Implantable loop recorders (ILRs) are increasingly being used for long-term cardiac monitoring in different clinical settings. The aim of this study was to investigate the real-world performance of ILRs-including the time to diagnosis- in unselected patients with different ILR indications. In this multicenter, observational study, 871 patients with an indication of pre-syncope/syncope (61.9%), unexplained palpitations (10.4%), and atrial fibrillation (AF) detection with a history of cryptogenic stroke (CS) (27.7%) underwent ILR implantation. The median follow-up was 28.8 ± 12.9 months. In the presyncope/syncope group, 167 (31%) received a diagnosis established by the device. Kaplan-Meier estimates indicated that 16.9% of patients had a diagnosis at 6 months, and the proportion increased to 22.5% at 1 year. Of 91 patients with palpitations, 20 (22%) received a diagnosis based on the device. The diagnosis established at 12.2% of patients at 6 months, and the proportion increased to 13.3% at 1 year. Among 241 patients with CS, 47 (19.5%) were diagnosed with AF. The diagnostic yield of the device was 10.4% at 6 months and 12.4% at 1 year. In all cases, oral anticoagulation was initiated. Overall, ILR diagnosis altered the therapeutic strategy in 26.1% in presyncope/syncope group, 2.2% in palpitations group, and 3.7% in CS group in addition to oral anticoagulation initiation. In this real-world patient population, ILR determines diagnosis and initiates a new therapeutic management in nearly one fourth of patients. ILR implantation is valuable in the evaluation of patients with unexplained presyncope/syncope, CS and palpitations.
Introduction: Pulsed field ablation (PFA) is a form of nonthermal energy that has been recently introduced for pulmonary vein isolation (PVI). A multi‐electrode pentaspline catheter for delivery of PFA guided by fluoroscopy has become widely available for clinical use.Methods and Results: In this study, we aimed to assess whether the addition of electroanatomical mapping (EAM) for confirmation of PVI in the acute phase can increase the efficacy of the procedure in terms of arrhythmia recurrences. A total of 51 patients with atrial fibrillation (AF) scheduled for first time PVI were included in the study. Participants were assigned to receive PVI using fluoroscopy guidance only (Fluoro‐only group: 31 patients) or additional validation with EAM (EAM group: 20 patients). Endpoints included arrhythmia recurrence and procedural characteristics. During a 11.2 ± 1.3 months follow‐up period, arrhythmia recurrences did not statistically differ between groups (16.1% vs. 20%, p .72). Procedure time was longer in the EAM group (86.5 ± 11.4 vs. 78.4 ± 9.3 min, p .008). EAM revealed 5 nonisolated PVs that were re‐ablated using the same catheter. Four patients of the cohort underwent a redo‐procedure during the follow‐up period. In all 4 cases, at least one reconnected PV was identified.Conclusion: In a cohort of patients with AF undergoing first time PVI using a pentaspline PFA catheter, PVI validation with EAM did not lead to significantly different arrhythmia recurrence rates compared to PVI without EAM. In the acute phase, the rate of nonisolated PVs was low.
Patent ductus arteriosus (PDA) continues to be a significant finding among infants, as well as adults. What is widely considered to be a problem though, in a group of patients with congenital heart disease, it is the only lifeline. We will initially study the anatomical and biochemical mechanisms affecting the PDA. The main focus of this review is on ductal-dependent congenital heart disease and biochemical and pharmacological approaches to maintaining ductus arteriosus patency, as well as surgical and interventional options for maintaining circulation. The present review aims to highlight gaps in the knowledge regarding the multifunctional role of ductus arteriosus endothelium and possibly propose a new approach to pharmacological maintenance of ductus arteriosus patency.
