Rajul Gupta

Rajul Gupta

Auto-generated profile, based on publicly available information

Rajul Gupta


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
PPParimal Thakorbhai Patel
Parimal Thakorbhai Patel
KDKashish Dhal
Kashish Dhal
RGRajul Gupta
Rajul Gupta
Karthik TappaKarthik Tappa
Karthik Tappa
FRFrank Rybicki
Frank Rybicki
PRPrashanth Ravi
Prashanth Ravi
Medical 3D printing is a complex, highly interdisciplinary, and revolutionary technology that is positively transforming the care of patients. The technology is being increasingly adopted at the Point of Care (PoC) as a consequence of the strong value offered to medical practitioners. One of the key technologies within the medical 3D printing portfolio enabling this transition is desktop inverted Vat Photopolymerization (VP) owing to its accessibility, high quality, and versatility of materials. Several reports in the peer-reviewed literature have detailed the medical impact of 3D printing technologies as a whole. This review focuses on the multitude of clinical applications of desktop inverted VP 3D printing which have grown substantially in the last decade. The principles, advantages, and challenges of this technology are reviewed from a medical standpoint. This review serves as a primer for the continually growing exciting applications of desktop-inverted VP 3D printing in healthcare.

28 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SCShivum Manish Chokshi
Shivum Manish Chokshi
RGRaghav Gangatirkar
Raghav Gangatirkar
AKAnish Reddy Kandi
Anish Reddy Kandi
MDMaria DeLeonibus
Maria DeLeonibus
MKMohamed Kamel
Mohamed Kamel
PRPrashanth Ravi
Prashanth Ravi
Material Jetting (MJT) 3D printing (3DP) is a specific technology that deposits photocurable droplets of material and colored inks to fabricate objects layer-by-layer. The high resolution and full color capability render MJT 3DP an ideal technology for 3DP in medicine as evidenced by the 3DP literature. The technology has been adopted globally across the Americas, Europe, Asia, and Australia. While MJT 3D printers can be expensive, their ability to fabricate highly accurate and multi-color parts provides a lucrative opportunity in the creation of advanced prototypes and medical models. The literature on MJT 3DP has expanded greatly as of late, in part aided by the lowering costs of the technology, and this report is the first review to document the applications of MJT in medicine. Additionally, this report portrays the technological information behind MJT 3DP, cases involving fabricated MJT 3DP models from the University of Cincinnati 3DP lab, as well as the challenges of MJT in a clinical setting, including cost, expertise in managing the machines, and scalability issues. It is expected that MJT 3DP, as imaging and segmentation technologies undergo future improvement, will be best poised with representing the voxel-level-variations captured by radiologic-image-sets due to its capacity for voxel-level-control.

1 January 2018 in Indian Journal of Community Medicine
Verified
Journal Article
Open access
PDF file
RGRajul Kumar Gupta
Rajul Kumar Gupta
ARAparna Ruia
Aparna Ruia
GBGargi Bandyopadhyay
Gargi Bandyopadhyay
RGRajshree R Gupta
Rajshree R Gupta
Background: Good economic growth is considered synonymous with good nutrition. In recent past, some states (like Bihar and Gujarat) have seen unprecedented economic growth. Despite this and introducing plethora of programs (including integrated child development scheme [ICDS]) to reduce malnutrition, one state might be performing well in reducing malnutrition whereas other with equally high economic growth rate might lag behind. Is mere economic growth good enough to alleviate malnutrition? Objectives: The aim of the article is to document a critical comparative analysis of malnutrition with special emphasis on ICDS (with respect to finances, infrastructure, training, performance) in the two economically resurgent states of Gujarat and Bihar. Material and Methods: An exploratory study using secondary data sources (for ICDS performance) to critically analyze malnutrition status in Bihar and Gujarat. Results: Gujarat, which was criticized for placing excessive emphasis on economic growth, has shown sharp improvement in combating malnutrition. Undernourished children declined from 73.04% in 2007 to 25.09% in 2013, with just 1.6% being severely malnourished. On the other hand, Bihar too exhibited an impressive economic growth but still languishes at bottom with malnutrition rate of 82%. Conclusion: A high economic growth does not have automatic immediate positive gains on malnutrition alleviation.

19 April 2024
Verified
Book Chapter
Closed access
PDF file
SCShivum Manish Chokshi
Shivum Manish Chokshi
IHIbrahim Bin Huzaifa
Ibrahim Bin Huzaifa
ASAakanksha Sriwastwa
Aakanksha Sriwastwa
ASAdnan Sheikh
Adnan Sheikh
FRFrank J. Rybicki
Frank J. Rybicki
RGRajul Gupta
Rajul Gupta

1 December 2025 in RadioGraphics
Verified
Journal Article
Closed access
RGRajul Gupta
Rajul Gupta
ASAakanksha Sriwastwa
Aakanksha Sriwastwa
TKTim T. Klostermeier
Tim T. Klostermeier
PMPaul McMillan
Paul McMillan
BGBrian M. Grawe
Brian M. Grawe
SBSusan E. Braley
Susan E. Braley
Accurate imaging assessment of reverse total shoulder implants requires an understanding of implant biomechanics and the expected appearance of the components, as well as the spectrum of complications and modes of implant failure.

18 March 2026 in Journal of Pediatric Orthopaedics
Verified
Journal Article
Closed access
RGRajul Mbbs Gupta
Rajul Mbbs Gupta
ASAakanksha Sriwastwa
Aakanksha Sriwastwa
DLDiane Do Low
Diane Do Low
SPSaral Mbbs Patel
Saral Mbbs Patel
VJViral Jain
Viral Jain
SPShital N. Parikh
Shital N. Parikh
Background: Coronal-plane knee deformities, both genu varum and genu valgum, are common in pediatric orthopaedics and can be effectively managed in skeletally immature patients with guided growth techniques. Among these, percutaneous epiphysiodesis using transphyseal screws (PETS) and tension band plates (TBP) are widely used, yet their comparative effectiveness remains debated. Methods: A comprehensive search of PubMed, Embase, and Web of Science (January 2004 to January 2025) identified 603 studies. After applying the inclusion criteria, 13 studies (8 noncomparative and 5 comparative) were included in the analysis. Risk of bias was assessed using the ROBINS-I tool, and study quality was evaluated using the MINORS criteria. A frequentist random-effects meta-analysis was conducted to compare correction rates of mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and mechanical axis deviation (MAD). Results: PETS was effective, with correction rates for mLDFA, MPTA, and MAD ranging from 0.64 to 1.3 degrees/month, 0.52 to 0.86 degrees/month, and 1.3 to 3 mm/month, respectively. The meta-analysis showed faster correction with PETS compared to TBP: mLDFA (θ=0.71; P =0.05), MPTA (θ=0.60; P =0.06), and MAD (θ=0.80; P =0.11), although statistical significance was not reached. A meta-analysis of correction speed of mLDFA (θ=0.43; P =0.17) and MPTA (θ=0.6; P =0.06) in idiopathic patients did not show a significant difference, although faster correction with PETS was again observed. Conclusion: PETS is a reliable method for correcting coronal-plane deformities around the knee, with a tendency to achieve faster angular correction than TBP. Given the heterogeneity of included studies, further randomized controlled trials are needed to confirm these findings and guide implant choice based on patient-specific factors. Level of Evidence: Level III.