Ranj Azad Omer

Dr. Ranj Azad Omer

Prosthodontics, Hawler Medical University, Erbil, Arbīl, Iraq
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2023 in Journal of Baghdad College of Dentistry
Verified
Journal Article
Open access
PDF file
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
HAHoshang Kh. Abdel-Rahman
Hoshang Kh. Abdel-Rahman
MSMahabad M. Saleh
Mahabad M. Saleh
SASazgar S.Q. Al-Hawezi
Sazgar S.Q. Al-Hawezi
FIFahd S. Ikram
Fahd S. Ikram
Most dental works require a diagnostic impression; alginate is contemplated as the most popular material used for this purpose. Titanium dioxide nanoparticles show evidence of antimicrobial activity in the recent era, for this purpose, this study aimed to evaluate the effect of adding Titanium dioxide nanoparticles on antimicrobial activity and surface detail reproduction of alginate impression material. Materials and methods: Titanium dioxide nanoparticles (purity = 99%, size= 20nm) was added to alginate at three different concentrations (2%, 3% and 5%). 84 samples were prepared in total. Samples were tested for antimicrobial activity using a disc diffusion test, and surface detail reproduction was done using (ISO 21563:2021). One-way ANOVA and independent sample t-test were used for data analysis through SPSS software. Results: for the antimicrobial test, inhibition zones for Streptococcus mutans and Candida albicans showed significant changes concerning the alteration in Titanium dioxide nanoparticle concentrations. The inhibition zone significantly increased with an increase in the percentage of Titanium dioxide nanoparticles. The mean of the inhibition zone for S. mutans was superior to C. albicans and the difference was statistically significant. Regarding surface detail reproduction, the control group, 2% and 3% groups manifested very similar results, only the group to which 5% of Titanium dioxide nanoparticles were added showed a decline in detail reproduction when compared to the other three groups. Conclusion: Within the limitation of this study, we can conclude that the antimicrobial activity against S mutans and C. albicans were significantly increased in modified groups, and this escalation was directly linked to the increase in Titanium dioxide nanoparticles concentration. In contrast, the surface detail reproduction was decreased when adding 5% Titanium dioxide nanoparticles to alginate.

6 December 2019 in Erbil Dental Journal
Verified
Journal Article
Open access
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
FIFahd S. Ikram
Fahd S. Ikram
Background and objectives: Heat cure denture base material is the most commonly used material for fabrication of removable prosthesis since its introduction in 1937. The unresolved problem of frequent fracture is one of the main drawbacks when used in denture construction. The purpose of this study was to evaluate the influence of silver nanoparticles on flexural and impact strength of heat-polymerized resin. Materials and methods: Silver nanoparticles were impregnated at 1%, 3% and 5% by weight to the monomer of methyl methacrylate with the aid of probe sonicator. Afterward, they were mixed with the acrylic powder. Sixty samples were prepared in total to observe its influence on flexural and impact strength. Results: Flexural strength values revealed a statistically significant difference (p<0.05) among the three concentrations. The results indicated a 22% reduction in the mean value for 3% while 1% and 5% caused 20% and 21% decrease respectively when compared to control. Regarding impact test, it demonstrated a statistically significant difference only for 5% that caused a drastic drop in impact value by 41% in contrast to the control group. Conclusion: Within the limitations of this study, it can be concluded that the addition of silver nanoparticles caused a reduction in mechanical strength of heat cure acrylic except for 3% which caused a minor non-significant increase in impact strength. Considering the negative effect on mechanical strength and jeopardizing the aesthetic value for acrylic, it can’t be considered as a suitable additive to enhance the properties tested.

1 June 2022 in Sulaimani dental journal
Verified
Journal Article
Open access
HAHoshang Abdel-Rahman
Hoshang Abdel-Rahman
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
MSMahabad Saleh
Mahabad Saleh
SASazgar Al-Hawezi
Sazgar Al-Hawezi
FIFahd Ikram
Fahd Ikram
Objective: This study aimed to evaluate the effect of adding titanium dioxide nanoparticles (TiO2NPs) on Shore A hardness, Young’s modulus, and tear strength of alginate impression material. Methods: Each test consists of one control group (alginate without TiO2NPs), and three test groups (2%, 3%, and 5%) of TiO2NPs were added, respectively. For each group, seven samples were constructed. For Shore A hardness, the samples were prepared according to ISO standards (7619-1:2010); Young’s modulus was calculated from the obtained Shore A hardness value according to a special standard equation. In contrast, for tear strength, the samples were prepared according to ASTM D 624-00. Results: The Control group exhibited a significantly less Shore A hardness value than all the other groups except the group that contained 2% TiO2NPs, where the increase in the hardness value was non-significant. A similar result was observed for Young’s modulus test, where the addition of TiO2NPs significantly increased Young’s modulus compared to the control group. Although, on the contrary, the tear strength was significantly improved by adding 3% TiO2NPs compared to control and other groups, there was a significant drop in the value of tear strength when 5% TiO2NPs were added to alginate. Conclusions: The addition of 3% TiO2NPs to dental alginate increased Shore A hardness, Young’s modulus, and significantly improved tear strength.

