Rita Fidalgo-Pereira

Prof. Dr. Rita Fidalgo-Pereira

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
Rita Fidalgo-PereiraRita Fidalgo-Pereira
Rita Fidalgo-Pereira
OTOrlanda Araújo Lamas Correia Torres
Orlanda Araújo Lamas Correia Torres
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
Filipe SilvaFilipe Silva
Filipe Silva
Susana O. CatarinoSusana O. Catarino
Susana O. Catarino
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
In dentistry, clinicians mainly use dual-cured or light-cured resin-matrix cements to achieve a proper polymerization of the organic matrix leading to enhanced physical properties of the cement. However, several parameters can affect the polymerization of resin-matrix cements. The main aim of the present study was to perform a scoping review on the degree of conversion (DC) of the organic matrix, the polymerization, and the light transmittance of different resin-matrix cements used in dentistry. A search was performed on PubMed using a combination of the following key terms: degree of conversion, resin cements, light transmittance, polymerization, light curing, and thickness. Articles in the English language published up to November 2022 were selected. The selected studies’ results demonstrated that restorative structures with a thickness higher than 1.5 mm decrease the light irradiance towards the resin-matrix cement. A decrease in light transmission provides a low energy absorption through the resin cement leading to a low DC percentage. On the other hand, the highest DC percentages, ranging between 55 and 75%, have been reported for dual-cured resin-matrix cements, although the polymerization mode and exposure time also influence the DC of monomers. Thus, the polymerization of resin-matrix cements can be optimized taking into account different parameters of light-curing, such as adequate light distance, irradiance, exposure time, equipment, and wavelength. Then, optimum physical properties are achieved that provide a long-term clinical performance of the cemented restorative materials.

19 May 2025 in Gels
Verified
Journal Article
Open access
PDF file
MLMichela Lamorgese
Michela Lamorgese
NVNélio Veiga
Nélio Veiga
MCMaria José Correia
Maria José Correia
AGAna T. P. C. Gomes
Ana T. P. C. Gomes
SLSara Nunes Lopes
Sara Nunes Lopes
PLPedro Campos Lopes
Pedro Campos Lopes
White spot lesions (WSLs) are early clinical stages of enamel demineralization, often related to orthodontic treatment or poor oral hygiene. The use of gels such as fluoride for topical application inhibits demineralization and promotes remineralization of dental tissues through various mechanisms. A variety of therapeutic approaches are available; however, recent research indicates that combined treatment strategies may yield superior clinical outcomes compared to monotherapy. The aim of this study was to critically compare the efficacy of combining multiple treatment techniques for WSLs compared to using these techniques alone. A systematic search was conducted in PubMed, Scopus, and Cochrane databases according to PRISMA guidelines. The PICO strategy was used to formulate the research question: Which clinical approaches combined or isolated (C) influence the treatment and prevention effectiveness (O) of white spot lesions (I) in humans (P) in the last ten years (T)? Inclusion criteria focused on clinical studies from the last ten years evaluating the combined use of at least two treatment techniques for WSL, resulting in a total of 8 randomized controlled trials selected from an initial pool of 1185 articles. Our results suggest that combined treatment strategies, including resin infiltration with fluoride varnish and ozone therapy combined with fluoride application, demonstrated enhanced efficacy in lesion masking and remineralization compared to single-treatment approaches. CPP-ACP and hydroxyapatite-based creams improved aesthetics, particularly when used alongside fluoride varnish. Our study concluded that the combination of remineralization agents like fluoride gel, infiltrative resins, and antimicrobial treatments offers superior outcomes on white spot lesion treatment than using these techniques alone. However, long-term clinical studies are needed to standardize treatment protocols and confirm durability.

28 January 2022 in RevSALUS - Revista Científica da Rede Académica das Ciências da Saúde da Lusofonia
Verified
Journal Article
Open access
PDF file
Rita Fidalgo-PereiraRita Fidalgo-Pereira
Rita Fidalgo-Pereira
DCDaniela Minerva Evangelista Carpio
Daniela Minerva Evangelista Carpio
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
Susana O. CatarinoSusana O. Catarino
Susana O. Catarino
OTOrlanda Araújo Lamas Correia Torres
Orlanda Araújo Lamas Correia Torres
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
Introduction: In recent years, resin-matrix composite materials have revealed a fast technological improvement for dental applications. However, there are still some drawbacks related to the chemical composition, polymerization, and mechanical properties of resin-matrix composites with consequences in long-term clinical success. Objective: This study aimed to perform a narrative review regarding the effects of inorganic fillers on the organic matrix polymerization of resin-matrix composites. Materials and Methods: A search was performed in PubMed using relevant related key terms related to the chemical composition, properties and polymerization of resin matrix composites. Relevant studies published between 2001 and 2021 were selected. Results: The studies included in the present research provided relevant information on the chemical composition and properties of resin composites and polymerization factors, including the time, wavelength mode, and equipment. Studies have reported that silica and silicate nano-scale particles improve light transmission through resin-matrix composites and the degree of conversion of monomers in the organic matrix. Micrometric particles with a high refractive index can decrease the degree of conversion of monomers in the organic matrix. Conclusion: The polymerization of resin matrix composites is affected by light scattering due to the type of inorganic particles and the differences in refractive indexes of inorganic and organic contents.