The Fontan operation, the final palliative step after a series of complex operations in patients with univentricular hearts, has undergone multiple modifications throughout the last decades, with the goal of finding the method which combines the optimal hemodynamic effects of the Fontan circulation with minimal long term side effects. An understanding of the operative evolution and subsequent side effects, as well as the management thereof seems imperative. Since its inception by Francis Fontan the, now obsolete, initial atriopulmonary connection has passed through several milestones into having now reached the era of total cavopulmonary connection. However, recently published results bring to light the new option of biventricular conversion which comes to challenge the management of Fontan patients as we know it. Currently, there is no consensus as to whether to continue with palliation in this challenging group of patients or proceed with heart transplantation. In this collective review, we provide a historic overview of the Fontan evolution as well as future insights, discussing the perspectives of options for patients with failing Fontan, including the latest addition of biventricular correction.
High-power short duration(HPSD) and very high-power short duration(vHPSD-90W/4s) radiofrequency(RF) technology has reduced the procedure time of pulmonary vein isolation(PVI) using RF without compromising the efficacy of the technique. The current study compares the novel technology of HPSD/vHPSD with cryoablation(CRYO) in terms of efficacy, safety and procedure time in a cohort of symptomatic patients with paroxysmal atrial fibrillation(pAF). This is a prospective non-randomized trial. Patients with pAF received either CRYO or HPSD/vHPSD RF PVI. The primary endpoint of the study was arrhythmia recurrence in 12 months follow-up period. Secondary endpoints included procedure time, fluoroscopy time and safety. 104 patients were included (45 in HPSD/vHPSD and 59 in CRYO), with comparable characteristics between groups. The follow-up was 12.4 +/- 0.5 months. There was no significant difference regarding arrhythmia recurrences during the early post-procedural period of first 3 months (8.9% recurrences in HPSD/vHPSD versus 5.1% in CRYO-p 0.463) and in the mid-term follow up of 12 months (17.8% recurrences in HPSD/vHPSD versus 10.2% in CRYO-p 0.385). Safety was excellent for both procedures. CRYO was a procedure of significantly shorter duration (64.64±8.94 min versus 75.29±18.30min, p 0.0001) at the expense of longer fluoroscopy time (HPSD/vHPSD 5.34±1.83 versus 7.89±3.70min CRYO, p 0.001). HPSD/vHPSD and CRYO in pAF were comparable regarding the arrhythmia recurrence rates in a 12 months follow-up with excellent safety. The hybrid approach of HPSD/vHPSD has accelerated RF-PVI, compared to conventional RF, but CRYO remains a procedure of significantly shorter duration at the expense of longer fluoroscopy time.
Background: Premature ventricular contractions (PVCs) are common arrhythmias associated with symptoms such as fatigue and, in severe cases, PVC-induced cardiomyopathy. Catheter ablation (CA) is a primary treatment for symptomatic PVCs, particularly when pharmacological therapies fail or are undesired. While improvements in: quality-of-life following ablation are documented, its impact on functional capacity remains underexplored. Objectives: This study evaluated the impact of CA on functional capacity and cardiac stress markers in patients with symptomatic PVCs using cardiopulmonary exercise testing (CPET) and NT-proBNP levels. Methods: A total of 30 patients underwent successful PVC ablation and completed baseline and follow-up CPET evaluations under the Bruce protocol. PVC burden, left ventricular ejection fraction (LVEF), NT-proBNP levels, and CPET parameters, including VO2 max, METS, ventilatory efficiency, and anaerobic threshold (AT), were analyzed pre- and post-ablation. Results: PVC burden significantly decreased post-ablation (23,509.3 ± 10,700.47 to 1759 ± 1659.15, p < 0.001). CPET revealed improved functional capacity, with VO2 max increasing from 24.97 ± 4.16 mL/kg/min to 26.02 ± 4.34 mL/kg/min (p = 0.0096) and METS from 7.16 ± 1.17 to 7.48 ± 1.24 (p = 0.0103). NT-proBNP significantly decreased (240.93 ± 156.54 pg/mL to 138.47 ± 152.91 pg/mL, p = 0.0065). LVEF and ventilatory efficiency metrics (VE/VO2 and VE/VCO2) remained stable. Conclusions: Catheter ablation improves functional capacity, reduces cardiac stress, and minimizes medication dependency in patients with symptomatic PVCs. These findings support the utility of ablation in enhancing aerobic capacity and overall exercise performance.