in transmission lines.

3 April 2024 in IEEE Access
Verified
Journal Article
Open access
SKShazia Kanwal
Shazia Kanwal
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
Electric systems are getting more complex with time, and primitive protection methods such as traveling wave and impedance-based methods face limitations and shortcomings. This paper incorporates and presents the applications of an adaptive neuro-fuzzy inference system and compares it with a back propagation neural network, self-organizing map, and hybrid method of discrete wavelet with adaptive neuro-fuzzy inference system for fault detections, classification, and localization in transmission lines. These methods, in comparison with primitive methods, could be capable of detecting, identifying, and predicting the location of the faults more accurately. The IEEE 9-bus system is utilized to obtain data from one end of the transmission line to develop an ANFIS-based model. This system is simulated in MATLAB/Simulink for different fault cases at various locations. The three-phase voltage and current at one end of IEEE 9-bus number seven are taken for training. Three ANFIS models are developed for fault detection, classification, and localization and compared with other models. For verification of the models, mean square error, mean absolute error, and regression analysis have been computed and compared for all the models. All four techniques have performed well for fault classification, detection, and location. However, the percentage error for the ANFIS-based fault model is less compared to backpropagation, self-organizing map, and discrete wavelet transform with ANFIS. Therefore, the proposed ANFIS models can be implemented for deploying in real-time-based protection systems.

4 July 2025 in IEEE Access
Verified
Journal Article
Open access
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
SKShazia Kanwal
Shazia Kanwal
Transmission line faults present a significant threat to the stability of power systems, potentially causing widespread outages. Timely detection of these faults is essential to prevent substantial disruptions in the power supply. This paper explores a time series-based deep learning technique for fault detection and classification in the IEEE 9-bus system. Post asymmetrical fault current and voltage time series data have been used to train a convolutional neural network (CNN), representing normal and faulty conditions, with convolutional and ReLU layers. A fully connected layer is used to detect features without missing critical information of the signal, achieving MSE as zero for fault detection and 0.0149 for fault classification. This demonstrates the effectiveness of CNNs for real-time fault detection and classification in complex power grids. The robustness of the CNN model indicates its potential for deployment in practical applications, enhancing the reliability and resilience of the transmission network. Using deep learning techniques opens opportunities for further improvements in fault detection and location strategies within the power grid.

11 September 2024 in IEEE Access
Verified
Journal Article
Open access
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
KWKamolwan Wongwut
Kamolwan Wongwut
The evaluation of power demand is fundamental in the Economic Load Dispatch problem, ensuring that the generated power meets the needs of consumers reliably and efficiently in planning system operations. This paper presented two approaches using an Adaptive Neuro-Fuzzy Inference System (ANFIS) and an Artificial Neural Network (ANN) to evaluate the power demand. The modified IEEE 57-Bus system is considered the thermal units that incorporate renewables. The ANFIS and ANN are implemented using MATLAB online version R2023b. The results show that the ANN and ANFIS techniques are suitable for evaluating power demand. A comparison of both methods indicates that ANFIS is relatively superior to the ANNs techniques, considering the coefficient of determination of the ANNs and ANFIS were equal. The accuracy of its results in terms of prediction RMSE for the ANN and ANFIS of 10.147e-05 and 5.2177e-05 for the training and 14.639e-05 and 5.2177e-05 for the testing, respectively. Finally, the prediction accuracy of the ANFIS can be observed to be higher than that of the ANN, but the ANFIS takes longer to process. ANFIS is the method that can be appropriately applied to evaluate the power demand in this research. However, it could not guarantee for other research topics that ANFIS would be better than ANN for the RMSE. It depends on input and output data complexity and the training function type.

12 December 2023 in IEEE Access
Verified
Journal Article
Open access
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
An adaptive neuro-fuzzy inference system (ANFIS) is a hybrid algorithm composed of fuzzy logic and an artificial neural network. It takes advantage of fuzzy logic and artificial neural networks to solve complex problems. For power transmission, several dynamic parameters are ignored for conventional transient stability assessment due to the complexity of the equations, and due to the long computational time required. Certainly, it is very difficult to do the real-time assessment of large power systems by considering dynamic impacts in detail. In this paper, an approach is required to increase the accuracy of results. Herein, a method, namely ANFIS, was found to overcome the limitations. All significant effects of dynamics can be taken into account; not only the machine model but also the turbine governor model, automatic voltage regulator (AVR) model, and load characteristic model are carefully considered. In addition, the model used for each generator unit is varied to achieve real conditions. The ANFIS output is the critical clearing time (CCT). CCT values are very important to be correctly predicted for the stability of power systems after clearing the faults. When the faults are cleared by opening the circuit breakers within the CCT values, the power systems are still stable. If the faults are cleared after the CCT values, the systems become unstable. The modified IEEE 9-bus and IEEE 39-bus systems are applied in the implementation of this study. The locations of faults and the levels of loads (except the power system topology changes) are varied for each simulation. The results from the ANFIS application indicate that ANFIS (considering the dynamic effects of the machine models, AVR system, turbine governors, and load characteristics) can predict CCT values with high accuracy. Moreover, when ANFIS results are compared to the artificial neural network (ANN) results, which are generally used, it can be seen that ANFIS results are better and take a lower time for training and testing processes than ANN. ANFIS can be adapted, improved, and implemented in real practice.

1 July 2018
Verified
Conference Paper
Closed access
KWKhanittha Wannakam
Khanittha Wannakam
Somchat JiriwibhakornSomchat Jiriwibhakorn
Somchat Jiriwibhakorn
Wind turbine power generation planning requires production estimation. Wind power is uncertain depending on the location, wind speed and wind turbine efficiency. This paper presents a method for evaluating wind energy production using Weibull distribution and Artificial neural networks to compare the data recorded by Promthep Alternative Energy Station, Phuket, Thailand. The results show that wind energy estimation using artificial neural networks produces the most accurate results. Mean Absolute Percentage Error is used to determine the minimum error value. Minimal error of training data is 2.524% and the test data is 3.3041%.