15 March 2025 in Odontology
Verified
Journal Article
Open access
MCMaria Cordeiro
Maria Cordeiro
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
AGAna T. P. C. Gomes
Ana T. P. C. Gomes
PCPatrícia Correia
Patrícia Correia
Rita Fidalgo-PereiraRita Fidalgo-Pereira
Rita Fidalgo-Pereira
The aim of this study was to perform a systematic review to comprehensively explore the factors contributing to the resin-matrix composites′ toxicity in patients. A systematic review was performed according to the PRISMA guidelines. The bibliographic review was performed in the following databases: PubMed, Cochrane Central and Web of Science. Inclusion and exclusion criteria were established to retrieve articles published in English over the last 20 years. The research yielded 1261 articles, with 1227 articles remaining after removing duplicates. Following a title and abstract screening, 20 articles underwent full-text review, and 12 in vivo studies were included. Detectable levels of free monomers and potential toxicity exposure were reported in the selected studies on saliva, urine, and blood samples. The selected in vivo studies suggest relatively low local and systemic toxicity although the available methods show technical limitations and therefore further studies are required. Dental operator-dependent factors were also identified. Standard chair-side guidelines on handling of resin-matrix composites placement plays a key role on the properties of the materials. The results reported noticeable changes in samples were not considered significant to affect patient's health, although, manufacturer’s instructions must be followed whilst using resin-matrix composites. In fact, adequate light curing parameters maintain a high degree of conversion of the resin-matrix composites decreasing the release of residual monomers and thus the probability of related toxicity.

28 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
Rita Fidalgo-PereiraRita Fidalgo-Pereira
Rita Fidalgo-Pereira
Susana O. CatarinoSusana O. Catarino
Susana O. Catarino
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
NVNélio Veiga
Nélio Veiga
OTOrlanda Torres
Orlanda Torres
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
The aim of this study was to evaluate the influence of the thickness of resin-matrix composite blocks manufactured by CAD-CAM on the light transmittance towards different resin-matrix cements or flowable composites. Sixty specimens of resin-matrix composite CAD-CAM blocks reinforced with 89 wt% inorganic fillers were cross-sectioned with 2 or 3 mm thicknesses. The specimens were conditioned with adhesive system and divided in groups according to the luting material, namely: two dual-cured resin-matrix cements, two traditional flowable resin-matrix composites, and one thermal-induced flowable resin-matrix composite. Specimens were light-cured at 900 mW/cm2 for 40s. Light transmittance assays were preformed using a spectrophotometer with an integrated monochromator before and after light-curing. Microstructural analysis was performed by optical and scanning electron microscopy (SEM). Nanoindentation tests were performed to evaluate mechanical properties for indirect evaluation of degree of monomers conversion. Optical and SEM images revealed low thickness values for the cementation interfaces for the traditional flowable resin-matrix composite. The cement thickness increased with the size and content of inorganic fillers. The highest light transmittance was recorded for the onlay blocks cemented with the traditional flowable resin-matrix composites while a group cemented with the dual-cured resin-matrix cement revealed the lowest light transmittance. The elastic modulus and hardness increased for specimens with high content of inorganic fillers as well as it increased in function of the light transmittance. The light transmittance of flowable resin-matrix composites was higher than that for resin-matrix cement after cementation to resin-matrix composites blocks. The type, size, and content of inorganic fillers of the luting material affected the thickness of the cement layer and light transmittance through the materials. On chair-side light curing, the transmission of visible light can be interfered by the chemical composition and viscosity of the luting materials. The increase in size and content of inorganic fillers of resin-matrix composites and luting materials can decrease the light transmittance leading to inefficient polymerization.

Verified
Journal Article
Open access
PDF file
TMTiago Magalhães
Tiago Magalhães
Rita Fidalgo-PereiraRita Fidalgo-Pereira
Rita Fidalgo-Pereira
OTOrlanda Araújo Lamas Correia Torres
Orlanda Araújo Lamas Correia Torres
ÓCÓscar Samuel Novais Carvalho
Óscar Samuel Novais Carvalho
Filipe SilvaFilipe Silva
Filipe Silva
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
Purpose: This study aimed to assess the layer thickness and microstructure of traditional resin-matrix cements and flowable resin-matrix composites at dentin and enamel to composite onlay interfaces after cementation on low loading magnitude. Materials and Methods: Twenty teeth were prepared and conditioned with an adhesive system for restoration with resin-matrix composite onlays manufactured by CAD-CAM. On cementation, tooth-to-onlay assemblies were distributed into four groups, including two traditional resin-matrix cements (groups M and B), one flowable resin-matrix composite (group G), and one thermally induced flowable composite (group V). After the cementation procedure, assemblies were cross-sectioned for inspection by optical microscopy at different magnification up to ×1000. Results: The layer thickness of resin-matrix cementation showed the highest mean values at around 405 µm for a traditional resin-matrix cement (group B). The thermally induced flowable resin-matrix composites showed the lowest layer thickness values. The resin-matrix layer thickness revealed statistical differences between traditional resin cement (groups M and B) and flowable resin-matrix composites (groups V and G) (p < 0.05). However, the groups of flowable resin-matrix composites did not reveal statistical differences (p < 0.05). The thickness of the adhesive system layer at around 7 µm and 12 µm was lower at the interfaces with flowable resin-matrix composites when compared to the adhesive layer at resin-matrix cements, which ranged from 12 µm up to 40 µm. Conclusions: The flowable resin-matrix composites showed adequate flowing even though the loading on cementation was performed at low magnitude. Nevertheless, significant variation in thickness of the cementation layer was noticed for flowable resin-matrix composites and traditional resin-matrix cements that can occur in chair-side procedures due to the clinical sensitivity and differences in rheological properties of the materials.