Pierfrancesco Pirri

Dr. Pierfrancesco Pirri


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GRGiuseppe Rovere
Giuseppe Rovere
PPPierfrancesco Pirri
Pierfrancesco Pirri
GMGianmarco Murgante
Gianmarco Murgante
VLVincenzo De Luna
Vincenzo De Luna
ATAurelio Testa
Aurelio Testa
FMFernando De Maio
Fernando De Maio
Distal radius fractures (DRFs) constitute one of the most prevalent injuries in adults. This study compares the clinical and radiological outcomes of intra- and extra-articular DRFs treated with percutaneous Kirschner wires (PKW) or volar locking plates (VLP). Materials and Methods: A retrospective analysis was conducted on 42 patients (aged 18 to 85) treated between 2017 and 2019 with a minimum follow-up of five years. Outcomes were assessed using radiographic parameters and validated clinical scoring systems such as Disabilities of the Arm, Shoulder, and Hand (DASH), Patient-Rated Wrist Evaluation (PRWE), and Mayo Wrist Score (MAYO). Results: Clinical outcomes were better in the VLP group but not statistically significant (p > 0.05). For extra-articular fractures, DASH were 1.5 (VLP) vs. 6.4 (PKW) (p = 0.5007), PRWE were 1.3 (VLP) vs. 2.9 (PKW) (p = 0.4049), and MAYO were 95 (VLP) vs. 86.1 (PKW) (p = 0.2406). For intra-articular fractures, DASH were 6.6 (VLP) vs. 19.7 (PKW) (p = 0.0981), PRWE 12.9 (VLP) vs. 21.1 (PKW) (p = 0.3661), and MAYO 78.9 (VLP) vs. 72.2 (PKW) (p = 0.4503). Conclusions: PKW and VLP showed satisfactory long-term outcomes. VLP fixation allowed better short-term recovery and anatomical restoration, but long-term functional outcomes were comparable.

Verified
Journal Article
Open access
PDF file
GRGiuseppe Rovere
Giuseppe Rovere
DLDavide Luziatelli
Davide Luziatelli
SLSandro Luziatelli
Sandro Luziatelli
GPGianluca Polce
Gianluca Polce
PPPierfrancesco Pirri
Pierfrancesco Pirri
FMFernando De Maio
Fernando De Maio
Introduction: Neck-preserving total hip arthroplasty (THA) has gained interest for conserving bone stock, restoring biomechanics, and facilitating revision surgery. The Nanos® femoral stem, designed for metaphyseal fixation while preserving the femoral neck, represents a reliable alternative to conventional THA. This study reports 15-year clinical and radiographic outcomes of the Nanos implant. Materials and Methods: We retrospectively reviewed 53 patients (35 males, 18 females) who underwent THA with the Nanos stem between 2008 and 2010. Patients were stratified into two groups according to age: <50 years (n = 24) and ≥50 years (n = 29). The primary diagnosis was osteoarthritis (95%), with a few cases of avascular necrosis or dysplasia. Clinical evaluation included the Harris Hip Score (HHS) and the Western Ontario and McMaster Universities Arthritis Index (WOMAC). Radiographic assessment focused on implant stability, osteolysis, and heterotopic ossifications. Kaplan–Meier survival analysis was performed with revision for any reason as the endpoint. Results: At 15 years of follow-up, both groups showed significant improvement (p < 0.001). In patients <50 years, HHS increased from 53.3 to 94.8 and WOMAC decreased from 79.9 to 3.5. In patients ≥50 years, HHS improved from 47.5 to 95.2 and WOMAC from 81.5 to 3.2. Radiographs confirmed stable fixation without osteolysis. Complications included two dislocations and one cortical perforation requiring revision. Kaplan–Meier survivorship at 15 years was 100% (<50) and 96.6% (≥50). Conclusions: The Nanos stem provided excellent long-term outcomes with low complication and revision rates. It should be considered one of several reliable short-stem options for younger, active patients, offering durable function while preserving bone stock.

