Khashayar Torabi-Farsani

Khashayar Torabi-Farsani

Power and Control Engineering Department, Shiraz University, Shīrāz, Fārs, Iran
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2019 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
MAMohammad Hassan Asemani
Mohammad Hassan Asemani
FBFarid Badfar
Farid Badfar
NVNavid Vafamand
Navid Vafamand
Mohammad Hassan KhoobanMohammad Hassan Khooban
Mohammad Hassan Khooban
This paper proposes a novel controller for the secondary load frequency control (LFC) of an alternating current shipboard microgrid (MG). The suggested controller is based on the robust μ-and mixed μ-synthesis in which the structured system uncertainties and external disturbance inputs are considered in the design procedure of the controller. The offline designed controller is resilient against the power fluctuations of the load and renewable energy sources (RESs), such as solar and wave energies. The output of the controller manipulates a diesel generator, as well as energy storage systems (ESSs) to effectively regulate the frequency of the AC MG to the desired value and reduce the frequency oscillations originated by the loads and RES power changes. Several hardware-in-the-loop (HiL) real-time dSPACE emulator-based simulations have been performed to show the effectiveness of the suggested robust control scheme. Additionally, comparison results are provided to better highlight the advantages of the proposed μ-synthesis-based approach over the state-of-the-art techniques.

19 December 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RARoozbeh Abolpour
Roozbeh Abolpour
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
MDMaryam Dehghani
Maryam Dehghani
NVNavid Vafamand
Navid Vafamand
MJMohammad Sadegh Javadi
Mohammad Sadegh Javadi
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
This paper addresses the topic of frequency regulation of a single-area power system connected to an electric vehicle (EV) aggregator over a non-ideal communication network. It is considered that the command control action is received by the EV aggregator with constant delay and the power system includes uncertain parameters. Due to the presence of uncertainties and the delay term, the frequency regulation problem is non-convex and hard to solve. The present approaches in the literature convert the non-convex control design problem into a convex problem with a set of Linear Matrix Inequalities (LMIs), which is conservative and in many cases results infeasibility. In this paper, an innovative iterative algorithm, called direct search, is employed for the time-delayed system to design the unknown parameters of a pre-assumed controller. The controller choice is not limited and various controllers' structures can be assumed. Without loss of generality, a proportional-integral (PI) controller is designed. The novel direct search algorithm can determine a feasible solution whenever at least one solution lays in the design space. Hence, by selecting a wide design space, we can anticipate that the PI controller guarantees closed-loop stability. Numerical simulations are carried out to demonstrate the performance of the developed controller compared to the state-of-the-art approach.

18 April 2022 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
NVNavid Vafamand
Navid Vafamand
Roozbeh Razavi-FarRoozbeh Razavi-Far
Roozbeh Razavi-Far
MSMehrdad Saif
Mehrdad Saif

7 September 2021
Verified
Conference Paper
Closed access
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
MDMaryam Dehghani
Maryam Dehghani
RARoozbeh Abolpour
Roozbeh Abolpour
NVNavid Vafamand
Navid Vafamand
MJMohammad S. Javadi
Mohammad S. Javadi
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
Nowadays, recent advances in information technology and communication facilitates using networked controlled systems in different industrial plants. Whereas data is transferred among different components of the networked systems, they are vulnerable to various types of attacks. This important issue in nowadays industrial plants should be treated logically and reasonable protection mechanisms to mitigate such attacks should be provided. This paper considers delay attack impacts on frequency regulation of an electric vehicle aggregator (EVA) system. The command control action is received by the EVA through an imperfect channel containing uncertainties subject to the time-delay attack. A systematic approach based on a direct search algorithm (DSA) is developed to design a resilient proportional-integral (PI) controller for mitigating such attacks. The proposed DSA provides low-conservative results, explores the design space to find a feasible solution, and computes the PI controller gains to assure the stability of the EVA system in the presence of the delay attack. Stability analysis and numerical simulations for a typical attacked EVA frequency regulation are given to show the effectiveness of the developed controller.

10 October 2021
Verified
Conference Paper
Closed access
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
MDMaryam Dehghani
Maryam Dehghani
RARouzbeh Abolpour
Rouzbeh Abolpour
NVNavid Vafamand
Navid Vafamand
MJMohammad Sadegh Javadi
Mohammad Sadegh Javadi
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
This paper investigates the issue of frequency regulation of a single-area alternating current (AC) power system connected to an electric vehicle (EV) aggregator through a nonideal communication network. It is assumed that the command control action is received by the EV aggregator with constant delay and the power system experiences uncertain parameters. A novel effective iterative algorithm, direct search, is proposed for the time-delayed system to design the gains of a proportional-integral (PI) controller. The proposed direct search algorithm can find a feasible solution whenever at least one solution lays in the space search. Thus, by choosing a wide space search, we can expect that the PI controller assures the closed-loop stability, theoretically. The proposed approach has low conservative results over the existing approaches. For the uncertain time-delayed system, a robust PI controller is designed, which is resilient against the system uncertainties and time delay. Numerical simulations are carried out to show the merits of the developed controller.

7 January 2025 in Journal of the Franklin Institute
Verified
Journal Article
Closed access
Khashayar Torabi-FarsaniKhashayar Torabi-Farsani
Khashayar Torabi-Farsani
MDMaryam Dehghani
Maryam Dehghani
RARoozbeh Abolpour
Roozbeh Abolpour