1 June 2019 in Sulaimani dental journal
Verified
Journal Article
Open access
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
FIFahd Ikram
Fahd Ikram
Objective: Heat cure acrylic is the most common used material for fabrication of dental prosthesis. This in vitro study was undertaken to discover the effect of nanoparticles on antibacterial properties of the denture base. Methods: Nanosized Silver and Copper oxide were impregnated at 1%, 3% and 5% by weight to the monomer of methyl methacrylate with the aid of probe sonicator before mixing it with acrylic powder. Seventy samples were prepared to determine the effect of the nanoparticles on Streptococcus mutans and Escherichia coli. Results: The results for Streptococcus mutans revealed a statistically significant difference (p<0.05) for both nanoparticles at the three concentrations except for 1% silver. The most influential concentration on the tested material was 3% copper oxide, which caused a 49% decline. Regarding Escherichia coli, only 3% and 5% of silver showed a statistically significant difference. Conclusions: Within the limitations of this in vitro study, it can be concluded that the addition of Silver nanoparticles into heat-cure acrylic was more effective against Streptococcus mutans than Escherichia coli. Regarding Copper oxide nanoparticles, it caused a drastic reduction in Streptococcus mutans activity but with no significant effect on Escherichia coli for all of its concentrations. Since denture stomatitis is caused by both bacterial species, Silver nanoparticles might be considered as a suitable additive for reducing denture induced infections.

1 December 2019 in Sulaimani dental journal
Verified
Journal Article
Open access
FIFahd Ikram
Fahd Ikram
JMJawad Mikaeel
Jawad Mikaeel
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
Objective: Elastic impression materials considered favourable decision in fixed and removable prosthesis due to ease of use and accuracy. High price tag is the main drawback. The purpose of this study was to evaluate surface detail reproduction and dimensional stability of newly introduced 3M Preliminary Penta™ VPS in comparison to other elastic impression. Methods: Alginate, alginate replacement and 3M light body were tested for surface detail reproduction and dimensional stability. Ten samples were prepared for each using a stainless-steel die that was created according to ADA specification No. 18 and 19. Surface detail was assessed directly after setting while dimensional stability was evaluated immediately and 24hr after. The data were analysed using a paired sample t-test. Results: All the samples were able to record 75μm line for surface detail. Surface record of 3M imprint™ 4 Preliminary Penta™ VPS showed a similar result to light body. While alginate failed to reproduce 50μm and 20μm lines. Regards to dimensional stability, light body resisted change with respect to time. In contrast, alginate revealed a significant effect (p˂0.05) on dimensional stability for the same storage period while not a major effect was observed for alginate replacement. Conclusions: Within the limitations of this study, it can be concluded that light body underwent less dimensional change than alginate and alginate replacement. It also revealed a better replication of details. Alginate replacement was more stable during the storage period with better surface detail record than alginate.

24 July 2026 in European Journal of Prosthodontics and Restorative Dentistry
Verified
Journal Article
Closed access
Ranj Azad OmerRanj Azad Omer
Ranj Azad Omer
ZAZhiyar Ameen Ali
Zhiyar Ameen Ali
With a focus on digital workflows, diagnostic assistance, and computer-aided design and manufacturing procedures, this narrative review examines current uses of artificial intelligence (AI) in prosthodontics. Relevant peer-reviewed research on clinically usable AI-driven techniques in fixed and removable prosthodontics that has been published recently was found in large scientific databases. An analysis of multiple peer-reviewed publications revealed that AI plays a significant role in the interpretation in prosthodontics (e.g., impressions, implant placement, and 3D designing) to support diagnosis and treatment planning. Clinically speaking, the evidence currently available supports the use of AI mainly as a decision-support tool in digital prosthodontic workflows, especially in margin detection and prosthetic design. However, routine clinical adoption of AI is still constrained by inadequate validation and practical applicability. Clinically speaking, the evidence currently available supports the use of AI mainly as a decision-support tool in digital prosthodontic workflows, particularly in margin detection and prosthetic design. However, routine clinical implementation of AI is still inhibited by inadequate validation and practical applicability. Aim of the Study The aim of this study is to systematically evaluate the assimilation of AI technologies in modern dentistry, quantifying their sway on diagnostic accuracy, treatment planning workflows, and clinic operational efficiency.