Verified
Journal Article
Open access
PDF file
FLFrancesco Liuzza
Francesco Liuzza
PPPierfrancesco Pirri
Pierfrancesco Pirri
GSGianluca Serra
Gianluca Serra
AAAndrea Aureli
Andrea Aureli
FMFernando De Maio
Fernando De Maio
GRGiuseppe Rovere
Giuseppe Rovere
Background: Developmental dysplasia of the hip (DDH) is one of the leading causes of secondary hip osteoarthritis and frequently results in severe anatomical alterations that make total hip arthroplasty (THA) technically demanding. Restoration of hip biomechanics, limb length, and joint stability remains challenging, particularly in patients with moderate-to-severe dysplasia. Objective: To evaluate the clinical and radiographic outcomes of cementless total hip arthroplasty combined with soft-tissue balancing, with or without acetabular reconstruction using autologous femoral head graft, in patients affected by osteoarthritis secondary to DDH. Methods: A retrospective single-center case series was conducted on eight female patients (mean age 53.9 ± 14.6 years; range 33–80 years) who underwent primary cementless THA for DDH-related osteoarthritis between 2019 and 2025. Clinical outcomes were assessed using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Short Form-36 (SF-36). Radiographic evaluation included implant positioning, osteolysis, heterotopic ossification, bone graft incorporation, and leg-length discrepancy. Data normality was assessed using the Shapiro–Wilk test. Preoperative and postoperative outcomes were compared using paired Student’s t-test and confirmed with the Wilcoxon signed-rank test. Implant survival and revision-free status were recorded throughout the follow-up period. Results: At a minimum follow-up of 12 months (range 12 months–6 years), significant improvements were observed in all clinical outcome measures. Mean HHS increased from 49.3 ± 2.5 preoperatively to 90.4 ± 2.7 postoperatively (p < 0.001), while mean WOMAC decreased from 53.5 ± 5.6 to 7.4 ± 3.3 (p < 0.001). Mean SF-36 improved from 47.2 ± 3.8 to 89.9 ± 3.2 (p < 0.001). Wilcoxon analysis confirmed the statistical significance of these findings (all p = 0.0078). Radiographic assessment demonstrated satisfactory implant positioning and stable fixation in all patients, with no evidence of osteolysis or implant loosening. Minor complications included one intraoperative periprosthetic femoral fracture treated successfully with cerclage wiring, two cases of Brooker grade I–II heterotopic ossification, and one case of minimal graft resorption without clinical consequences. No revision procedures were recorded during follow-up, and implant survival was 100%. Conclusions: Cementless THA combined with selective soft-tissue balancing provides excellent clinical, functional, and radiographic outcomes in patients with osteoarthritis secondary to DDH. This approach significantly improves hip function and quality of life while ensuring stable implant fixation, low complication rates, and excellent mid-term implant survival.

22 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GRGiuseppe Rovere
Giuseppe Rovere
DLDavide Luziatelli
Davide Luziatelli
SLSandro Luziatelli
Sandro Luziatelli
GSGiacomo Sbriccoli
Giacomo Sbriccoli
LMLuca Mancini
Luca Mancini
FMFernando De Maio
Fernando De Maio
Background: Hip resurfacing arthroplasty (HRA) was developed as a bone-preserving alternative to conventional total hip arthroplasty (THA), particularly for young and physically active patients. However, concerns regarding metal-on-metal bearings have substantially restricted its use. This study evaluated the long-term clinical, functional, radiographic, and implant survivorship outcomes of HRA. Methods: This retrospective cohort study included all 53 consecutive primary HRA procedures performed at a single institution between January 2001 and December 2010. No patients were excluded or lost to follow-up. The mean age at surgery was 43.2 years (range, 18–56 years), and the mean follow-up was 20 years (range, 15–25 years). Clinical outcomes were assessed using the Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Paired preoperative and final scores were analyzed only in the 47 patients who retained their HRA implant. Radiographic evaluation included implant fixation, radiolucent lines, osteolysis, component alignment, and heterotopic ossification. Implant survivorship was estimated using the Kaplan–Meier method, with revision of any component for any reason as the endpoint. Results: Among the 47 patients with retained HRA implants, the mean HHS increased from 31.3 ± 17.9 preoperatively to 95.3 ± 7.4 at final follow-up, while the mean total WOMAC score decreased from 65.9 ± 10.4 to 11.5 ± 3.5 (both p < 0.001). Six hips (11.3%) underwent revision to conventional THA: three for metallosis, two for femoral neck fracture, and one for persistent pain associated with acetabular radiolucency. One additional patient developed postoperative thrombophlebitis that did not require implant revision. Radiographic assessment of unrevised hips demonstrated stable component fixation without progressive radiolucency, clinically significant osteolysis, implant migration, or aseptic loosening. Kaplan–Meier implant survivorship was 88.7% (95% confidence interval, 76.5–94.8%) at approximately 20 years. Conclusions: In this selected cohort of predominantly young and active patients, HRA provided substantial long-term clinical improvement, with an HHS of 95.3 ± 7.4, a WOMAC score of 11.5 ± 3.5, and implant survivorship of 88.7% at approximately 20 years. Nevertheless, the 11.3% revision rate and complications associated with metal-on-metal bearings support restricting HRA to carefully selected patients and maintaining long-term clinical, radiographic, and metal-ion surveillance.